Code

Function

Result

Text message

Action

 

 

 

 

 

035

ServeRAID

Aborted

Test setup error: No ServeRAID adapter found on

Make sure that the

 

 

 

system board or PCI bus

ServeRAID adapter is

 

 

 

 

properly installed. If the

 

 

 

 

problem remains,

 

 

 

 

replace the ServeRAID

 

 

 

 

adapter. If the problem

 

 

 

 

persists, call for service.

 

 

 

 

 

 

 

Failed

Adapter in slot n; adapter/drive configuration error

Run the ServeRAID

 

 

 

(where n is the slot number of the failing adapter)

Configuration Utility.

 

 

 

 

 

 

 

 

If the problem remains,

 

 

 

Adapter in slot n; internal error

 

 

 

replace the ServeRAID

 

 

 

 

 

 

 

(where n is the slot number of the failing adapter)

adapter in slot n.

 

 

 

 

 

 

 

 

 

 

 

 

Logical drive m on adapter in slot n

 

 

 

 

(where m is the number of the failing logical drive

If the problem persists,

 

 

 

and n is the slot number of the adapter)

call for service.

 

 

 

 

 

 

 

 

On system board; internal error

Run the ServeRAID

 

 

 

 

Configuration Utility.

 

 

 

On system board; adapter/drive configuration error

 

 

 

 

 

 

 

 

If the problem persists,

 

 

 

Logical drive on system board adapter

 

 

 

 

call for service.

 

 

 

 

 

 

 

 

Adapter in slot n; memory allocation error

Call for service.

 

 

 

(where n is the slot number of the failing adapter)

 

 

 

 

 

 

 

 

 

On system board; memory allocation error

 

 

 

 

 

 

 

 

 

On system board; PCI configuration error

 

 

 

 

 

 

 

 

 

On system board; POST error

 

 

 

 

 

 

 

 

 

Adapter in slot n; POST error

Replace the ServeRAID

 

 

 

(where n is the slot number of the failing adapter)

adapter in slot n. If the

 

 

 

problem persists, call for

 

 

 

 

service.

 

 

 

Adapter in slot n; PCI configuration error

 

 

 

 

 

 

 

(where n is the slot number of the failing adapter)

 

 

 

 

 

 

 

 

 

SCSI drive on adapter in slot n, SCSI ID m

Check the cable and

 

 

 

(where n is the slot number of the adapter and m is

power connections on

 

 

 

the drive. If the problem

 

 

 

the SCSI ID of the drive)

persists, call for service.

 

 

 

 

 

075

Power supply

Failed

Voltage sensed by the system is out of range

Call for service.

 

 

 

 

 

Chapter 6. Solving problems 91

Page 101