POST message |
| Description |
|
| |
00180500 | A PCI adapter ROM error occurred. | |
| Action: | Remove the PCI adapters. If you can start the server without the adapters, reinstall |
|
| each adapter one at a time and retest after each is reinstalled. When an adapter fails, |
|
| replace it. |
| If you cannot isolate and correct the problem, call for service. | |
|
| |
00180600 | A | |
| Action: | Remove the PCI adapter that has the PCI bridge. If you can start the server without |
|
| the adapter, reinstall and retest the adapter. If the adapter fails, replace it. |
| If you cannot isolate and correct the problem, call for service. | |
|
| |
00180700 | xxxxyyyy Planar PCI device does not respond or disabled by user. (Where xxxx is the PCI vendor | |
| ID and yyyy is the PCI device ID.) | |
| Action: | Start the Configuration/Setup Utility program, select Devices and I/O Ports, and |
|
| make sure that the device is enabled. If the problem persists, call for service. |
|
| |
00180800 | An unsupported PCI device is installed. | |
| Action: | Remove the PCI adapters. If you can start the server without the adapters, reinstall |
|
| each adapter one at a time and retest after each is reinstalled. When an adapter fails, |
|
| replace it. |
| If the problem persists, call for service. | |
|
|
|
00181000 | PCI error. |
|
| Action: | Remove the PCI adapters. If you can start the server without the adapters, reinstall |
|
| each adapter one at a time and retest after each is reinstalled. When an adapter fails, |
|
| replace it. |
| If the problem persists, call for service. | |
|
| |
01295085 | The ECC checking hardware test failed. | |
| Action: | Call for service. |
|
| |
01298001 | No update data is available for processor 1. | |
| Action: | Update the system BIOS to a level that supports the microprocessors installed in the |
|
| server. |
|
| |
01298002 | No update data is available for processor 2. | |
| Action: | Update the system BIOS to a level that supports the microprocessors installed in the |
|
| server. |
|
| |
01298101 | The update data for processor 1 is incorrect. | |
| Action: | Update the system BIOS to a level that supports the microprocessors installed in the |
|
| server. |
|
| |
01298102 | The update data for processor 2 is incorrect. | |
| Action: | Update the system BIOS to a level that supports the microprocessors installed in the |
|
| server. |
|
| |
01298200 | Microprocessor speed mismatch. | |
| Action: | The microprocessors installed do not run at the same speed; install microprocessors |
|
| with identical speeds. |
|
| |
I9990301 | A hard disk drive error occurred. | |
| Action: | Call for service. |
|
|
|
Table 13. POST error messages