9.If you are installing a microprocessor that has a speed of 933 MHz or higher, install a fan sink onto the microprocessor and connect the
Terminator card
VRM 2 (J12)
| Microprocessor |
| fan 1 (J2) |
| Microprocessor |
| fan 2 (J3 ) |
Microprocessor |
|
| VRM 1 |
Fan sink | (J42) |
|
a.Peel the plastic protective strip off the bottom of the fan sink. Make sure that the square of thermal material is still on the bottom of the fan sink.
b.Align and place the fan sink on top of the microprocessor.
c.Align and place the
d.Insert a small,
e.Press down and in with the screwdriver handle to snap the
f.Connect the
•If you installed the microprocessor in connector U11, connect the fan- sink power cable to connector J2.
•If you installed the microprocessor in connector U12, connect the fan- sink power cable to connector J3.
10.Place the terminator card in the
11.Install the VRM that is included in the microprocessor kit. Attention: Use of other VRMs might cause your server to overheat.
a.Center the VRM over the appropriate VRM connector:
(1) If you installed the microprocessor in connector U11, press down on the latches on either side of connector J12, and install the VRM in connector J12.