Error LED (on the | System board or | Cause | Action |
system board or | front panel LED |
|
|
front panel) | on |
|
|
|
|
|
|
On | VRM 1 or VRM 2 | One of the microprocessor VRMs has | 1. Check the microprocessor VRM |
| (system board) | failed, or a microprocessor VRM is | error LEDs on the system board. |
|
| installed in the wrong connector. | If a microprocessor VRM error |
|
|
| LED is on for a microprocessor |
|
|
| VRM connector that has a |
|
|
| terminator card installed instead |
|
|
| of a microprocessor, the |
|
|
| microprocessor VRMs are not |
|
|
| installed in the correct order. See |
|
|
| “Installing and removing a |
|
|
| microprocessor” on page 54 for |
|
|
| information about the correct |
|
|
| order for installing |
|
|
| microprocessor VRMs. |
|
|
| Otherwise, continue with the |
|
|
| next step. |
|
|
| 2. Turn off the server, reseat the |
|
|
| microprocessor VRM indicated |
|
|
| by the lit microprocessor VRM |
|
|
| error LED, and restart the server. |
|
|
| 3. If the problem persists, replace |
|
|
| the microprocessor VRM. |
|
|
| If the problem persists, have the |
|
|
| system serviced. |
|
|
|
|
On | System error | The diagnostic LEDs have detected a | 1. Check the error LEDs on the |
| (front panel) | system error. | system board to locate the failing |
|
|
| or incorrectly installed |
|
|
| component. |
|
|
| 2. Follow the instructions in this |
|
|
| table for replacing the failing |
|
|
| component or removing and |
|
|
| reinstalling the incorrectly |
|
|
| installed component. |
|
|
| If the problem persists, have the |
|
|
| system serviced. |
|
|
|
|
Off | None | The diagnostic LEDs have not | None |
|
| detected a system error. |
|
|
|
|
|