SPX Cooling Technologies FSIG-TS-08A specifications Control Options Control System

Page 24

Marley / Sigma F Series CoolingTower / Specifications: Options

24

 

 

Specifications

Control Options

Control System:

5.7Add the following paragraphs in the Mechanical Equipment sec- tion: Each cell of the cooling tower shall be equipped with a UL listed control system in a NEMA 3R or 4X outdoor enclosure capable of control- ling single-speed or two-speed motors as required, and designed specifically for cooling tower applications. The panel shall include a main fused dis- connect with an external operating handle, lockable in the off position for safety. Across-the-line magnetic start- ers or solid state soft-start starters as required shall be controlled with a thermostatic or solid state tempera- ture controller. Door mounted selector switches shall be provided to enable automatic or manual control and wired for 120VAC control. Control circuit to be wired out to terminal blocks for field connection to a remote vibration switch and for access to extra 120VAC 50VA control power, overload trip alarms and remote temperature control devices. The temperature controller shall be adjustable for the required cold water temperature. If a thermostatic controller is used it shall be mounted on the side of the tower with the tem- perature sensing bulb installed in the cold water basin using a suspension mounting bracket. If a solid state tem- perature controller is used the control- ler will be door mounted on the control panel. The temperature controller will display two temperatures, one for outgoing water and the other for set point. Water temperature input shall be obtained using a three-wire RTD with dry well in the outlet water piping and wired back to the solid state tempera- ture controller in the control panel.

Specification Value

If it is your opinion that the control system for the cooling tower should be part of the tower manufacturer’s responsibility, we are in wholehearted agreement with you. Who better to determine the most efficient mode and manner of a tower’s operation—and to apply a system most compatible with it—than the designer and manufacturer of the cooling tower?

Image 24
Contents Marley Sigma F Series Cooling Tower Marley / Sigma F Series CoolingTower / Table of Contents Marley / Sigma F Series CoolingTower 13-6 TowerModel Sectionelevation 4 MAXPlan Tower Flow/Cell Dimensions Model Engineering Data Piping PlanSteel Basin End Elevation Steel Basin End ElevationSide Elevation Two-Speed Motors Variable Speed FanSound Control Keeping It Clean EnclosuresWater Treatment Marley / Sigma F Series CoolingTower / Specifications Base BaseThermal Performance Construction Fan Deck and Fan Cylinder Mechanical EquipmentFill, Louvers and Drift Eliminators Hot Water Distribution System CasingAccess and Safety Cold Water BasinScope of Work Cold Water Basin Options Stainless Steel Cold Water Basin Basin HeaterConvenience and Safety Options Fiberglass Stairway Wood StairwayLadder Safety Cage Plenum WalkwayLadder Extension Hot Water Basin CoversAir Inlet Screens Appearance Options Architectural CasingCased Guardrail Control Options Control System Mechanical Equipment section when Marley Premium VFD System Vibration Limit Switch Miscellaneous Options Galvanized Steel LadderFiberglass Ladder Low Noise TowerFire-Retardant Fiberglass Fan Cylinder ExtensionSpecifications Specification Value West 129 Street Overland PARK, Kansas 66213 United States

FSIG-TS-08A specifications

SPX Cooling Technologies has established itself as a leader in providing innovative cooling solutions, and the FSIG-TS-08A is a shining example of their engineering excellence. This advanced cooling system is designed for a variety of industrial and commercial applications where efficient heat exchange is crucial for optimal performance.

One of the standout features of the FSIG-TS-08A is its highly efficient heat transfer capabilities. The unit utilizes a corrosion-resistant heat exchanger design that enhances thermal performance while reducing maintenance needs. This is crucial in environments where durability and longevity are paramount. The robust construction of the FSIG-TS-08A ensures that it can withstand harsh operating conditions while maintaining its efficiency over time.

Another key characteristic of the FSIG-TS-08A is its energy-saving capabilities. In an era where energy costs are continually rising, this cooling solution incorporates advanced technologies that optimize energy consumption, leading to significant cost savings. The design includes variable speed fans that automatically adjust their operation based on cooling demand, which minimizes energy usage without sacrificing performance.

Moreover, the FSIG-TS-08A is equipped with a user-friendly control system, allowing operators to easily monitor and manage the unit's performance. The integrated controls provide real-time data on system operation and efficiency, further enhancing operational reliability.

The FSIG-TS-08A also boasts a compact design, making it suitable for installation in spaces where traditional cooling solutions may not fit. Its streamlined footprint does not compromise its cooling capability, making it an ideal choice for a wide range of settings, including manufacturing plants, power generation facilities, and other industrial operations.

In terms of versatility, the FSIG-TS-08A can be customized to meet specific requirements based on the application. This adaptability empowers businesses to leverage the cooling system to meet their unique challenges effectively.

In summary, SPX Cooling Technologies' FSIG-TS-08A is a cutting-edge cooling solution combining efficiency, durability, and flexibility. With its advanced technologies, energy-saving features, and user-friendly controls, the FSIG-TS-08A is well-equipped to meet the demanding needs of today's industrial landscape. It is a testament to SPX's commitment to delivering high-quality, innovative products that help organizations improve their operational efficiency while reducing their environmental footprint.