Error code (hex) |
| Description |
|
| |
0x02 | Explanation: Bad node address (multicast address). | |
| Action: Make sure that the locally administered address is valid, if one is specified. The | |
| address can not be a multicast address. | |
|
| |
0x03 | Explanation: Failed | |
| Action: Make sure a cable is attached to the Ethernet connector. If the problem persists, call | |
| for service. | |
|
| |
0x0D | Explanation: Could not allocate enough memory for transmit queues. | |
| Action: | |
| 1. | From the Windows NT desktop, select Start |
| 2. | Select your IBM Ethernet adapter from the list. |
| 3. | Select Properties |
| 4. | Lower the resource values that apply to the transmit queue. |
|
| |
0x0E | Explanation: Could not allocate enough memory for receive queue. | |
| Action: | |
| 1. | From the Windows NT desktop, select Start |
| 2. | Select your IBM Ethernet adapter from the list. |
| 3. | Select Properties |
| 4. | Lower the resource values that apply to the receive queue. |
|
| |
0x0F | Explanation: Could not allocate enough memory for other structures. | |
| Action: | |
| 1. | From the Windows NT desktop, select Start |
| 2. | Select your IBM Ethernet adapter from the list. |
| 3. | Select Properties |
| 4. | Lower the value for the resource named in the message. |
|
| |
0x10 | Explanation: Did not find any Ethernet controllers. | |
| Action: Using the Configuration/Setup Utility, make sure that Ethernet is enabled. | |
|
| |
0x11 | Explanation: Multiple Ethernet controllers found, but none matched the required ID. | |
| Action: Using the Configuration/Setup Utility, make sure that Ethernet is enabled. | |
|
| |
0x13 | Explanation: Did not find any Ethernet controllers that matched the required subven/subdev. | |
| Action: Using the Configuration/Setup Utility, make sure that Ethernet is enabled. | |
|
| |
0x16 | Explanation: Single adapter found but multiple instances tried to load. | |
| Action: Using the Configuration/Setup Utility, make sure that Ethernet is enabled, and that | |
| the slot containing the IBM Netfinity 10/100 Ethernet Adapter or the IBM 10/100 EtherJet™ | |
| PCI adapter is enabled. | |
|
| |
0x17 | Explanation: Slot parameter not specified in the registry. | |
| Action: Remove the adapter driver and reinstall it. If the problem persists, call for service. | |
|
| |
All other 4- | Action: Call for service. | |
character |
|
|
hexadecimal codes
Table 19. NDIS (Windows NT or Windows 2000) driver messages for the Ethernet controller