IBM manual Diagnostic error message tables, IBM xSeries 220 User’s Reference

Models: 220

1 148
Download 148 pages 12.73 Kb
Page 100
Image 100

Diagnostic error message tables

The following tables provide descriptions of the error messages that might appear when you run the diagnostic programs.

Attention: If diagnostic error messages appear that are not listed in the following tables, make sure that your server has the latest levels of BIOS, ServeRAID, and diagnostics microcode installed.

Code

Function

Result

Text message

Action

 

 

 

 

 

001

Core system

Failed

Processor board, ECC Test

Call for service.

 

 

 

 

 

 

 

 

System board

 

 

 

 

 

 

005

Video port

 

Processor and system boards

 

 

 

 

 

 

011

Serial port

 

Integrated serial port

 

 

 

 

 

 

014

Parallel port

 

Integrated parallel port

 

 

 

 

 

 

015

USB interface

Aborted

Can NOT test USB interface while it is in use.

1. Turn off the server.

 

 

 

Note: If you have a USB keyboard or mouse

2. Replace the USB

 

 

 

attached, you cannot run the diagnostic

keyboard and

 

 

 

program for the USB interface.

mouse with a

 

 

 

 

standard keyboard

 

 

 

 

and mouse.

 

 

 

 

3. Turn on the server.

 

 

 

 

4. Run the diagnostic

 

 

 

 

test again.

 

 

 

 

5. If the test still

 

 

 

 

aborts with no USB

 

 

 

 

devices attached,

 

 

 

 

follow Failed action

 

 

 

 

below.

 

 

 

 

 

 

 

Failed

System board

Call for service.

 

 

 

 

 

020

PCI interface

Failed

System board

Call for service.

 

 

 

 

 

030

SCSI interface

Failed

SCSI adapter in slot n failed register/counter/ power

Refer to the information

 

 

 

test

provided with the

 

 

 

(where n is the slot number of the failing adapter)

adapter for instructions.

 

 

 

 

 

 

 

 

If the problem persists,

 

 

 

 

call for service.

 

 

 

 

 

 

 

 

SCSI controller on system board failed

Call for service.

 

 

 

register/counter/power test

 

 

 

 

 

 

90 IBM® xSeries 220 User’s Reference

Page 100
Image 100
IBM manual Diagnostic error message tables, IBM xSeries 220 User’s Reference