Roberts Gorden CRV-B-12A, CRV-B-8, CRV-B-9, CRV-B-6, CRV-B-10, CRV-B-2, CRV-B-4 Protective Grille

Page 18

CRV-SERIES INSTALLATION, OPERATION AND SERVICE MANUAL

Control Packages and Accessories

10001501

Water Resistant Sensor

02770002

System Control

URVCCM

ROBERTS GORDON® ULTRAVAC™ Central Controller

 

(with Modem Chip & Software) Includes:

URVSC

ROBERTS GORDON® ULTRAVAC™ Controller

10080142

Modem Chip

10081501

Outdoor Sensor

10080410

PC Connection Cable Package

URVCCR

ROBERTS GORDON® ULTRAVAC™ Central Controller

 

(with RS-485 Converter & Software) Includes:

URVSC

ROBERTS GORDON® ULTRAVAC™ Controller

10080430

RS-485 Converter with 9 V Power Supply

10081501

Outdoor Sensor

10080410

PC Connection Cable Package

URVCCL

ROBERTS GORDON® ULTRAVAC™ Central Controller

 

(with TCP/IP Communication Module & Software)

 

Includes:

 

 

URVSC

ROBERTS GORDON® ULTRAVAC™ Controller

 

 

10080440

TCP/IP Communication Module

10081501

Outdoor Sensor

10080410

PC Connection Cable Package

URVSC

Controller, ROBERTS GORDON® ULTRAVAC™ , 1

 

Pump 3 Zones (Satellite Control)

VFD75115

Variable Frequency Drive Assembly, 75 HP, 115 V Input

VFD75230

Variable Frequency Drive Assembly, 75 HP, 230 V Input

VFD20230

Variable Frequency Drive Assembly, 2 HP, 230 V Input

10080142

Modem, Plug-In Chip

10080410

Cable Package, PC Connection

10080430

RS-485 Converter with 9V Power Supply

10080440

TCP/IP Communication Module

10081500

Sensor, Adjustable Indoor, Deg F, ROBERTS GORDON®

 

ULTRAVAC™ Controller

10081501

Sensor, Outdoor, ULTRAVAC™

10081502

Sensor, Adjustable Indoor, Deg C, ULTRAVAC™

 

Thermostats

05023000

Load Relay Package

90417600

Transformer Relay - SPST (12 A)

90436300

Transformer Relay - DPST (12 A)

90423000

24 V Low Voltage Thermostat (Marked 1-5)

90424300

Thermostat Guard

 

Deco Grille (1' x 8' [.3 m x 2.4 m])

01363003

Bracket

01365901

End Piece

01326801

Reinforcement

01365903

Joint Piece

91406700

1' (.3 m) x 8' (2.4 m) Protective Grille

 

Deco Grille (2' x 4' [.6 m x 1.2 m])

01365900

Shield Frame

01370408

Reflector Side Extension 8" x 48" (20.3 cm x 122 cm)

01370412

Reflector Side Extension 12" x 48" (30.5 cm x 122 cm)

01370416

Reflector Side Extension 16" x 48" (40.6 cm 122 cm)

91407000

Grille, Aluminum 2' x 4' (.6 m x 1.2 m)

Protective Grille

08050001 Protective Grille, 40" (1 m)

08050002 Protective Grille End Cap

Shields

02750303

Barrier Shield

02751801

Universal Shield

027518SS

Universal Shield, Stainless Steel

02751800

Universal Shield with Holes

 

Pump Packages and Accessories

02719105

EP-100 Pump Package

02719100

EP-100 Pump

02724700

Accessory Package

02716305

EP-201 Pump Package

01312001

EP-201 Pump

01317805

Accessory Package

02712034

EP-203 Pump Package

01312002

EP-203 Pump

01317805

Accessory Package

02723014

EP-301 Pump Package 4"

02730101

EP-301 Pump Assembly

02730104

Accessory Package

02723016

EP-301 Pump Package 6"

02730101

EP-301 Pump Assembly

02730106

Accessory Package

02723034

EP-303 Pump Package 4"

02730103

EP-303 Pump Assembly

02730104

Accessory Package

02723036

EP-303 Pump Package 6"

