Roberts Gorden CRV-B-6, CRV-B-8 Protective Grille Installation 1 Silicone Cap Installation

Page 35

SECTION 8: OPTIONAL HEATER ACCESSORIES

8.8Protective Grille Installation

Step 8.8.1 Silicone Cap Installation

 

Silicone Cap

 

Grille

Description

Part Number

Grille Section

08050001

Finger

Grille End Cap

08050002

 

 

Silicone Cap

91915951-6P

Step 8.8.2 Grille End Cap Installation

A

B

Grille

Grille End Cap

C

D

 

Bend up 90°

 

Pull outward

Step 8.8.3 Grille Installation

Reflector

40"

(101 cm)

Final Grille

Section

Grille

Grille

End Cap

29

Image 35
Contents CoRayVac Page Roberts GORDON, LLC Page Table of Figures Page Manpower Requirements Heater SafetyNational Standards and Applicable Codes Installer ResponsibilityWall Tag Corrosive ChemicalsMaintain clearances to combustibles at all times for safety ONE Side Reflector Standard ReflectorUniversal SHIELD, Position Foot Deco Grille National Standards and Applicable Codes With Lock Coupling Assembly Tube AdapterMajor Components Reflector Side Aluminum or Stainless SteelRoberts Gordon Adjustable Indoor SensorRoberts Gordon Ultravac Variable Frequency DriveContents of CRV-Series Burner Carton Standard Parts ListProtective Grille Design Requirements Heater Assembly OverviewCritical Hanger Placement Heater InstallationCoupling and Tube Assembly Tube Installation± 2 5 cm 2 Elbow Installation2 Reflector Installation Reflector Installation 1 Reflector Installation with HoleScrew Wire Form Reflector Support Strap Burner Combustion Chamber Gasket End Vent Burner InstallationReflector Joint 1 Reflector Joint Installation Optional Heater AccessoriesTee Installation 3 Reflector Joint Detail 2 Reflector Joint Installation2 Side Reflector Installation Reflector Side Extension .3.1 Bracket InstallationBarrier Shield See Page 5, through Page 5, for positions2 Frame Shield Installation Decorative Grille Bracket 3 Joint Piece and Reinforcement 2 Decorative Grille4 End Piece and Reflector End Cap 3 Grille Installation Protective Grille Installation 1 Silicone Cap Installation2 Grille End Cap Installation Kg per foot Corayvac Classic Cast-Iron Adapter EP-200 Condensate Valve Assembly Pump Installation and Venting 9.1 Pump InstallationCanadian Requirements Vertical VentingHorizontal Venting United States RequirementsVertical Venting Configuration Horizontal Venting 4 10 cm Pipe EP-100 Horizontal Venting ConfigurationsEP-200 Series Horizontal Venting Configurations EP-300 Series Horizontal Venting Configurations Duct Design Rules Outside AIR SupplyNon-Pressurized PressurizedOutside Air Blower Internal Wiring Diagram Outside Air Blower Internal WiringAir Supply Blower Support Non-Pressurized Outside Air Supply Gas Connection with Flexible Gas Hose GAS PipingDpst Transformer Relay P/N Control MethodsRoberts Gordon System Control Roberts Gordon Ultravactm120 120 Two Zone Operation without Control Panel 60 Hz 12 Vdc 120 Ground 208 230 Burner Internal Wiring Checking the Electrical System Setting the VacuumStarting the System Checking the Gas LineVacuum Reading To Shut Off Heater Operation and MaintenancePre-Season Maintenance and Annual Inspection Sequence of OperationReflector Maintenance ChecklistInstallation Code and Annual Inspections Vehicles and Other ObjectsBlower Scroll, Wheel TubesGas Line WindowPump With the Power offStart ChartYes Follow burner check Procedure given above Troubleshooting FlowDescription Replacement PartsGAS Inlet Pressure General SpecificationsDimensions Pipe ConnectionEP-303 Pump Specifications Model EP-100Air Supply Blower Specifications EP-203Page Limitations on Authority Representatives Warranty is Void ifROBERTS-GORDON will not PAY for Page Owner Warranty Registration Card Page Page F r a r e d H e a t i n g
Related manuals
Manual 40 pages 12.87 Kb Manual 40 pages 29.7 Kb

CRV-B-4, CRV-B-12, CRV-B-2, CRV-B-10, CRV-B-6 specifications

The Roberts Gordon CRV-B-9 is a state-of-the-art infrared radiant heater designed for industrial and commercial heating applications. Renowned for its efficiency and effectiveness, the CRV-B-9 represents a significant advancement in the world of space heating solutions.

One of the main features of the CRV-B-9 is its advanced infrared technology, which allows for precise heating without the necessity of warming the entire space. This targeted heating provides immediate comfort, as it directly warms objects and people rather than the air around them, making it particularly effective in large warehouses, manufacturing facilities, and retail spaces.

The heater boasts an impressive output of up to 80,000 BTUs, making it suitable for a wide range of applications. It utilizes natural gas as fuel, which contributes to its efficiency and cost-effectiveness. With a robust design and durable construction, the CRV-B-9 is built to withstand the rigors of industrial environments while ensuring a long product lifespan.

Another significant characteristic of the CRV-B-9 is its ability to integrate with advanced control systems. This includes compatibility with programmable thermostats and energy management systems, allowing for optimized temperature control and reduced energy consumption. The heater can be adjusted to suit different operational needs, making it a flexible solution for various heating scenarios.

The CRV-B-9 also features a compact design, allowing for easy installation in a variety of spaces. Its low-profile shape and modular capability enable users to arrange multiple units to achieve the desired heating coverage without compromising floor space, a crucial aspect for busy, high-traffic areas.

Safety is a priority with the CRV-B-9, which is equipped with various safety features such as a flame safety cutoff switch and over-temperature protection. These mechanisms ensure safe operation, providing peace of mind for users in demanding environments.

In summary, the Roberts Gordon CRV-B-9 infrared radiant heater stands out for its innovative technology, impressive output, energy efficiency, and safety features. Its flexibility and robust design make it an ideal choice for businesses looking to enhance comfort while minimizing energy costs. Whether in a manufacturing plant or a retail outlet, the CRV-B-9 provides a reliable and effective heating solution.