All installations and services must be performed by qualified service personnel.

E. LIMIT POSITION AND LOCATION

cWARNING: The predetermined limit locations on all of the Thermo Pride oil fired furnaces have been tested and approved by Thermo Products, LLC. Any attempt to relocate these safety controls or replace these safety controls with a control that is not approved, or is incompatible, may result in personal injury, substantial property damage or death.

The unit listed in the table below must have the fan and limit control installed at the time of unit installation.

TABLE 2: Installation location of the fan and limit control for each furnace

Fig. 7: Limit location for OH5-85DXE***

F. BURNER INSTALLATION:

The oil burner will mount on three stud mounting bolts on the lower mounting plate covering the opening in the front of the heat exchanger. The end of the burner tube should be inserted no further than 1/4 inch back from the inside surface of the combustion chamber. A distance further than 1/4 inch back from the inside chamber wall may cause impingement and sooting.

NOTE: OVERFIRE AIR TAP MAY BE LOCATED ON EITHER SIDE OF FLAME INSPECTION COVER. (See Fig. 8).

RIELLO MOUNTING PLATE

Fig. 8: Typical location of the overfire air tap

5

Image 8
Contents OIL Fired Furnace OH5-85DXESafety Section Table of Contents Section Beginning II. General Instructions Read Before Start of Installation Combustible MaterialNON-COMBUSTIBLE Material From Rear FLUE/VENTVenting Rotation of Front Flue Elbow Trim CollarUnit DIA. Hole Flue DIA Gasket OH5-85DXEDuct WORK/AIR Conditioning Filters Mounted External to FurnaceCutaway view of fan section of a typical highboy furnace Riello Mounting Plate Burner InstallationLimit Position and Location Top view Burner insertion illustration Nozzle Size Input Rate Effective HeatingBTU/HR Capacity High Fire LOW FireHeat Exchanger Cleaning Instructions Starting the Burner III. Users Information SectionInspection Areas Filter Cleaning and Location Location of the air filter on the typical highboy furnaceCustomer APPENDIX-A Replacement Parts List APPENDIX-B Wiring Diagram