Roberts Gorden CRV-B-6, CRV-B-8, CRV-B-9 ROBERTS-GORDON will not PAY for, Warranty is Void if

Page 67

SECTION 18: THE ROBERTS GORDON® CORAYVAC® LIMITED WARRANTY

SECTION 18: THE ROBERTS GORDON® CORAYVAC® LIMITED WARRANTY

ROBERTS-GORDON WILL PAY FOR:

Within 42 months from date of shipment from Roberts- Gordon, replacement parts will be provided free of charge for any part of the product which fails due to a manufacturing or material defect.

Roberts-Gordon will require the part in question to be returned to the factory. Roberts-Gordon will, at its sole discretion, repair or replace after determining the nature of the defect and disposition of part in question.

ROBERTS GORDON® warrants the cast iron combustion chamber of the CORAYVAC® Classic System will be free from defects in material and workmanship. This warranty is limited to twenty-five

(25)years from the date of shipment by Roberts- Gordon. All other components of the CORAYVAC® Classic System adhere to the standard warranty listed in the paragraph above.

ROBERTS GORDON® Replacement Parts are warranted for a period of 18 months from date of shipment from Roberts-Gordon or the remaining CORAYVAC® warranty.

ROBERTS-GORDON WILL NOT PAY FOR:

Service trips, service calls and labor charges. Shipment of replacement parts.

Claims where the total price of the goods have not been paid.

Damage due to:

Improper installation, operation or maintenance.

Misuse, abuse, neglect, or modification of the CORAYVAC® in any way.

Use of the CORAYVAC® for other than its intended purpose.

Incorrect gas or electrical supply, accident, fire, floods, acts of God, war, terrorism, or other casualty.

Improper service, use of replacement parts or accessories not specified by Roberts-Gordon.

Failure to install or maintain the CORAYVAC® as directed in the Installation, Operation and Service Manual.

Relocation of the CORAYVAC® after initial installation

The use of the CORAYVAC® in a corrosive atmosphere containing contaminants.

The use of the CORAYVAC® in the vicinity of a combustible or explosive material.

Any defect in the CORAYVAC® arising from a drawing, design, or specification supplied by or on behalf of the consumer.

Damage incurred during shipment. Claim must be filed with carrier.

WARRANTY IS VOID IF:

The CORAYVAC® is not installed by a contractor qualified in the installation and service of gas fired heating equipment.

You cannot prove original purchase date and required annual maintenance history.

The data plate and/or serial number are removed, defaced, modified or altered in any way.

The ownership of the CORAYVAC® is moved or transferred. This warranty is nontransferable.

Roberts-Gordon is not permitted to inspect the damaged controller and/or component parts.

READ YOUR INSTALLATION, OPERATION AND SERVICE MANUAL

If you have questions about your controller, contact your installing professional. Should you need Replacement Parts or have additional questions, call or write Roberts- Gordon:

U.S.A.

1250 William Street P.O. Box 44

Buffalo, New York 14240-0044 716.852.4400

On the web at: www.rg-inc.com

Roberts-Gordon's liability, and your exclusive remedy, under this warranty or any implied warranty (including the implied warranties of merchantability and fitness for a particular purpose) is limited to providing replacement parts during the term of this warranty.

Some jurisdictions do not allow limitations on how long an implied warranty lasts, so this limitation may not apply to you. There are no rights, warranties or conditions, expressed or implied, statutory or otherwise, other than those contained in this warranty.

Roberts-Gordon shall in no event be responsible for incidental or consequential damages or incur liability for damages in excess of the amount paid by you for the CORAYVAC®. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages, so this limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from jurisdiction to jurisdiction.

Roberts-Gordon shall not be responsible for failure to perform under the terms of this warranty if caused by circumstances out of its control, including but not limited to war, fire, flood, strike, government or court orders, acts of God, terrorism, unavailability of supplies, parts or power. No person is authorized to assume for Roberts-Gordon any other warranty, obligation or liability.

LIMITATIONS ON AUTHORITY OF

REPRESENTATIVES:

No representative of Roberts-Gordon, other than an Executive Officer, has authority to change or extend these provisions. Changes or extensions shall be binding only if confirmed in writing by Roberts-Gordon's duly authorized Executive Officer.

