Roberts Gorden CRV-B-9, CRV-B-8, CRV-B-6 Standard Parts List, Contents of CRV-Series Burner Carton

Page 17

SECTION 5: MAJOR COMPONENTS

5.1 Standard Parts List

Table 1: Contents of CRV-Series Burner Carton

Part No.

Description

0270XXXX

Burner (Rate and Fuel Varies)

*91412200

Flexible Stainless Steel Gas Hose, 1/2" NPT

 

(US models only)

013676XX

End Vent Plate

01397300

Accessory Package

01361200

Filter Support Disk

01367800

Combustion Chamber Gasket

02724901

Door Assembly w/ Hole

91115100

Screw #10 - 24 x 5/8

91119500

U-Clip

91905500

Filter Support

92123900

Nut 5/16 - 18

92511601

Wing Nut #10 - 24

96411600

Lock Washer 5/16"

01312401

Filter and Gasket

*Canadian Models: Rubber (Type 1) Gas Hoses available as an accessory, see Page 41.

Table 2: Common CRV-Series Components

Part No.

Description

Combustion Chamber:

02722300-1P Hot Rolled Steel Combustion Chamber

02722301-1P Heat-Treated Aluminized Steel Combustion Chamber

0272230D-1P Porcelain Coated Steel Combustion Chamber

02721200-1P Cast Iron Combustion Chamber

Tubing and Related Accessories

01312700 Coupling, 4" (10 cm) Plain

01312706 Coupling, 6" (15 cm) Plain

0131270I Coupling, 4" (10 cm) Lined

01331900 Coupling, 4" (10 cm) Damper

E0009356 Coupling, 6" (15 cm) Damper

0133022D Tee, 4" (10 cm) Coated

01330203 Tee, 4" (10 cm) Aluminized

01330204 Tee, 6" (15 cm) Aluminized

0133092D Cross, 4" (10 cm) Coated

01330903 Cross, 4" (10 cm) Aluminized

01330904 Cross, 6" (15 cm) Aluminized

01335801 Elbow, 4" (10 cm) Aluminized 90°

T0100320 Elbow, 6" (15 cm) Aluminized 90°

0133580D Elbow, 4" (10 cm) Coated 90°

01336101 Elbow, 4" (10 cm) Aluminized 45°

0133610D Elbow, 4" (10 cm) Coated 45°

91409300 Tube, Hot Rolled Steel 4" (10 cm) dia 10' (3 m)

91409403 Tube, Non-Heat Treated Aluminized 4" (10 cm) dia 10' (3 m)

91409408 Tube, Heat Treated Aluminized 4" (10 cm) dia 10' (3 m)

91409420 Tube, Non-Heat Treated Aluminized 6" (15 cm) dia 10' (3 m)

9141030D Tube, Coated 4" (10 cm) dia 10' (3 m)

E0009105 Tube, Heat Treated Aluminized 6" (15 cm) dia 10' (3 m)

91418200 Tube Adapter, Aluminized

6" (15 cm) dia x 4" (10 cm) dia

02722100

Adapter, 4" (10 cm) Cast Iron

91240010

Tube Hanger, 6" (15 cm)

91308001

High Temperature Pipe Compound, 1lb. can

 

 

 

Venting Accessories

01324401

Outside Air Supply Takeoff, 4" (10 cm)

01326801

Outside Air Filter Housing

90707501

Air Supply Blower/Power Venter

91409601

Outside Air Flex Duct, 4" (10 cm)

 

(Box of 8 - 8' [2.4 m] sections)

 

 

 

Reflectors and Related Accessories

01329910

Reflector Side Extension Support

03050010

Reflector Support Package (Tubing)

02712700

Reflector Side Extension, 2 Clips, 2 Screws

02716400

Reflector Support Package (Schedule 40 Pipe)

