a. Combustible material:

All installations and services must be performed by qualified service personnel.

II.GENERAL INSTRUCTIONS AND CLEARANCES NOTE: READ THIS SECTION BEFORE STARTING INSTALLATION

1.The selection of a furnace heating capacity for a proposed installation should be based on a heat loss calculation made according to the manuals provided by the Air Conditioning Contractors of America (ACCA) or the American Society of Heating, Refrigeration and Air Conditioning Engineers, Inc. (ASHRAE).

2.The installer shall be familiar with and comply with all codes and regulations applicable to the installation of this heating appliance. In addition to the governing standards items a) through e) this appliance shall also comply with “CSA B139 for recommended installation practices” where applicable.

a.Federal Manufactured Home Constructions & Safety Standard (HUD Total 24, Part 280).

b.American National Standard (ANSI-119.2/NFPA-501C), for all recreational vehicle installations.

c.American National Standard (ANSI-Z223.1/NFPA-54), for all gas-fired furnaces.

d.American National Standard (ANSI-Z95.1/NFPA-31), for all oil-fired furnaces.

e.American National Standard Electric Code (ANSI-C1/NFPA-70), for all electrical field wiring.

The oil-fired furnace has been investigated under the UL 307A test standard and the gas-fired furnace under the UL 307B test standard. Both gas and oil fired units are listed by Underwriters Laboratories and described as, “For installation as central furnace special type for single story dwelling.”

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background: The area around the furnace must be kept free and clear of combustible materials, especially papers and rags.

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background: This furnace is not to be used as a construction heater.

1.Definitions of "combustible" and "non-combustible" materials as presented in the 1996 version of the National Fuel Gas Code, ANSI Z223.1-1996/NFPA 70-1996, are as follows:

a. Combustible material:

“...materials made of or surfaced with wood, compressed paper, plant fibers, or other materials that are capable of being ignited and burned. Such materials shall be considered combustible even though flameproofed, fire- retardant treated, or plastered.”

7

Image 8
Contents MODEL: OMD-70 INSTALLATION AND SERVICE MANUAL FOR YOUR SAFETYGAS-FIREDOR OIL-FIREDFURNACE DOWN FLOW & DIRECT VENT SEALED COMBUSTIONI. SAFETY SECTION If you do not follow these instructions exactly, a fire or explosion may result causing personal injury, loss of life or property damage Do not attempt to start the burner when All installations and services must be performed by qualified service personnel POWER SWITCH BEGINNING PAGE TABLE OF CONTENTSSECTION a. Combustible material b.Non-combustiblematerial MODELS OMD/GMDGMD-85 III. FURNACE SPECIFICATIONSMODEL BURNER DATA BLOWER DATAC.FURNACE LOCATION IV. INSTALLATION A. ROOF JACKB. STANDARD CHIMNEY D. BASE INSTALLATION Combustible Floor Base Model: 70-BASECottage Base Model: 01COT-BASE Figure 1A1. Combustible Floor Base Model: 70-BASE 2. Cottage Base Model: OMCCOT-BASE IMPORTANT: Adequate combustion air must be provided under all circumstances. If the underside of the home is skirted or enclosed e.g. by an enclosed crawlspace, the combustion air intake should exit through the side of cottage base and terminate outside of the structure. All joints and seams of supply ducts and combustion air ducts must be closed with a sealing method suitable to the application conditions and temperatures e.g. using high temperature silicone caulk and/or aluminum tape E. ALCOVE INSTALLATION F. CLOSET INSTALLATIONG. COMBUSTION AIR The preferred location of the outside combustion air intake termination e.g. an optional stainless steel intake hood, part no.370183 is through the side of the structure, skirting or enclosure. An alternate termination location is under the structure in the skirted or crawlspace area providing a minimum of 50 square inches of free area exists around the perimeter for outside combustion air to be drawn through. NOTE: Combustion air cannot be drawn from the occupied space of the home Figure H. FUEL PIPING 2. Oil Tank and Piping OMD-70 All installations and services must be performed by qualified service personnel Figure J. ELECTRICAL WIRING 1.Electrical Branch Supply Circuit 4. BLOWER CONTROLLER INFORMATION FOR PSC MOTOR TERMINAL DEFINITIONS & FIELD WIRINGA. Inputs B. OutputsC. Operating Modes PSC TROUBLE SHOOTING DIAGNOSTIC FEATURES5. WIRING DIAGRAM K. BURNER INSTALLATION L.BURNER OPERATION AND ADJUSTMENT replacement parts for location identification. After the furnace is warmed up to a steady- state condition about 15 minutes, the final burner adjustment should be made using combustion instrumentation for measuring carbon dioxide CO2 or oxygen O2, carbon monoxide CO, smoke for oil furnaces, and stack temperature. In order to achieve the most efficient combustion possible, the following steps must be taken M. FLUE GAS COMBUSTION ANALYSIS BURNER COMBUSTION PARAMETERSV. DEALER MAINTENANCE A. TROUBLESHOOTINGprior to removing doors Note: Check diagnostic code through view portOMD/GMD TROUBLESHOOTING FLOWCHART Are the thermostat wires closed? If 120 VAC is After fuel valve opens, does the burner ignite? Has the high limit thermostat B.CAD CELL CHECKOUT PROCEDURE: OMD ONLY C.HEAT EXCHANGER CLEANING INSTRUCTIONSD. CLEANING OR REPLACING FLUE PIPES E. EXTENDED SHUTDOWN VI. USER INFORMATION SECTION A. WARNINGS AND CAUTIONSB. COMPONENT LOCATIONS Figure C. INSPECTION AREASE. CONTACT INFORMATION D.FILTER LOCATION AND CLEANINGINSTALLATION / SERVICE APPENDIX A. REPLACEMENT PARTS LIST