POST message |
|
|
| Description |
|
| |||
186 | A system board or hardware error occurred. | |||
| Action: | Call for service. | ||
|
| |||
187 | The VPD serial number is not set. | |||
| Action: | The system serial number is set in the VPD EEPROM at the time of manufacturing. | ||
|
|
| If the system board has been replaced, the system serial number will be invalid and | |
|
|
| should be set. From the main menu of the Configuration/Setup Utility program, | |
|
|
| select System Information, then select Product Data.If the problem persists, call for | |
|
|
| service. | |
|
| |||
188 | A vital product data (VPD) error occurred. | |||
| Action: | Call for service. | ||
|
| |||
189 | An attempt has been made to access the server with invalid passwords. After three incorrect | |||
| attempts, the server locks up; that is, the logon data fields are no longer available to the user. | |||
|
| |||
201 | An error occurred during the memory controller test. This error can be caused by: | |||
| • | Incorrectly installed memory | ||
| • | A failing memory module | ||
| • | A system board problem | ||
| Action: | 1. | If you just installed memory, verify that the new memory is correct for your | |
|
|
|
| server. Also verify that the memory is installed and seated correctly. |
|
|
| 2. | If the problem persists, call for service. |
|
| |||
229 | An error was detected in the L2 cache of one of the microprocessors. | |||
| Action: | 1. | If you just installed a microprocessor, verify that the microprocessor is installed | |
|
|
|
| and seated correctly. |
|
|
| 2. | If the problem persists, call for service. |
|
| |||
289 | An error occurred during POST memory tests, and a failing DIMM was disabled. | |||
| Note: |
| You can use the server with decreased memory. | |
| Action: | 1. | If you just installed memory, verify that the new memory is correct for your | |
|
|
|
| server. Also verify that the memory is installed and seated correctly. Start the |
|
|
|
| Configuration/Setup Utility program, and select Memory Settings from the |
|
|
|
| Advanced Setup menu to enable the DIMM. |
|
|
| 2. | If the problem remains, replace the failing DIMM. |
| If the problem persists, call for service. | |||
|
| |||
301 303 | An error occurred during the keyboard and keyboard controller test. These error messages also | |||
| might be accompanied by continuous beeping. | |||
| Action: | Ensure that: | ||
|
|
| 1. | Nothing is resting on the keyboard and pressing a key. |
|
|
| 2. | No key is stuck. |
|
|
| 3. | The keyboard cable is connected correctly to the keyboard and to the correct |
|
|
|
| connector on the server. |
| Running the diagnostic tests can isolate the server component that failed, but you must have your | |||
| system serviced. If the error message remains, call for service. | |||
| Note: |
| If you just connected a new mouse or other pointing device, turn off the server and | |
|
|
| disconnect that device. Wait at least 5 seconds; then, turn on the server. If the error | |
|
|
| message goes away, replace the device. | |
|
|
|
|
|