Toshiba RAV-SP180AT2-UL Precautions for Safety, Be sure to ground the equipment

Page 6

Outdoor Unit

Installation Manual

4 PRECAUTIONS FOR SAFETY

Installing, starting up, and servicing air--conditioning equipment can be hazardous due to system pressures, electrical components, and equipment location (roofs, elevated structures, etc.).

Only trained, qualified installers and service mechanics should install, start--up, and service this equipment. Untrained personnel can perform basic maintenance functions such as cleaning coils. All other operations should be performed by trained service personnel.

When working on the equipment, observe precautions in the literature and on tags, stickers, and labels attached to the equipment.

Follow all safety codes. Wear safety glasses and work gloves. Keep quenching cloth and fire extinguisher nearby when brazing. Use care in handling, rigging, and setting bulky equipment.

Read these instructions thoroughly and follow all warnings or cautions included in literature and attached to the unit. Consult local building codes and National Electrical Code (NEC) for special requirements. Recognize safety information. This is the safety--alert symbol . When you see this symbol on the unit and in instructions or manuals, be alert to the potential for personal injury.Understand these signal words: DANGER, WARNING, and CAUTION. These words are used with the safety--alert symbol.

DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies hazards which could result in personal injury or death. CAUTION is used to identify unsafe practices which may result in minor personal injury or product and property damage. NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation.

WARNING

Ask an authorized dealer or qualified installation professional to install/maintain the air conditioner. Perform installation work properly according to the Installation Manual.

Inappropriate installation may result in water leakage, electric shock or fire.

Be sure to ground the equipment

Improper grounding may cause an electric shock.

Do not connect ground wires to gas pipes, water pipes, lightning rods or ground wires for telephone wires.

Turn off the circuit breaker before attempting any electrical work and maintenance. Make sure the circuit breaker is off. Failure to do so may cause electric shock.

Use an exclusive power circuit for the air conditioner. Use the rated voltage.

When moving the air conditioner for installation to another place, be very careful not to allow the specified refrigerant (R410A) to become mixed with any other gaseous body into the refrigeration cycle.

If air or any other gas mixes with the refrigerant, the gas pressure in the refrigeration cycle will become abnormally high and it may result in the pipe bursting or personal injuries.

Do not modify this unit by removing any of the safety guards or by by-passing any of the safety interlock switches.

Do not touch the intake or aluminium fins of the outdoor unit. Doing so may result in injury.

Tighten the flare nut with a torque wrench in the specified manner.

Excessive tightening of the flare nut may cause a crack in the flare nut after a long period, which may result in refrigerant leakage.

Install the air conditioner securely in a location where the base can sustain the weight of the unit adequately.

If refrigerant gas has leaked during the installation work, ventilate the room immediately. If the leaked refrigerant gas comes in contact with fire, noxious gas may be generated.

After the installation work, confirm that refrigerant gas does not leak.

If refrigerant gas leaks into the room and flows near a fire source, such as a cooking range, noxious gas may be generated.

Electrical work must be performed by a qualified electrician in accordance with the NEC and local code. Make sure the air conditioner uses an exclusive power supply.

An insufficient power supply capacity or inappropriate installation may cause fire.

Use only the specified wiring during the unit installation. Ensure that all terminals are securely fixed, so preventing any external forces having a negative effect on the terminals.

5-EN

– 5 –

Image 6
Contents Installation manual Contents Dimension Ø0.26 holeAccessory Parts System Requirements „ Piping Field suppliedPrecautions for Safety Be sure to ground the equipmentEquipment Damage Hazard Installation of NEW Refrigerant AIR Conditioner „ Required Tools/Equipment and Precautions for UseNew Refrigerant Air Conditioner Installation „ Installation Location Do not install the outdoor unit in the following locationExample Barrier at rear side Barrier in front „Required ClearancesUnit in mm Upper side is free Above unit is free„ Installation of Outdoor Unit Standard installationBarriers in front and back of unit Installation Manual „ For ReferenceFlaring Refrigerant Piping„ Tightening of Flare Connections Projection margin in flaring B Unit in mm Rigid Clutch typeDo not apply refrigerant oil to the flared surface „ Field wiring „ WiringElectrical Connections Deep Vacuum Method Using Vacuum PumpEvacuate and Dehydrate the System Triple Evacuation MethodFinal Tubing Check Open service valvesValve handling precautions Liquid and gas side11PERIODIC Maintenance Finishing10TEST RUN 13POWER Save Procedure12UNIT Pump Down EH99865301

RAV-SP180AT2-UL specifications

The Toshiba RAV-SP180AT2-UL is an innovative ducted air conditioning unit designed to deliver exceptional cooling and heating capabilities for both residential and commercial applications. Known for its efficiency and performance, this model integrates advanced technology that ensures optimal indoor climate control.

One of the primary features of the RAV-SP180AT2-UL is its energy efficiency. It operates with a high Energy Efficiency Ratio (EER) and Seasonal Energy Efficiency Ratio (SEER) ratings, allowing it to consume less electricity while providing maximum comfort. This efficiency not only contributes to lowering energy bills but also promotes environmentally friendly practices by reducing carbon emissions.

The air conditioning unit is equipped with Toshiba’s advanced inverter technology. This technology allows for precise temperature control and significant energy savings by continuously adjusting the compressor speed based on the desired temperature. With this capability, the system can operate quietly and maintain a stable climate, avoiding the sharp temperature fluctuations characteristic of traditional fixed-speed units.

Another significant feature of the RAV-SP180AT2-UL is its compact design, making it suitable for installation in various settings, including small apartments and larger commercial spaces. Its ducted system enables seamless air distribution, reducing visible components and maintaining the aesthetic of the interior space.

The unit also incorporates innovative filtration systems that improve indoor air quality. With advanced air purifying filters, it effectively minimizes allergens, dust, and pollutants, ensuring that the air circulated in the space is clean and healthy.

In terms of control, the RAV-SP180AT2-UL is compatible with a range of smart control options. Users can manage settings remotely via applications or programmable timers, allowing for convenience and the possibility of scheduling cooling and heating cycles according to personal routines.

Overall, the Toshiba RAV-SP180AT2-UL combines efficiency, compact design, and advanced technology, making it a strong contender in the ducted air conditioning market. Its ability to provide comfortable air conditioning solutions while being mindful of energy consumption is a testament to Toshiba's commitment to innovation in climate control technology.