HEATING PERFORMANCE DATA
CONDENSING UNIT MODEL NO | YHJD18S41S1 |
|
|
|
|
|
|
| ||
EVAPORATOR COIL MODEL NO | AHP18 |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
AIR TEMP. | AIR TEMP. |
|
|
|
| ID CFM |
|
|
|
|
|
|
|
|
|
|
|
|
| ||
ENTERING | ENTERING |
| 450 |
|
| 600 |
|
| 750 |
|
OUTDOOR UNIT | INDOOR COIL |
|
|
|
|
|
|
|
|
|
MBTUH | KW | C.O.P. | MBTUH | KW | C.O.P. | MBTUH | KW | C.O.P. | ||
|
|
|
|
|
|
|
|
|
|
|
| 60 | 19.7 | 1.6 | 3.7 | 21.0 | 1.6 | 3.9 | 22.3 | 1.6 | 4.2 |
60 |
|
|
|
|
|
|
|
|
|
|
70 | 18.3 | 1.6 | 3.3 | 19.6 | 1.6 | 3.5 | 20.9 | 1.6 | 3.8 | |
|
|
|
|
|
|
|
|
|
|
|
| 80 | 16.8 | 1.7 | 2.9 | 18.1 | 1.7 | 3.2 | 19.5 | 1.7 | 3.4 |
|
|
|
|
|
|
|
|
|
|
|
| 60 | 16.4 | 1.5 | 3.3 | 17.6 | 1.5 | 3.5 | 18.8 | 1.5 | 3.7 |
47 |
|
|
|
|
|
|
|
|
|
|
70 | 15.2 | 1.5 | 3.0 | 16.4 | 1.5 | 3.2 | 17.6 | 1.5 | 3.3 | |
|
|
|
|
|
|
|
|
|
|
|
| 80 | 14.0 | 1.5 | 2.7 | 15.2 | 1.6 | 2.8 | 16.4 | 1.6 | 3.0 |
|
|
|
|
|
|
|
|
|
|
|
| 60 | 14.9 | 1.4 | 3.1 | 16.2 | 1.4 | 3.3 | 17.5 | 1.5 | 3.5 |
40 |
|
|
|
|
|
|
|
|
|
|
70 | 12.4 | 1.4 | 2.5 | 14.3 | 1.5 | 2.9 | 16.3 | 1.5 | 3.2 | |
|
|
|
|
|
|
|
|
|
|
|
| 80 | 9.9 | 1.5 | 2.0 | 12.5 | 1.5 | 2.4 | 15.0 | 1.6 | 2.8 |
|
|
|
|
|
|
|
|
|
|
|
| 60 | 10.3 | 1.3 | 2.2 | 11.5 | 1.4 | 2.4 | 12.7 | 1.5 | 2.5 |
30 |
|
|
|
|
|
|
|
|
|
|
70 | 11.5 | 1.3 | 2.5 | 12.7 | 1.4 | 2.7 | 14.0 | 1.4 | 2.9 | |
|
|
|
|
|
|
|
|
|
|
|
| 80 | 12.6 | 1.3 | 2.8 | 13.9 | 1.4 | 3.0 | 15.2 | 1.4 | 3.2 |
|
|
|
|
|
|
|
|
|
|
|
| 60 | 7.6 | 1.2 | 1.9 | 7.8 | 1.3 | 1.8 | 7.9 | 1.4 | 1.7 |
17 |
|
|
|
|
|
|
|
|
|
|
70 | 8.2 | 1.2 | 2.0 | 8.5 | 1.3 | 2.0 | 8.8 | 1.3 | 2.0 | |
|
|
|
|
|
|
|
|
|
|
|
| 80 | 8.8 | 1.2 | 2.2 | 9.2 | 1.2 | 2.2 | 9.7 | 1.3 | 2.2 |
|
|
|
|
|
|
|
|
|
|
|
| 60 | 6.1 | 1.1 | 1.6 | 6.7 | 1.2 | 1.6 | 7.3 | 1.3 | 1.7 |
10 |
|
|
|
|
|
|
|
|
|
|
