Toshiba RAV-SP180AT2-UL installation manual Dimension, Ø0.26 hole

Page 3

Outdoor Unit

Installation Manual

1 DIMENSION

23.6"(600)3.5"(90)

A legs

Drain hole (2-Ø0.7"(20) × 3.5"(88) long hole)

2.4"(60)

1.2"(30)

Drain hole(Ø1"(25)) 4.3"(108) 4.9"(125)

 

Space required for service

2.1"(54)

2-Ø0.4"(11)×0.6"(14) U-shape holes

(For Ø0.3"(8)-0.4"(10) anchor bolt)

 

23.6"(600)

12.6"(320) (Long hole pitch For anchor bolt)

12"(306) Ø0.2"(6) hole pitch

11.4"(290)

 

1.2"(30)

B legs

0.6"(16)

2-Ø0.4"(11)-0.6"(14)

 

 

 

U-shape hole

 

 

Air intake

(For Ø0.3"(8)-0.4"(10)

 

 

5.9"(150)

12.6"(320)

 

or more

anchor bolts)

 

11.8"(300)

5.9"(150)

or more

 

 

 

or more

(Minimum

 

 

 

 

distance up to wall)

 

 

 

8-Ø0.2"(6) hole

 

19.7"(500)

Air discharge 2-Ø0.4"(11)×0.6"(14) long hole

(For fixing outdoor unit)

or more

 

 

 

(For Ø0.3"(8)-0.4"(10) anchor bol

2-Ø0.4"(11)×0.6"(14) long hole

 

(For Ø0.3"(8)-0.4"(10) anchor bolts)

 

0.2"(5)

19.1"(486)

4.3"(108)

10"(255)

6.2"(157)

3.1"(79)

 

19.1"(486)

17.7"(449)

 

 

 

 

1.3"(33)

2"(51)

Discharge guard

 

 

 

 

1.3"(32)

19.7"(500)

 

 

 

 

12.6"(320)

30.7"(780)

2.1"(54)

 

23.6"(600)

Ø0.4"(11)×0.6"(14)

 

 

 

 

U-shape hole

1.5"(38)

 

 

R0.6"(15)

 

Product

 

 

 

external line

0.4"(11)

2-Ø0.2"(6) hole

 

2-Ø0.2"(6) hole

12.6"(320)

U-shape hole

1.5"(38)

R0.6"(15)

2.1"(54)

 

 

 

Product

 

 

 

external line

 

23.6"(600)

 

Ø0.4"(11)×0.6"(14)

 

 

 

 

0.8"(21)

 

 

 

5.7"(145)

 

0.9"(22)

 

6.1"(155)

 

 

Refrigerant pipe

 

1"(26)

 

 

 

connecting port

 

Charge port

 

(Ø0.3"(6.4) flare at liquid side)

 

 

 

 

5.6"(141)

13.5"(342)

2"(53)

2.7"(69)

3.5"(88)

Refrigerant pipe

 

 

 

connecting port

 

 

 

(Ø0.5"(12.7) flare at gas side)

Discharge guide mounting hole (4-Ø1.8"(4.5) embossing)

Details of A legs

Details of B legs

EN

– 2 –

2-EN

Image 3
Contents Installation manual Contents Ø0.26 hole DimensionAccessory Parts „ Piping Field supplied System RequirementsBe sure to ground the equipment Precautions for SafetyEquipment Damage Hazard Installation of NEW Refrigerant AIR Conditioner „ Required Tools/Equipment and Precautions for UseNew Refrigerant Air Conditioner Installation „ Installation Location Do not install the outdoor unit in the following locationExample Upper side is free Above unit is free „Required ClearancesUnit in mm Barrier at rear side Barrier in front„ Installation of Outdoor Unit Standard installationBarriers in front and back of unit „ For Reference Installation ManualProjection margin in flaring B Unit in mm Rigid Clutch type Refrigerant Piping„ Tightening of Flare Connections FlaringDo not apply refrigerant oil to the flared surface „ Field wiring „ WiringElectrical Connections Triple Evacuation Method Using Vacuum PumpEvacuate and Dehydrate the System Deep Vacuum MethodLiquid and gas side Open service valvesValve handling precautions Final Tubing Check11PERIODIC Maintenance Finishing10TEST RUN 13POWER Save Procedure12UNIT Pump Down EH99865301

RAV-SP180AT2-UL specifications

The Toshiba RAV-SP180AT2-UL is an innovative ducted air conditioning unit designed to deliver exceptional cooling and heating capabilities for both residential and commercial applications. Known for its efficiency and performance, this model integrates advanced technology that ensures optimal indoor climate control.

One of the primary features of the RAV-SP180AT2-UL is its energy efficiency. It operates with a high Energy Efficiency Ratio (EER) and Seasonal Energy Efficiency Ratio (SEER) ratings, allowing it to consume less electricity while providing maximum comfort. This efficiency not only contributes to lowering energy bills but also promotes environmentally friendly practices by reducing carbon emissions.

The air conditioning unit is equipped with Toshiba’s advanced inverter technology. This technology allows for precise temperature control and significant energy savings by continuously adjusting the compressor speed based on the desired temperature. With this capability, the system can operate quietly and maintain a stable climate, avoiding the sharp temperature fluctuations characteristic of traditional fixed-speed units.

Another significant feature of the RAV-SP180AT2-UL is its compact design, making it suitable for installation in various settings, including small apartments and larger commercial spaces. Its ducted system enables seamless air distribution, reducing visible components and maintaining the aesthetic of the interior space.

The unit also incorporates innovative filtration systems that improve indoor air quality. With advanced air purifying filters, it effectively minimizes allergens, dust, and pollutants, ensuring that the air circulated in the space is clean and healthy.

In terms of control, the RAV-SP180AT2-UL is compatible with a range of smart control options. Users can manage settings remotely via applications or programmable timers, allowing for convenience and the possibility of scheduling cooling and heating cycles according to personal routines.

Overall, the Toshiba RAV-SP180AT2-UL combines efficiency, compact design, and advanced technology, making it a strong contender in the ducted air conditioning market. Its ability to provide comfortable air conditioning solutions while being mindful of energy consumption is a testament to Toshiba's commitment to innovation in climate control technology.