York YHJD18 warranty 47.5 32.6 9X*C20

Page 17

HEATING CAPACITY - With High Efficiency Motor Furnaces (Continued)

MODEL

FURNACE

COIL1

 

 

 

ARI HEATING2

 

 

 

MODEL

MODEL

 

47F

 

 

 

 

17F

 

HSPF

 

 

 

MBH

COP

KW

 

MBH

 

COP

KW

STD

 

T*(8,L)X*C16

FC/PC60C

47.0

3.46

3.98

 

32.8

 

2.28

4.22

8.00

 

T*9X*C16

FC/PC60C

47.0

3.46

3.98

 

32.8

 

2.28

4.22

8.00

 

T*(8,L)X*C20

FC/MC/PC60D

47.0

3.48

3.96

 

32.8

 

2.28

4.22

8.00

 

T*9X*C20

FC/PC60C

47.0

3.48

3.96

 

32.6

 

2.30

4.15

8.00

 

T*9X*D20

FC/MC/PC60D

46.5

3.50

3.89

 

32.2

 

2.32

4.07

8.10

 

T*9X*D20

FC/MC62D

47.5

3.54

3.93

 

32.6

 

2.30

4.15

8.00

 

T*(8,L)X*C16

UC60C

47.5

3.58

3.89

 

32.6

 

2.34

4.08

8.10

 

T*(8,L)X*C20

UC60D

47.0

3.64

3.78

 

32.0

 

2.40

3.91

8.10

 

T*9X*C16

UC60C

47.5

3.58

3.89

 

32.6

 

2.34

4.08

8.00

 

T*9X*C20

UC60C

47.5

3.60

3.87

 

32.6

 

2.34

4.08

8.10

 

T*9X*D20

UC60D

46.5

3.60

3.79

 

32.0

 

2.38

3.94

8.10

 

(Y*9C/T*9V)*D20

FC/MC/PC60D

47.5

3.38

4.12

 

30.4

 

2.38

3.74

8.50

 

(Y*9C/T*9V)*D20

FC/MC62D

48.0

3.44

4.09

 

30.2

 

2.40

3.69

8.50

YHJD48S41S1

Y*(8,L)C*C16

FC/PC60C

47.5

3.40

4.09

 

30.4

 

2.40

3.71

8.50

Y*(8,L)C*C20

FC/PC60C

47.5

3.46

4.02

 

30.2

 

2.42

3.66

8.60

 

 

 

 

(Y*9C/T*9V)*C16

FC/PC60C

48.0

3.38

4.16

 

30.6

 

2.38

3.77

8.50

 

(Y*9C/T*9V)*C20

FC/PC60C

48.0

3.38

4.16

 

30.6

 

2.38

3.77

8.50

 

(Y*9C/T*9V)*D20

HC60

48.0

3.48

4.04

 

30.4

 

2.44

3.65

8.50

 

Y*(8,L)C*C16

HD60

47.0

3.22

4.28

 

30.2

 

2.24

3.95

8.40

 

Y*(8,L)C*C20

HD60

47.0

3.24

4.25

 

30.0

 

2.28

3.86

8.40

 

(Y*9C/T*9V)*C16

HD60

47.5

3.18

4.38

 

30.2

 

2.24

3.95

8.40

 

(Y*9C/T*9V)*C20

HD60

47.5

3.18

4.38

 

30.2

 

2.24

3.95

8.40

 

(Y*9C/T*9V)*D20

HD60

47.5

3.20

4.35

 

30.2

 

2.24

3.95

8.40

 

Y*(8,L)C*C16

UC60C

47.5

3.46

4.02

 

30.2

 

2.42

3.66

8.50

 

Y*(8,L)C*C20

UC60C

47.5

3.52

3.95

 

30.0

 

2.46

3.57

8.60

 

(Y*9C/T*9V)*C16

UC60C

48.0

3.44

4.09

 

30.4

 

2.42

3.68

8.50

 

(Y*9C/T*9V)*C20

UC60C

48.0

3.44

4.09

 

30.4

 

2.42

3.68

8.50

 

(Y*9C/T*9V)*D20

UC60D

48.0

3.44

4.09

 

30.2

 

2.42

3.66

8.50

 

T*(8,L)X*C20

FC/MC62D

56.5

3.60

4.60

 

32.6

 

2.46

3.88

8.10

 

T*9X*D20

FC/MC62D

56.5

3.44

4.81

 

34.0

 

2.34

4.26

8.00

YHJD60S41S1

(Y*9C/T*9V)*D20

FC/MC/PC60D

55.5

3.30

4.93

 

35.0

 

2.40

4.27

8.50

 

Y*(8,L)C*C20

FC/MC62D

55.5

3.42

4.76

 

34.6

 

2.44

4.16

8.60

 

(Y*9C/T*9V)*C20

FC/MC62D

56.0

3.36

4.88

 

35.0

 

2.40

4.27

8.60

1.Rated CFM same as for cooling.

2.Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no supplemental electric heat operation.

3.Variable speed furnaces have B.O.D (Blower on Delay) standard.

CP equals MBH output divided by (total KW input x 3.412).

HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period.

— = Not Applicable.

Johnson Controls Unitary Products

17

Image 17
Contents Listed Model Physical and Electrical DataFootnotes ProceduresCooling Model MODEL1 Rated NET MBH Seer EER CFM Unit AIR HandlerSens Seer HP withYHJD60S41S1 AHX60 Seer HP with AHP / SHP / AHX / F*FPFC/MC/PC18 CFM Total Sens Seer HP with Variable Speed FURNACES2 Unit Model Furnace Coil MODEL1 CoolingUC48C UC48D Seer EER CFM Unit Furnace Coil Cooling Model MODEL1 RatedHspf Unit AIR COIL1 ARI HEATING2 Model HandlerMBH COP STD Seer HP With MA Seer HP with MVSHP / AHX / F*FP MBH COP STD Seer HP with AHPMBH COP STD Unit COIL1 ARI HEATING2 ModelMBH COP STD Seer HP With Variable Speed FURNACES3 Model Furnace COIL1 ARI HEATING2Model MBH COP STD 41.0 27.6 9X*C16 47.5 32.6 9X*C20 Accessories Typical Installation Entering AIR TemperatureCondensing FC/MC/PC24 FC/MC/PC30 FC/MC/PC32 FC/MC/PC35 FC/MC/PC32 FC/MC/PC35 FC/MC/PC37 FC/MC/PC43 FC/MC/PC37 FC/MC/PC43 FC/MC/PC48 On next UC48D FC/MC/PC48 FC/MC/PC60 MA20D MC62D MV20D MBH COP EnteringOutdoor Unit Indoor Coil 600 800 1000 38.5 31.4 1000 1200 1400 AHP/SHP48 AHX42 AHX48 UC48D 57.0 Johnson Controls Unitary Products Johnson Controls Unitary Products York Drive Norman, OK