Thermo Products omd-70 service manual Iii. Furnace Specifications, Model, GMD-85

Page 10

All installations and services must be performed by qualified service personnel.

III. FURNACE SPECIFICATIONS

 

MODEL

OMD-70

GMD-85

HEAT INPUT RATE (BTUH)

85,000

85,000

HEATING CAPACITY (BTUH)

71,000

69,700

BURNER NOZZLE (GPH X

 

 

 

ANGLE, HOLLOW CONE)

0.65X80A

-------

BURNER ORIFICE-NAT. GAS

---------

#17 DMS

BURNER ORIFICE-PROP. GAS

---------

#36 DMS

OIL PUMP PRESSURE (PSIG)

100

-------

GAS SUPPLY PRESSURE (IN.W.G.)

 

 

MINIMUM REQUIRED

 

 

 

PROPANE

---------

11

NATURAL

---------

4.5

MAXIMUM ALLOWED

 

 

 

PROPANE

---------

13.9

NATURAL

---------

13.9

GAS MANIFOLD PRESSURE (IN. W.G.)

 

PROPANE

---------

10 + 0.3

NATURAL

---------

3.5 + 0.3

VENT PIPE SIZE (INCHES)

 

4

4

DESIGN TEMPERATURE RISE (°F)

85

85

MINIMUM RETURN AIR TEMP. (°F)

55

55

SEASONAL EFFICIENCY

 

 

 

(AFUE*, %)

 

85

82

*AFUE - INCLUDES STEADY STATE THERMAL EFFICIENCY AND OFF CYCLE LOSSES.

ELECTRICAL RATINGS AND SETTINGS: ELECTRICAL SUPPLY: 120 VAC / 60HZ / 1 PHASE

MAXIMUM TIME DELAY TYPE FUSE OR HACR BREAKER RATING: 15 AMPS

TOTAL RATED CURRENT (AMPS): 11.3 (OMD), 6.81 (GMD)

NOMINAL HEAT ANTICIPATOR SETTING -- 0.2 mA (OMD), 0.8 mA (GMD)

DIMENSIONS & WEIGHTS:

CABINET: WIDTH - 18 IN., DEPTH - 24 IN., HEIGHT - 57 IN.

NO.70 MOBILE HOME BASE: WIDTH - 18 5/16 IN., DEPTH - 24¼ IN., HEIGHT - 4 IN.

WARM AIR DUCT: WIDTH – 12 IN., DEPTH – 12 IN., HEIGHT - 14 ¼ IN.

COTTAGE BASE: WIDTH – 18 3/16 IN., DEPTH - 24¼ IN., HEIGHT – 14¾ IN.

FILTER QUANTITY & SIZE: (2) @ 17 ¾ IN. x 13 ¾ IN. x 1 IN. EA.

APPROXIMATE SHIPPING WEIGHT: 240 LBS.

PRODUCT LISTED UNDER UL FILE NUMBER -- MP3241

9

Image 10
Contents GAS-FIREDOR OIL-FIREDFURNACE MODEL: OMD-70 INSTALLATION AND SERVICE MANUALFOR YOUR SAFETY DOWN FLOW & DIRECT VENT SEALED COMBUSTIONI. SAFETY SECTION If you do not follow these instructions exactly, a fire or explosion may result causing personal injury, loss of life or property damage Do not attempt to start the burner when All installations and services must be performed by qualified service personnel POWER SWITCH SECTION TABLE OF CONTENTSBEGINNING PAGE a. Combustible material b.Non-combustiblematerial MODELS OMD/GMDMODEL III. FURNACE SPECIFICATIONSGMD-85 BURNER DATA BLOWER DATAB. STANDARD CHIMNEY IV. INSTALLATION A. ROOF JACKC.FURNACE LOCATION Cottage Base Model: 01COT-BASE D. BASE INSTALLATIONCombustible Floor Base Model: 70-BASE Figure 1A1. Combustible Floor Base Model: 70-BASE 2. Cottage Base Model: OMCCOT-BASE IMPORTANT: Adequate combustion air must be provided under all circumstances. If the underside of the home is skirted or enclosed e.g. by an enclosed crawlspace, the combustion air intake should exit through the side of cottage base and terminate outside of the structure. All joints and seams of supply ducts and combustion air ducts must be closed with a sealing method suitable to the application conditions and temperatures e.g. using high temperature silicone caulk and/or aluminum tape E. ALCOVE INSTALLATION F. CLOSET INSTALLATIONG. COMBUSTION AIR The preferred location of the outside combustion air intake termination e.g. an optional stainless steel intake hood, part no.370183 is through the side of the structure, skirting or enclosure. An alternate termination location is under the structure in the skirted or crawlspace area providing a minimum of 50 square inches of free area exists around the perimeter for outside combustion air to be drawn through. NOTE: Combustion air cannot be drawn from the occupied space of the home Figure H. FUEL PIPING 2. Oil Tank and Piping OMD-70 All installations and services must be performed by qualified service personnel Figure J. ELECTRICAL WIRING 1.Electrical Branch Supply Circuit 4. BLOWER CONTROLLER INFORMATION FOR PSC MOTOR TERMINAL DEFINITIONS & FIELD WIRINGA. Inputs B. OutputsC. Operating Modes PSC TROUBLE SHOOTING DIAGNOSTIC FEATURES5. WIRING DIAGRAM K. BURNER INSTALLATION L.BURNER OPERATION AND ADJUSTMENT replacement parts for location identification. After the furnace is warmed up to a steady- state condition about 15 minutes, the final burner adjustment should be made using combustion instrumentation for measuring carbon dioxide CO2 or oxygen O2, carbon monoxide CO, smoke for oil furnaces, and stack temperature. In order to achieve the most efficient combustion possible, the following steps must be taken M. FLUE GAS COMBUSTION ANALYSIS BURNER COMBUSTION PARAMETERSV. DEALER MAINTENANCE A. TROUBLESHOOTINGOMD/GMD TROUBLESHOOTING FLOWCHART Note: Check diagnostic code through view portprior to removing doors Are the thermostat wires closed? If 120 VAC is After fuel valve opens, does the burner ignite? Has the high limit thermostat B.CAD CELL CHECKOUT PROCEDURE: OMD ONLY C.HEAT EXCHANGER CLEANING INSTRUCTIONSD. CLEANING OR REPLACING FLUE PIPES E. EXTENDED SHUTDOWN VI. USER INFORMATION SECTION A. WARNINGS AND CAUTIONSB. COMPONENT LOCATIONS Figure C. INSPECTION AREASINSTALLATION / SERVICE D.FILTER LOCATION AND CLEANINGE. CONTACT INFORMATION APPENDIX A. REPLACEMENT PARTS LIST