IBM 220 manual Features and specifications

Models: 220

1 148
Download 148 pages 12.73 Kb
Page 12
Image 12
Features and specifications

Features and specifications

Table 1 provides a summary of the features and specifications of your xSeries 220 server.

Microprocessor:

Intel® Pentium® III microprocessor with MMX™ technology and SIMD extensions

256 KB* ECC, level-2 cache (min.)

133 MHz front-side bus (FSB)

Support for up to two microprocessors

Memory:

Standard: 128 MB*

Maximum: 4 GB*

Type: 133 MHz, ECC, SDRAM, registered DIMMs

Slots: 4 dual in-line

Drives standard:

Diskette: 1.44 MB

CD-ROM: 48X IDE

Supports hot-swap SCSI hard disk drives (some models)

Expansion bays:

Two 5.25-in. bays (one CD-ROM drive installed)

Two 3.5-in. bays (one diskette drive installed)

Three 3.5-in. slim bays available in drive cage (some models have a hard disk drive installed)

PCI expansion slots:

Three 33 MHz/64-bit

Two 33 MHz/32-bit

Power supply:

One 330 watt autosensing (115-230 V ac)

Video:

S3 video controller (integrated on system board)

Compatible with SVGA and

VGA

8 MB SDRAM video memory

Size:

Height: 470 mm (18.5 in.)

Depth: 508 mm (20 in.)

Width: 165 mm (6.5 in.)

Weight: approximately 19.5 Kg (43 lb.) when fully configured or 15.9 Kg (35 lb.) minimum

Integrated functions:

Ultra160 SCSI low voltage differential (LVD) controller

One 10BASE-T/100BASE-TX Intel Ethernet controller on the system board

Two serial ports

Parallel port

Two Universal Serial Bus (USB) ports

Keyboard port

Mouse port

IDE controller port

Video port

Acoustical noise emissions:

Sound power, idling: 5.1 bel maximum

Sound power, operating: 5.3 bel maximum

Environment:

Air temperature:

Server on: 10° to 35° C (50.0°

to 95.0° F). Altitude: 0 to 914 m (2998.7 ft)

Server on: 10° to 32° C (50.0°

to 89.6° F). Altitude: 914 m (2998.7 ft) to 2133 m (6998.0 ft)

Server off: 10° to 43° C (50.0° to 109.4° F). Maximum altitude: 2133 m (6998.0 ft)

Humidity:

Server on: 8% to 80%

Server off: 8% to 80%

Heat output:

Approximate heat output in British thermal units (Btu) per hour

Minimum configuration: 341 Btu (100 watts)

Maximum configuration: 1604 Btu (470 watts)

Electrical input:

Sine-wave input (50-60 Hz) required

Input voltage low range:

Minimum: 100 V ac

Maximum: 127 V ac

Input voltage high range:

Minimum: 200 V ac

Maximum: 240 V ac

Input kilovolt-amperes (kVA), approximately:

Minimum: 0.08 kVA

Maximum: 0.52 kVA

Table 1. Features and specifications

*KB equals approximately 1000 bytes. MB equals approximately 1000000 bytes. GB equals approximately 1000000000 bytes.

2 IBM® xSeries 220 User’s Reference

Page 12
Image 12
IBM 220 manual Features and specifications