02750303

Reflector, Aluminum

027503SS

Reflector, Stainless Steel

02750304

Reflector, Aluminum with Hole

027503SH

Reflector, Stainless Steel with Hole

02750800

Reflector End Cap, Aluminum

027508SS

Reflector End Cap, Stainless Steel

027508SH

Reflector End Cap, Stainless Steel with Hole

02750900

Reflector Joint

027509SS

Reflector Joint, Stainless Steel

027127SS

Reflector Side Extension, Stainless Steel

03090100

Tube and Reflector Hanger

02790300

Tube and Reflector Hanger, Cast Iron

91907302

S-Hook

91903201

Turnbuckle

91903300

Spring Hook

91903202

Turnbuckle with Eyebolt

02712100

Universal Shield Support

02751800

Universal Shield with Holes

02751801

Universal Shield

027518SS

Universal Shield, Stainless Steel

11

Image 17
Contents CoRayVac Page Roberts GORDON, LLC Page Table of Figures Page Manpower Requirements Heater SafetyWall Tag Installer ResponsibilityCorrosive Chemicals National Standards and Applicable CodesMaintain clearances to combustibles at all times for safety ONE Side Reflector Standard ReflectorUniversal SHIELD, Position Foot Deco Grille National Standards and Applicable Codes With Lock Coupling Assembly Tube AdapterMajor Components Reflector Side Aluminum or Stainless SteelRoberts Gordon Ultravac Adjustable Indoor SensorVariable Frequency Drive Roberts GordonContents of CRV-Series Burner Carton Standard Parts ListProtective Grille Design Requirements Heater Assembly OverviewCritical Hanger Placement Heater InstallationCoupling and Tube Assembly Tube Installation± 2 5 cm 2 Elbow Installation2 Reflector Installation Reflector Installation 1 Reflector Installation with HoleScrew Wire Form Reflector Support Strap Burner Combustion Chamber Gasket End Vent Burner InstallationReflector Joint 1 Reflector Joint Installation Optional Heater AccessoriesTee Installation 3 Reflector Joint Detail 2 Reflector Joint Installation2 Side Reflector Installation Reflector Side Extension .3.1 Bracket InstallationBarrier Shield See Page 5, through Page 5, for positions2 Frame Shield Installation Decorative Grille Bracket 3 Joint Piece and Reinforcement 2 Decorative Grille4 End Piece and Reflector End Cap 3 Grille Installation Protective Grille Installation 1 Silicone Cap Installation2 Grille End Cap Installation Kg per foot Corayvac Classic Cast-Iron Adapter EP-200 Condensate Valve Assembly Pump Installation and Venting 9.1 Pump InstallationHorizontal Venting Vertical VentingUnited States Requirements Canadian RequirementsVertical Venting Configuration Horizontal Venting 4 10 cm Pipe EP-100 Horizontal Venting ConfigurationsEP-200 Series Horizontal Venting Configurations EP-300 Series Horizontal Venting Configurations Non-Pressurized Outside AIR SupplyPressurized Duct Design RulesOutside Air Blower Internal Wiring Diagram Outside Air Blower Internal WiringAir Supply Blower Support Non-Pressurized Outside Air Supply Gas Connection with Flexible Gas Hose GAS PipingRoberts Gordon System Control Control MethodsRoberts Gordon Ultravactm Dpst Transformer Relay P/N120 120 Two Zone Operation without Control Panel 60 Hz 12 Vdc 120 Ground 208 230 Burner Internal Wiring Starting the System Setting the VacuumChecking the Gas Line Checking the Electrical SystemVacuum Reading Pre-Season Maintenance and Annual Inspection Operation and MaintenanceSequence of Operation To Shut Off HeaterInstallation Code and Annual Inspections Maintenance ChecklistVehicles and Other Objects ReflectorGas Line TubesWindow Blower Scroll, WheelPump With the Power offStart ChartYes Follow burner check Procedure given above Troubleshooting FlowDescription Replacement PartsDimensions General SpecificationsPipe Connection GAS Inlet PressureAir Supply Blower Specifications Pump Specifications Model EP-100EP-203 EP-303Page Limitations on Authority Representatives Warranty is Void ifROBERTS-GORDON will not PAY for Page Owner Warranty Registration Card Page Page F r a r e d H e a t i n g
Related manuals
Manual 40 pages 12.87 Kb Manual 40 pages 29.7 Kb

CRV-B-4, CRV-B-12, CRV-B-2, CRV-B-10, CRV-B-6 specifications

The Roberts Gordon CRV-B-9 is a state-of-the-art infrared radiant heater designed for industrial and commercial heating applications. Renowned for its efficiency and effectiveness, the CRV-B-9 represents a significant advancement in the world of space heating solutions.

One of the main features of the CRV-B-9 is its advanced infrared technology, which allows for precise heating without the necessity of warming the entire space. This targeted heating provides immediate comfort, as it directly warms objects and people rather than the air around them, making it particularly effective in large warehouses, manufacturing facilities, and retail spaces.

The heater boasts an impressive output of up to 80,000 BTUs, making it suitable for a wide range of applications. It utilizes natural gas as fuel, which contributes to its efficiency and cost-effectiveness. With a robust design and durable construction, the CRV-B-9 is built to withstand the rigors of industrial environments while ensuring a long product lifespan.

Another significant characteristic of the CRV-B-9 is its ability to integrate with advanced control systems. This includes compatibility with programmable thermostats and energy management systems, allowing for optimized temperature control and reduced energy consumption. The heater can be adjusted to suit different operational needs, making it a flexible solution for various heating scenarios.

The CRV-B-9 also features a compact design, allowing for easy installation in a variety of spaces. Its low-profile shape and modular capability enable users to arrange multiple units to achieve the desired heating coverage without compromising floor space, a crucial aspect for busy, high-traffic areas.

Safety is a priority with the CRV-B-9, which is equipped with various safety features such as a flame safety cutoff switch and over-temperature protection. These mechanisms ensure safe operation, providing peace of mind for users in demanding environments.

In summary, the Roberts Gordon CRV-B-9 infrared radiant heater stands out for its innovative technology, impressive output, energy efficiency, and safety features. Its flexibility and robust design make it an ideal choice for businesses looking to enhance comfort while minimizing energy costs. Whether in a manufacturing plant or a retail outlet, the CRV-B-9 provides a reliable and effective heating solution.