70 | 6.2 | 1.1 | 1.6 | 7.1 | 1.2 | 1.7 | 8.0 | 1.3 | 1.8 | |
|
|
|
|
|
|
|
|
|
|
|
| 80 | 6.2 | 1.1 | 1.6 | 7.4 | 1.2 | 1.8 | 8.6 | 1.3 | 2.0 |
|
|
|
|
|
|
|
|
|
|
|
NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
Air Handlers | Coils | MBH | KW | COP |
– | FC/MC/PC18 | 1.00 | 1.00 | 1.00 |
– | FC/MC/PC24 | 1.03 | 1.04 | 0.99 |
– | HC18 | 1.00 | 1.00 | 1.00 |
– | HC30 | 1.02 | 1.02 | 0.99 |
– | HD24 | 0.97 | 0.96 | 1.02 |
AHP18 | – | 1.02 | 1.02 | 1.00 |
AV24 | – | 0.98 | 0.99 | 1.00 |
F4FP024 | – | 1.01 | 1.01 | 1.00 |
MV12B | FC/MC/PC18B | 0.98 | 0.98 | 1.00 |
MA08B | FC/MC/PC18B | 1.00 | 1.00 | 1.00 |
MA08B | FC/MC/PC24B | 1.03 | 1.04 | 0.99 |
MV12B | FC/MC/PC24B | 1.00 | 1.02 | 0.99 |
Furnaces | Coils | MBH | KW | COP |
Y*(8,L)C*A12 | FC/MC/PC18A | 0.98 | 1.07 | 0.92 |
Y*(8,L)C*B12 | FC/MC/PC18B | 0.97 | 1.06 | 0.92 |
(Y*9C/T*9V)*B12 | FC/MC/PC18B | 0.98 | 1.07 | 0.92 |
Y*(8,L)C*A12 | FC/MC/PC24A | 1.01 | 1.10 | 0.92 |
Y*(8,L)C*B12 | FC/MC/PC24B | 0.99 | 1.10 | 0.90 |
(Y*9C/T*9V)*B12 | FC/MC/PC24B | 1.01 | 1.11 | 0.91 |
Y*(8,L)C*A12 | FC/MC/PC30A | 1.01 | 1.10 | 0.92 |
Y*(8,L)C*B12 | FC/MC/PC30B | 0.99 | 1.10 | 0.90 |
(Y*9C/T*9V)*B12 | FC/MC/PC30B | 1.01 | 1.11 | 0.91 |
Y*(8,L)C*A12 | HC18 | 0.98 | 1.07 | 0.92 |
Y*(8,L)C*A12 | HC30 | 0.99 | 1.07 | 0.93 |
Y*(8,L)C*A12 | HD24 | 0.98 | 1.06 | 0.93 |
Y*(8,L)C*B12 | HD24 | 0.96 | 1.04 | 0.92 |
(Y*9C/T*9V)*B12 | HD24 | 0.98 | 1.07 | 0.92 |
Y*(8,L)C*A12 | UC18A | 0.99 | 1.08 | 0.92 |
Y*(8,L)C*B12 | UC18B | 0.98 | 1.07 | 0.92 |
(Y*9C/T*9V)*B12 | UC18B | 0.99 | 1.08 | 0.91 |
Y*(8,L)C*A12 | UC24A | 1.02 | 1.11 | 0.91 |
Y*(8,L)C*B12 | UC24B | 0.99 | 1.10 | 0.90 |
(Y*9C/T*9V)*B12 | UC24B | 1.01 | 1.12 | 0.91 |
Y*(8,L)C*A12 | UC30A | 1.01 | 1.11 | 0.91 |
Y*(8,L)C*B12 | UC30B | 0.99 | 1.10 | 0.90 |
(Y*9C/T*9V)*B12 | UC30B | 1.01 | 1.12 | 0.91 |
28 | Johnson Controls Unitary Products |