SPX Cooling Technologies FSIG-TS-08A specifications 13-6, Tower, Model

Page 4

Marley / Sigma F Series CoolingTower / Engineering Data : Schematic

4

 

 

C

 

C

C

L COLUMN

C DIAMETER FAN

L COLUMN

COLUMNL

3"

 

A BAYS AT 4'-0" = L

 

 

W OUT-TO-OUT OF TOWER

3"

TOWER PLAN

Use this data for preliminary layouts only. Obtain current drawing from your Marley sales representative.

The UPDATE web-based selection software

available at spxcooling.com — provides Sigma F Series model recommendations based on customer's specific design requirements.

TOP OF

FAN CYLINDER

BFAN DECK

H

13'-6"

BASE OF

TOWER COLUMNS

ENDWALL ELAVATION

Tower

 

 

Dimensions

 

 

 

Model

W

L

H

 

A

B

C

 

 

 

 

 

 

 

 

F1211

29'-2"

16'-0"

19'-6"

 

4

6'-0"

144"

 

 

 

 

 

 

 

 

F1221

31'-2"

16'-0"

20'-6"

 

4

7'-0"

168"

 

 

 

 

 

 

 

 

F1231

31'-2"

20'-0"

20'-6"

 

5

7'-0"

168"

 

 

 

 

 

 

 

 

F1241

31'-2"

24'-0"

20'-6"

 

6

7'-0"

168"

 

 

 

 

 

 

 

 

F1251

35'-2"

24'-0"

20'-6"

 

6

7'-0"

216"

 

 

 

 

 

 

 

 

F1261

35'-2"

28'-0"

20'-6"

 

7

7'-0"

216"

 

 

 

 

 

 

 

 

NOTE

1Use this bulletin for preliminary layouts only. Obtain current drawings from your Marley representative.

2All table data is per cell.

3All tower installations require a minimum of 4'-0" from cen- terline of tower endwall column to any vertical obstruction at tower ladder location. Ladder can be located at any corner of the fan deck. Ladder extends 838" below the base of tower

columns on applications with a stainless steel cold water basin. Ladder stops at top of basin curb wall on applications with a concrete basin.

Tower installations with an elevation 20'-0" or more from the top of the fan deck to grade or roof level require a safety cage on the tower ladder in compliance with OSHA standards. Marley ladder safety cages are available as an option.

Image 4
Contents Marley Sigma F Series Cooling Tower Marley / Sigma F Series CoolingTower / Table of Contents Marley / Sigma F Series CoolingTower Tower 13-6Model Sectionelevation 4 MAXPlan Tower Flow/Cell Dimensions Model Engineering Data Piping PlanSteel Basin End Elevation Steel Basin End ElevationSide Elevation Two-Speed Motors Variable Speed FanEnclosures Sound Control Keeping It CleanWater Treatment Marley / Sigma F Series CoolingTower / Specifications Base BaseThermal Performance Construction Fan Deck and Fan Cylinder Mechanical EquipmentFill, Louvers and Drift Eliminators Hot Water Distribution System CasingAccess and Safety Cold Water BasinScope of Work Cold Water Basin Options Stainless Steel Cold Water Basin Basin HeaterConvenience and Safety Options Fiberglass Stairway Wood StairwayLadder Safety Cage Plenum WalkwayLadder Extension Hot Water Basin CoversAppearance Options Architectural Casing Air Inlet ScreensCased Guardrail Control Options Control System Mechanical Equipment section when Marley Premium VFD System Vibration Limit Switch Miscellaneous Options Galvanized Steel LadderFiberglass Ladder Low Noise TowerFire-Retardant Fiberglass Fan Cylinder ExtensionSpecifications Specification Value West 129 Street Overland PARK, Kansas 66213 United States

FSIG-TS-08A specifications

SPX Cooling Technologies has established itself as a leader in providing innovative cooling solutions, and the FSIG-TS-08A is a shining example of their engineering excellence. This advanced cooling system is designed for a variety of industrial and commercial applications where efficient heat exchange is crucial for optimal performance.

One of the standout features of the FSIG-TS-08A is its highly efficient heat transfer capabilities. The unit utilizes a corrosion-resistant heat exchanger design that enhances thermal performance while reducing maintenance needs. This is crucial in environments where durability and longevity are paramount. The robust construction of the FSIG-TS-08A ensures that it can withstand harsh operating conditions while maintaining its efficiency over time.

Another key characteristic of the FSIG-TS-08A is its energy-saving capabilities. In an era where energy costs are continually rising, this cooling solution incorporates advanced technologies that optimize energy consumption, leading to significant cost savings. The design includes variable speed fans that automatically adjust their operation based on cooling demand, which minimizes energy usage without sacrificing performance.

Moreover, the FSIG-TS-08A is equipped with a user-friendly control system, allowing operators to easily monitor and manage the unit's performance. The integrated controls provide real-time data on system operation and efficiency, further enhancing operational reliability.

The FSIG-TS-08A also boasts a compact design, making it suitable for installation in spaces where traditional cooling solutions may not fit. Its streamlined footprint does not compromise its cooling capability, making it an ideal choice for a wide range of settings, including manufacturing plants, power generation facilities, and other industrial operations.

In terms of versatility, the FSIG-TS-08A can be customized to meet specific requirements based on the application. This adaptability empowers businesses to leverage the cooling system to meet their unique challenges effectively.

In summary, SPX Cooling Technologies' FSIG-TS-08A is a cutting-edge cooling solution combining efficiency, durability, and flexibility. With its advanced technologies, energy-saving features, and user-friendly controls, the FSIG-TS-08A is well-equipped to meet the demanding needs of today's industrial landscape. It is a testament to SPX's commitment to delivering high-quality, innovative products that help organizations improve their operational efficiency while reducing their environmental footprint.