IBM 220 manual Code, Function, Result, Text message, Action, Use the Cache Control

Models: 220

1 148
Download 148 pages 12.73 Kb
Page 104
Image 104

Code

Function

Result

Text message

 

 

Action

 

 

 

 

 

 

202

System cache

Aborted

Test setup error: BIOS cannot access VPD information

 

If your server does not

 

 

 

 

 

have the latest level

 

 

 

Test setup error: Corrupt DMI BIOS. Information in

 

 

 

 

 

BIOS installed, update

 

 

 

BIOS is not as expected

 

 

 

 

 

the BIOS to the latest

 

 

 

 

 

 

 

 

 

 

level and run the

 

 

 

 

 

diagnostic program

 

 

 

 

 

again.

 

 

 

 

 

If the problem persists,

 

 

 

 

 

call for service.

 

 

 

 

 

 

 

 

 

Test setup error: No L2 cache detected on

 

1. If your server does

 

 

 

microprocessor socket id xyz or BIOS setup problem

 

 

not have the latest

 

 

 

(where xyz identifies the microprocessor that is

 

 

level BIOS

 

 

 

 

 

installed, update

 

 

 

causing the error message)

 

 

the BIOS to the

 

 

 

 

 

 

latest level

 

 

 

Test setup error: Unknown hardware problem

 

 

 

 

 

 

 

 

 

 

 

associated with microprocessor in socket id xyz.

2.

Run the diagnostic

 

 

 

(where xyz identifies the microprocessor that is

 

 

program again.

 

 

 

3.

If the problem

 

 

 

causing the error message)

 

 

 

 

 

remains, replace the

 

 

 

 

 

 

 

 

 

 

 

 

failing processor.

 

 

 

 

 

If the problem persists,

 

 

 

 

 

call for service.

 

 

 

 

 

 

 

 

Failed

Microprocessor in socket ID xyz

1.

Reseat the

 

 

 

(where xyz identifies the microprocessor that is

 

 

identified

 

 

 

 

 

microprocessor.

 

 

 

causing the error message)

2.

If the problem

 

 

 

 

 

 

 

 

 

 

remains, replace the

 

 

 

 

 

 

microprocessor.

 

 

 

 

 

If the problem persists,

 

 

 

 

 

call for service.

 

 

 

 

 

 

 

 

Warning

Test setup error: Cache is disabled. Use system setup

 

Use the Cache Control

 

 

 

to enable before retrying the test

 

choice from the

 

 

 

 

 

Advanced Setup menu

 

 

 

 

 

to enable the cache.

 

 

 

 

 

If the problem persists,

 

 

 

 

 

call for service.

 

 

 

 

 

 

206

Diskette drive

Failed

Internal diskette drive bay

 

Call for service.

 

 

 

 

 

 

215

CD-ROM

Failed

On system board.

 

Call for service.

 

 

 

 

 

 

 

 

Aborted

The CD-ROM drive is not present.

 

Verify that the cables are

 

 

 

 

 

properly connected to

 

 

 

 

 

the CD-ROM drive. If

 

 

 

 

 

the problem persists,

 

 

 

 

 

call for service.

 

 

 

 

 

 

217

Hard disk drive

Failed

BIOS drive # n (where n is the drive bay number)

 

Call for service.

 

 

 

 

 

 

 

94 IBM® xSeries 220 User’s Reference

Page 104
Image 104