SPX Cooling Technologies FSIG-TS-08A specifications Access and Safety, Cold Water Basin

Page 18

Marley / Sigma F Series CoolingTower / Specifications: Base

18

 

 

Specifications

 

Specification Value

9.0Access and Safety:

9.1

Single cell towers shall include a

The access doors on other towers may be unreasonably small.

 

33" (838 mm) wide by 61" (1.55 m)

Specifying the size of the door will cause those bidders to take

 

high molded FRP access door in one

exception, alerting you to a potential maintenance headache.

 

endwall casing for access to the inte-

Good maintenance practice requires periodic access to the top of

 

rior of the tower. Casing access door

 

shall be hinged and equipped with a

the tower to inspect the distribution basins, as well as the struc-

 

latch operable from both inside and

tural integrity of the fan deck, fan cylinder, and fan—especially

 

outside the tower. Multicell towers

the fan blade securing hardware. And there are no induced-draft

 

shall have an access door in both

cooling tower designs that are immune to this need! Please

 

endwalls, and shall include a hinged

beware of those manufacturers who suggest otherwise.

 

door in each transverse partition to

 

 

give free access through the tower.

 

9.2

The top of the tower shall be equipped

For the comfort and safety of your

 

with a sturdy 42" (1067 mm) high fiber-

operating personnel, the Sigma

 

glass guardrail system, complete with

F Series includes a ladder and

 

top rails, intermediate rails, and toe-

guardrail of the quality and

 

boards conforming to OSHA standards.

design indicated—and we

 

Guardrail posts shall be extensions of

strongly recommend that

 

the tower columns.

you require it of all bidders!

9.3

 

Portable ladders and other

One endwall of the tower shall be

“make-do” access means are

 

equipped with a 20" (508 mm) wide

inappropriate for equipment of

 

aluminum vertical ladder, supported

this size and complexity.

 

by hot-dip galvanized steel brackets

 

 

through-bolted to the endwall struc-

 

 

ture. Ladder shall rise from the cold

 

 

water basin level to the top of the fan

 

 

deck guardrail, and shall be designed

 

 

and installed in conformance with

 

 

OSHA standards. A horizontal-swing,

 

 

gravity-closing safety bar shall be pro-

 

 

vided across the ladder opening at the

 

 

fan deck.

 

10.0

Cold Water Basin:

 

10.1

A large galvanized, rectangular access

This basic specification assumes that the tower will be erected

 

door shall be located on both end

over a concrete basin at grade level. If the tower is to be installed

 

panels for entry into the cold water

on an elevated supporting platform, the stainless steel cold water

 

basin. Rectangular panels are shall be

collection basin indicated on page 20 should be included in the

 

provided for access to the fan plenum

specifications.

 

area to facilitate inspection and allow

 

 

maintenance to the fan drive system

 

10.2Concrete partitions, if required between cells in the cold water basin, shall be installed in accordance with manufacturer's drawings. Tower installer shall seal between tower cell partitions and basin cell partitions.

Image 18
Contents Marley Sigma F Series Cooling Tower Marley / Sigma F Series CoolingTower / Table of Contents Marley / Sigma F Series CoolingTower 13-6 TowerModel Sectionelevation 4 MAXPlan Tower Flow/Cell Dimensions Model Engineering Data Piping PlanSteel Basin End Elevation Steel Basin End ElevationSide Elevation Two-Speed Motors Variable Speed FanSound Control Keeping It Clean EnclosuresWater Treatment Marley / Sigma F Series CoolingTower / Specifications Base BaseThermal Performance Construction Fan Deck and Fan Cylinder Mechanical EquipmentFill, Louvers and Drift Eliminators Hot Water Distribution System CasingAccess and Safety Cold Water BasinScope of Work Cold Water Basin Options Stainless Steel Cold Water Basin Basin HeaterConvenience and Safety Options Fiberglass Stairway Wood StairwayLadder Extension Ladder Safety CagePlenum Walkway Hot Water Basin CoversAir Inlet Screens Appearance Options Architectural CasingCased Guardrail Control Options Control System Mechanical Equipment section when Marley Premium VFD System Vibration Limit Switch Miscellaneous Options Galvanized Steel LadderFire-Retardant Fiberglass Fiberglass LadderLow Noise Tower Fan Cylinder ExtensionSpecifications Specification Value West 129 Street Overland PARK, Kansas 66213 United States

FSIG-TS-08A specifications

SPX Cooling Technologies has established itself as a leader in providing innovative cooling solutions, and the FSIG-TS-08A is a shining example of their engineering excellence. This advanced cooling system is designed for a variety of industrial and commercial applications where efficient heat exchange is crucial for optimal performance.

One of the standout features of the FSIG-TS-08A is its highly efficient heat transfer capabilities. The unit utilizes a corrosion-resistant heat exchanger design that enhances thermal performance while reducing maintenance needs. This is crucial in environments where durability and longevity are paramount. The robust construction of the FSIG-TS-08A ensures that it can withstand harsh operating conditions while maintaining its efficiency over time.

Another key characteristic of the FSIG-TS-08A is its energy-saving capabilities. In an era where energy costs are continually rising, this cooling solution incorporates advanced technologies that optimize energy consumption, leading to significant cost savings. The design includes variable speed fans that automatically adjust their operation based on cooling demand, which minimizes energy usage without sacrificing performance.

Moreover, the FSIG-TS-08A is equipped with a user-friendly control system, allowing operators to easily monitor and manage the unit's performance. The integrated controls provide real-time data on system operation and efficiency, further enhancing operational reliability.

The FSIG-TS-08A also boasts a compact design, making it suitable for installation in spaces where traditional cooling solutions may not fit. Its streamlined footprint does not compromise its cooling capability, making it an ideal choice for a wide range of settings, including manufacturing plants, power generation facilities, and other industrial operations.

In terms of versatility, the FSIG-TS-08A can be customized to meet specific requirements based on the application. This adaptability empowers businesses to leverage the cooling system to meet their unique challenges effectively.

In summary, SPX Cooling Technologies' FSIG-TS-08A is a cutting-edge cooling solution combining efficiency, durability, and flexibility. With its advanced technologies, energy-saving features, and user-friendly controls, the FSIG-TS-08A is well-equipped to meet the demanding needs of today's industrial landscape. It is a testament to SPX's commitment to delivering high-quality, innovative products that help organizations improve their operational efficiency while reducing their environmental footprint.