02730103

EP-303 Pump Assembly

02730106

Accessory Package

Pump Accessories

90430600K Pressure Switch

01327001 Condensate Check Valve Assembly

02718851 Drain Cap, 4" (10 cm)

02718852 Drain Cap, 6" (15 cm)

Starters

10050001

Starter, 120 Vac for EP-203, 3 Ø

10050002

Starter, 12 Vdc for EP-201,

10050003

Starter, 120 Vac for EP-201, 1 Ø

10050008

Starter, 120 Vac for EP-301, 1 Ø

10050009

Contactor Package-230 Vac Coil for EP-301, 2 HP

10050010

Starter, 120 Vac for EP-303, 3 Ø

12

Image 18
Contents CoRayVac Page Roberts GORDON, LLC Page Table of Figures Page Heater Safety Manpower RequirementsCorrosive Chemicals Installer ResponsibilityWall Tag National Standards and Applicable CodesMaintain clearances to combustibles at all times for safety Standard Reflector ONE Side ReflectorUniversal SHIELD, Position Foot Deco Grille National Standards and Applicable Codes Coupling Assembly Tube Adapter Major ComponentsWith Lock Aluminum or Stainless Steel Reflector SideVariable Frequency Drive Adjustable Indoor SensorRoberts Gordon Ultravac Roberts GordonStandard Parts List Contents of CRV-Series Burner CartonProtective Grille Design Requirements Assembly Overview HeaterHeater Installation Critical Hanger PlacementTube Installation Coupling and Tube Assembly2 Elbow Installation ± 2 5 cmReflector Installation 1 Reflector Installation with Hole 2 Reflector InstallationScrew Wire Form Reflector Support Strap Burner Installation Burner Combustion Chamber Gasket End VentOptional Heater Accessories Tee InstallationReflector Joint 1 Reflector Joint Installation 2 Reflector Joint Installation 3 Reflector Joint DetailReflector Side Extension .3.1 Bracket Installation 2 Side Reflector InstallationSee Page 5, through Page 5, for positions Barrier Shield2 Frame Shield Installation Decorative Grille Bracket 2 Decorative Grille 3 Joint Piece and Reinforcement4 End Piece and Reflector End Cap Protective Grille Installation 1 Silicone Cap Installation 2 Grille End Cap Installation3 Grille Installation Kg per foot Corayvac Classic Cast-Iron Adapter Pump Installation and Venting 9.1 Pump Installation EP-200 Condensate Valve AssemblyUnited States Requirements Vertical VentingHorizontal Venting Canadian RequirementsVertical Venting Configuration EP-100 Horizontal Venting Configurations Horizontal Venting 4 10 cm PipeEP-200 Series Horizontal Venting Configurations EP-300 Series Horizontal Venting Configurations Pressurized Outside AIR SupplyNon-Pressurized Duct Design RulesOutside Air Blower Internal Wiring Outside Air Blower Internal Wiring DiagramAir Supply Blower Support Non-Pressurized Outside Air Supply GAS Piping Gas Connection with Flexible Gas HoseRoberts Gordon Ultravactm Control MethodsRoberts Gordon System Control Dpst Transformer Relay P/N120 120 Two Zone Operation without Control Panel 60 Hz 12 Vdc 120 Ground 208 230 Burner Internal Wiring Checking the Gas Line Setting the VacuumStarting the System Checking the Electrical SystemVacuum Reading Sequence of Operation Operation and MaintenancePre-Season Maintenance and Annual Inspection To Shut Off HeaterVehicles and Other Objects Maintenance ChecklistInstallation Code and Annual Inspections ReflectorWindow TubesGas Line Blower Scroll, WheelWith the Power off PumpChart StartTroubleshooting Flow Yes Follow burner check Procedure given aboveReplacement Parts DescriptionPipe Connection General SpecificationsDimensions GAS Inlet PressureEP-203 Pump Specifications Model EP-100Air Supply Blower Specifications EP-303Page Warranty is Void if ROBERTS-GORDON will not PAY forLimitations on Authority Representatives Page Owner Warranty Registration Card Page Page F r a r e d H e a t i n g
Related manuals
Manual 40 pages 12.87 Kb Manual 40 pages 29.7 Kb

CRV-B-4, CRV-B-12, CRV-B-2, CRV-B-10, CRV-B-6 specifications

The Roberts Gordon CRV-B-9 is a state-of-the-art infrared radiant heater designed for industrial and commercial heating applications. Renowned for its efficiency and effectiveness, the CRV-B-9 represents a significant advancement in the world of space heating solutions.

One of the main features of the CRV-B-9 is its advanced infrared technology, which allows for precise heating without the necessity of warming the entire space. This targeted heating provides immediate comfort, as it directly warms objects and people rather than the air around them, making it particularly effective in large warehouses, manufacturing facilities, and retail spaces.

The heater boasts an impressive output of up to 80,000 BTUs, making it suitable for a wide range of applications. It utilizes natural gas as fuel, which contributes to its efficiency and cost-effectiveness. With a robust design and durable construction, the CRV-B-9 is built to withstand the rigors of industrial environments while ensuring a long product lifespan.

Another significant characteristic of the CRV-B-9 is its ability to integrate with advanced control systems. This includes compatibility with programmable thermostats and energy management systems, allowing for optimized temperature control and reduced energy consumption. The heater can be adjusted to suit different operational needs, making it a flexible solution for various heating scenarios.

The CRV-B-9 also features a compact design, allowing for easy installation in a variety of spaces. Its low-profile shape and modular capability enable users to arrange multiple units to achieve the desired heating coverage without compromising floor space, a crucial aspect for busy, high-traffic areas.

Safety is a priority with the CRV-B-9, which is equipped with various safety features such as a flame safety cutoff switch and over-temperature protection. These mechanisms ensure safe operation, providing peace of mind for users in demanding environments.

In summary, the Roberts Gordon CRV-B-9 infrared radiant heater stands out for its innovative technology, impressive output, energy efficiency, and safety features. Its flexibility and robust design make it an ideal choice for businesses looking to enhance comfort while minimizing energy costs. Whether in a manufacturing plant or a retail outlet, the CRV-B-9 provides a reliable and effective heating solution.