Toshiba RAV-SP180AT2-UL installation manual Contents

Page 2

Outdoor Unit

Installation Manual

Please read this Installation Manual carefully before installing the Air Conditioner.

This Manual describes the installation method of the outdoor unit.

For installation of the indoor unit, refer to the Installation Manual attached to the indoor unit.

ADOPTION OF NEW REFRIGERANT

This Air Conditioner uses R410A an environmentally friendly refrigerant.

Contents

1 DIMENSION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2 ACCESSORY PARTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 3 SYSTEM REQUIREMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 4 PRECAUTIONS FOR SAFETY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 5 INSTALLATION OF NEW REFRIGERANT AIR CONDITIONER. . . . . . . . . . . . . . . . . . 7 6 REFRIGERANT PIPING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 7 ELECTRICAL CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 8 EVACUATE AND DEHYDRATE THE SYSTEM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 9 FINISHING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 10 TEST RUN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 11 PERIODIC MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 12 UNIT PUMP DOWN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 13 POWER SAVE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

1-EN

– 1 –

Image 2
Contents Installation manual Contents Dimension Ø0.26 holeAccessory Parts System Requirements „ Piping Field suppliedPrecautions for Safety Be sure to ground the equipmentEquipment Damage Hazard New Refrigerant Air Conditioner Installation Installation of NEW Refrigerant AIR Conditioner„ Required Tools/Equipment and Precautions for Use Example „ Installation LocationDo not install the outdoor unit in the following location Barrier at rear side Barrier in front „Required ClearancesUnit in mm Upper side is free Above unit is freeBarriers in front and back of unit „ Installation of Outdoor UnitStandard installation Installation Manual „ For ReferenceFlaring Refrigerant Piping„ Tightening of Flare Connections Projection margin in flaring B Unit in mm Rigid Clutch typeDo not apply refrigerant oil to the flared surface Electrical Connections „ Field wiring„ Wiring Deep Vacuum Method Using Vacuum PumpEvacuate and Dehydrate the System Triple Evacuation MethodFinal Tubing Check Open service valvesValve handling precautions Liquid and gas side10TEST RUN 11PERIODIC MaintenanceFinishing 12UNIT Pump Down 13POWER SaveProcedure EH99865301

RAV-SP180AT2-UL specifications

The Toshiba RAV-SP180AT2-UL is an innovative ducted air conditioning unit designed to deliver exceptional cooling and heating capabilities for both residential and commercial applications. Known for its efficiency and performance, this model integrates advanced technology that ensures optimal indoor climate control.

One of the primary features of the RAV-SP180AT2-UL is its energy efficiency. It operates with a high Energy Efficiency Ratio (EER) and Seasonal Energy Efficiency Ratio (SEER) ratings, allowing it to consume less electricity while providing maximum comfort. This efficiency not only contributes to lowering energy bills but also promotes environmentally friendly practices by reducing carbon emissions.

The air conditioning unit is equipped with Toshiba’s advanced inverter technology. This technology allows for precise temperature control and significant energy savings by continuously adjusting the compressor speed based on the desired temperature. With this capability, the system can operate quietly and maintain a stable climate, avoiding the sharp temperature fluctuations characteristic of traditional fixed-speed units.

Another significant feature of the RAV-SP180AT2-UL is its compact design, making it suitable for installation in various settings, including small apartments and larger commercial spaces. Its ducted system enables seamless air distribution, reducing visible components and maintaining the aesthetic of the interior space.

The unit also incorporates innovative filtration systems that improve indoor air quality. With advanced air purifying filters, it effectively minimizes allergens, dust, and pollutants, ensuring that the air circulated in the space is clean and healthy.

In terms of control, the RAV-SP180AT2-UL is compatible with a range of smart control options. Users can manage settings remotely via applications or programmable timers, allowing for convenience and the possibility of scheduling cooling and heating cycles according to personal routines.

Overall, the Toshiba RAV-SP180AT2-UL combines efficiency, compact design, and advanced technology, making it a strong contender in the ducted air conditioning market. Its ability to provide comfortable air conditioning solutions while being mindful of energy consumption is a testament to Toshiba's commitment to innovation in climate control technology.