Thermo Products OH5-85DXE Cutaway view of fan section of a typical highboy furnace

Page 7

All installations and services must be performed by qualified service personnel.

Connect the return air plenum to the filter rack and slide the filter into place. Dimensions for adapting the return air plenum to the filter rack are provided (See Fig. 5).

Fig. 5: A typical filter rack and dimensions for the OH5-85DXE*** furnace.

PLEASE NOTE: While scribing the return air opening, the filter rack can be held in position by tape or similar temporary means.

Position the open end of the filter rack so as to provide access for filter replacement. Once the filter rack is positioned correctly, scribe a line along the inside of the securing flange on three of the sides. To scribe a line on the fourth side (the open end), use the open end support as a guide.

Remove the filter rack and cut the return air opening in the casing. Now the filter rack can be anchored to the furnace with screws or pop-rivets through the securing flange of the filter rack.

cWARNING: When cutting openings in the casing DO NOT CUT ANY SUPPORTING CLIPS OR ANGLES. Cut as close to the scribed line as possible, but do not cut the base clip or blower pan support angle. (See Fig. 6).

Fig. 6: Cutaway view of fan section of a typical highboy furnace.

Connect the return air plenum to the filter rack and slide the filter into place. Dimensions for adapting the return air plenum to the filter rack are provided on the bottom of the previous page.

4

Image 7
Contents OH5-85DXE OIL Fired FurnaceSafety Section Table of Contents Section Beginning From Rear FLUE/VENT II. General Instructions Read Before Start of InstallationCombustible Material NON-COMBUSTIBLE MaterialFlue DIA Gasket OH5-85DXE Venting Rotation of Front Flue ElbowTrim Collar Unit DIA. HoleFilters Mounted External to Furnace Duct WORK/AIR ConditioningCutaway view of fan section of a typical highboy furnace Limit Position and Location Burner InstallationRiello Mounting Plate Top view Burner insertion illustration LOW Fire Nozzle Size Input Rate EffectiveHeating BTU/HR Capacity High FireHeat Exchanger Cleaning Instructions Inspection Areas III. Users Information SectionStarting the Burner Location of the air filter on the typical highboy furnace Filter Cleaning and LocationCustomer APPENDIX-A Replacement Parts List APPENDIX-B Wiring Diagram