York 122, YLCC 42/62/82/102/112, YLCC-h, 152 manual Controls, Accessories

Page 6

connected and tested.The electric box has a door with a block- ing mechanism and contains the compressor and fan contac- tors, fuses and electrical protection. Also has IP44 protec- tion.

Centrifugal fans

Transmission is by belts and removable core pulleys. The motors are mounted on tensing bases fastened directly to the fan casing.

Two versions are available: with horizontal or vertical air dis- charge

Compatible with the following units:

GH200

for size 42

GH260

for sizes 62 and 82

GH600S

for sizes 102 and 122

GH600P

for size 152

Controls

So as to achieve maximum energy savings, perfect opera- tion of the equipment and prolong the useful life of same, the YLCC water chillers or heat pump units are equipped with the following controls:

- Electronic thermostat that controls cold water return tem- perature.

-Electronic antifreeze thermostat.

-High pressure switch, 31 bar.

-Low pressure switch, 2 bar.

-Stage rotation (included in the thermostat).

-Remote terminal unit (optional).

-Timed start.

-Remote control.

comp

PRG

 

 

mute

 

 

 

clear

 

SEL

chillerµ

 

 

x 100

 

 

Accessories

Hydro kit GH

Includes: Buffer tank, automatic air purger, pressure gauge, automatic 1.5 bar filling valve, expansion vessel, pump, flow switch, drain valve, safety valve and electronic board for in- terconnection. Available in 200, 260 and 600 litre capacities. There are two versions of GH600: GH600S and GH600P.

DI buffer tanks

Cylindrical shape and in vertical position. Available in 200, 260 and 600 litre capacities.

Low ambient kit (factory-mounted, optional)

This accessory allows operation of the unit when the con- densing outdoor air temperature is below 10° C.

General information

This accessory controls condensing pressure in the winter cycle by varying air flow through the outdoor coils. This flow variation keeps condensing pressure constant when outdoor temperatures are low.

Operation

By means of the pressure detected through the analogical pressure switches installed in the cooling circuit, and carry- ing out the appropriate calculations as programmed, this con- trol generates an analogical signal that opens the dampers to maintain the condensing pressure previously programmed as the set point.

6

Image 6
Contents Technical information Page Technical specifications IndexPage General characteristics Mechanical specificationsNomenclature Accessories ControlsAnti-vibratory supports Remote control accessoryFlow switch optional accessory Remote terminalPhysical data and electrical characteristics Cooling onlyHeat pump units YLCC-HLimits of use, YLCC-H heat pump unit Limits of useLimits of use,YLCC cooling only unit Nominal flows, cool onlyCooling capacities YLCC-102 YLCC-H-42 102 Heating capacities LWT CYLCC-H-102 YLCC/YLCC-H 42 YLCC/YLCC-H YLCC/YLCC-H 82YLCC/YLCC-H Fan performances 82/82VCorrecting factors Factors with water and glycolEnvironmental protection General informationInspection TransportationDrainage Location dimensionsClearances Locating and securing the unitHydraulic connections diagram Hydraulic connectionsCirculating pump Flow switchHydro kits GH Application to YLCC/YLCC-H unitsWiring Remote control connection optional YLCC/YLCC-H 42, 62, 82YLCC/YLCC-H 122 Ylcc and YLCC-H control system Standard componentsInterconnecting diagram NTC ProbeRemote control unit Identification of system intakes and outletsSerial board RS485 Fig Programmable key FigCopying the Eeprom memory on the key RS485 serial boardUnit addressing Access to Direct parametersAccess to User parameters Unit controlInstallation of default parameters Access to Factory parametersAlarm reset Adjusting display contrastOperation of cooling cycle Operation of set pointsCompressors Operation of heating cycleDefrost cycle Pump operationCooling cycle compressor on Heating cycle compressor onAlarms and messages ID4 IdcomProbe calibration Buzzer configurationYellow and green LEDs on base plate Remote ON/OFFHeating cycle YLCC-H Summer cycle diagram forYLCC-HWinter cycle diagram forYLCC-H Cooling cycle YLCC-HGeneral dimensions mm Ylcc andYLCC-HYlcc andYLCC-H 82 Ylcc andYLCC-H Minimum Electrical Connection Clearance Ylcc andYLCC-H 122V Wiring diagram, YLCC-H 42 and 62, 400.3.50 1 400V, 3 ~, 50 Hz, NWiring diagram, YLCC-H 42 and 62, 400.3.50 2 Wiring diagram, YLCC-H 82, 400.3.50 1 Reg. a 400V, 3 ~, 50 Hz, NWiring diagram, YLCC-H 82, 400.3.50 2 Wiring diagram, YLCC-H 102, 400.3.50 1 Wiring diagram, YLCC-H 102, 400.3.50 2 Wiring diagram, YLCC-H 122, 400.3.50 1 Wiring Wiring diagram, YLCC-H 152, 400.3.50 1 Diagram, YLCC-H Wiring diagram, YLCC- 42 and 62, 400.3.50 1 Diagram, Ylcc Wiring diagram, YLCC- 82, 400.3.50 1 Diagram,YLCC Wiring diagram, YLCC- 102, 400.3.50 1 Diagram Wiring diagram, YLCC- 122, 400.3.50 1 Diagram Wiring diagram, YLCC- 152, 400.3.50 1 152 Page Ref. Y-R70102