61

Image 67
Contents CoRayVac Page Roberts GORDON, LLC Page Table of Figures Page Manpower Requirements Heater SafetyNational Standards and Applicable Codes Installer ResponsibilityWall Tag Corrosive ChemicalsMaintain clearances to combustibles at all times for safety ONE Side Reflector Standard ReflectorUniversal SHIELD, Position Foot Deco Grille National Standards and Applicable Codes Major Components Coupling Assembly Tube AdapterWith Lock Reflector Side Aluminum or Stainless SteelRoberts Gordon Adjustable Indoor SensorRoberts Gordon Ultravac Variable Frequency DriveContents of CRV-Series Burner Carton Standard Parts ListProtective Grille Design Requirements Heater Assembly OverviewCritical Hanger Placement Heater InstallationCoupling and Tube Assembly Tube Installation± 2 5 cm 2 Elbow Installation2 Reflector Installation Reflector Installation 1 Reflector Installation with HoleScrew Wire Form Reflector Support Strap Burner Combustion Chamber Gasket End Vent Burner InstallationTee Installation Optional Heater AccessoriesReflector Joint 1 Reflector Joint Installation 3 Reflector Joint Detail 2 Reflector Joint Installation2 Side Reflector Installation Reflector Side Extension .3.1 Bracket InstallationBarrier Shield See Page 5, through Page 5, for positions2 Frame Shield Installation Decorative Grille Bracket 3 Joint Piece and Reinforcement 2 Decorative Grille4 End Piece and Reflector End Cap 2 Grille End Cap Installation Protective Grille Installation 1 Silicone Cap Installation3 Grille Installation Kg per foot Corayvac Classic Cast-Iron Adapter EP-200 Condensate Valve Assembly Pump Installation and Venting 9.1 Pump InstallationCanadian Requirements Vertical VentingHorizontal Venting United States RequirementsVertical Venting Configuration Horizontal Venting 4 10 cm Pipe EP-100 Horizontal Venting ConfigurationsEP-200 Series Horizontal Venting Configurations EP-300 Series Horizontal Venting Configurations Duct Design Rules Outside AIR SupplyNon-Pressurized PressurizedOutside Air Blower Internal Wiring Diagram Outside Air Blower Internal WiringAir Supply Blower Support Non-Pressurized Outside Air Supply Gas Connection with Flexible Gas Hose GAS PipingDpst Transformer Relay P/N Control MethodsRoberts Gordon System Control Roberts Gordon Ultravactm120 120 Two Zone Operation without Control Panel 60 Hz 12 Vdc 120 Ground 208 230 Burner Internal Wiring Checking the Electrical System Setting the VacuumStarting the System Checking the Gas LineVacuum Reading To Shut Off Heater Operation and MaintenancePre-Season Maintenance and Annual Inspection Sequence of OperationReflector Maintenance ChecklistInstallation Code and Annual Inspections Vehicles and Other ObjectsBlower Scroll, Wheel TubesGas Line WindowPump With the Power offStart ChartYes Follow burner check Procedure given above Troubleshooting FlowDescription Replacement PartsGAS Inlet Pressure General SpecificationsDimensions Pipe ConnectionEP-303 Pump Specifications Model EP-100Air Supply Blower Specifications EP-203Page ROBERTS-GORDON will not PAY for Warranty is Void ifLimitations on Authority Representatives Page Owner Warranty Registration Card Page Page F r a r e d H e a t i n g
Related manuals
Manual 40 pages 12.87 Kb Manual 40 pages 29.7 Kb

CRV-B-4, CRV-B-12, CRV-B-2, CRV-B-10, CRV-B-6 specifications

The Roberts Gordon CRV-B-9 is a state-of-the-art infrared radiant heater designed for industrial and commercial heating applications. Renowned for its efficiency and effectiveness, the CRV-B-9 represents a significant advancement in the world of space heating solutions.

One of the main features of the CRV-B-9 is its advanced infrared technology, which allows for precise heating without the necessity of warming the entire space. This targeted heating provides immediate comfort, as it directly warms objects and people rather than the air around them, making it particularly effective in large warehouses, manufacturing facilities, and retail spaces.

The heater boasts an impressive output of up to 80,000 BTUs, making it suitable for a wide range of applications. It utilizes natural gas as fuel, which contributes to its efficiency and cost-effectiveness. With a robust design and durable construction, the CRV-B-9 is built to withstand the rigors of industrial environments while ensuring a long product lifespan.

Another significant characteristic of the CRV-B-9 is its ability to integrate with advanced control systems. This includes compatibility with programmable thermostats and energy management systems, allowing for optimized temperature control and reduced energy consumption. The heater can be adjusted to suit different operational needs, making it a flexible solution for various heating scenarios.

The CRV-B-9 also features a compact design, allowing for easy installation in a variety of spaces. Its low-profile shape and modular capability enable users to arrange multiple units to achieve the desired heating coverage without compromising floor space, a crucial aspect for busy, high-traffic areas.

Safety is a priority with the CRV-B-9, which is equipped with various safety features such as a flame safety cutoff switch and over-temperature protection. These mechanisms ensure safe operation, providing peace of mind for users in demanding environments.

In summary, the Roberts Gordon CRV-B-9 infrared radiant heater stands out for its innovative technology, impressive output, energy efficiency, and safety features. Its flexibility and robust design make it an ideal choice for businesses looking to enhance comfort while minimizing energy costs. Whether in a manufacturing plant or a retail outlet, the CRV-B-9 provides a reliable and effective heating solution.