York SHP48 THRU 60, AHP18 THRU 60 specifications Dimensions, Coil Technical Data

Page 2

255029-YTG-J-1007

DIMENSIONS

 

J

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10-3/8”

 

 

F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K

 

 

 

 

 

 

 

 

 

 

 

 

BLOWER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COMPARTMENT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TOP OUTLET

 

 

 

 

 

 

 

 

A

CIRCUIT BREAKER

 

DIMENSIONS

 

 

 

 

 

 

 

 

 

PANEL

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

REFRIGERANT

DRAIN CONNECTIONS

 

 

 

 

 

 

 

 

 

 

 

FOR UPFLOW AND

 

 

 

 

 

 

 

 

 

 

 

CONNECTIONS

 

 

 

 

 

 

 

 

 

 

 

DOWNFLOW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

APPLICATIONS

 

 

 

 

 

 

 

 

 

 

 

 

7-11/32”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18-9/32”

E

 

 

 

 

 

1-1/2”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

 

BOTTOM INLET

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FILTER

 

 

 

 

 

 

 

 

DIMENSIONS

 

 

ACCESS

DRAIN PAN CONNECTIONS

 

 

 

 

 

 

 

 

 

 

FOR HORIZONTAL APPLICATIONS

 

 

 

 

 

 

DIMENSIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dimensions

 

 

 

Wiring Knockouts1

 

Refrigerant

Models

A

B

C

 

 

 

 

 

J

 

K

 

Connections

 

D

 

E

F

 

 

Line Size

 

Height

Width

Depth

 

 

Power

 

Control

 

Liquid

Vapor

 

 

 

 

 

 

 

 

AHP18B**(N,H)21

46

17.5

 

12-3/8 13-29/32

14-19/32

 

 

 

 

 

3/4”

AHP24B**(N,H)21

46

17.5

 

12-3/8 13-29/32

14-19/32

 

 

 

 

 

3/4”

AHP30B**(N,H)21

46

17.5

 

12-3/8 13-29/32

14-19/32

 

 

 

 

 

3/4”

AHP36C**(N,H)21

52

21

21.5

17-1/8 17-13/32

18-3/32

7/8” (1/2”)

 

 

 

 

7/8”

AHP42C**(N,H)21

52

21

17-1/8

17-13/32

18-3/32

1 3/8” (1”)

 

7/8” (1/2”)

3/8”

7/8”

AHP48D**(N,H)21

57

24.5

 

22-1/8 20-29/32

21-19/32 1 23/32” (1 1/4”)

 

 

 

7/8”

SHP48D**N21

52

24.5

 

17-1/8 20-29/32

21-19/32

 

 

 

 

 

7/8

AHP60D**(N,H)21

57

24.5

 

22-1/8 20-29/32

21-19/32

 

 

 

 

 

7/8’

SHP60D**N21

52

24.5

 

17-1/8

20-29/32

21-19/32

 

 

 

 

 

7/8

1. Actual size (Conduit size).

 

 

 

 

 

 

 

 

 

 

 

 

 

COIL TECHNICAL DATA

 

 

 

 

 

 

 

 

 

 

 

 

 

Models

Application

Refrig.

Face Area

Rows

Fin

Coil Size

Tube

 

Tube

 

Fin

TXV

Conn. Types (Sq. Ft.)

Deep

Per In.

Geometry

 

Dia.

 

Type

AHP18B3X(N,H)21

 

 

3.40

 

 

2

14

(2) 14 x 17.5

 

 

 

 

 

None

AHP18B2A(N,H)21

 

 

3.40

 

 

2

14

 

 

 

 

 

2A

 

 

 

 

 

 

 

 

 

 

AHP24B3X(N,H)21

 

 

3.89

 

 

2

14

(2) 16 x 17.5

 

 

 

 

 

None

AHP24B2A(N,H)21

 

 

3.89

 

 

2

14

 

 

 

 

 

2A

 

 

 

 

 

 

 

 

 

 

AHP30B3X(N,H)21

 

 

3.89

 

 

3

12

(2) 16 x 17.5

 

 

 

 

 

None

AHP30B2A(N,H)21

 

 

3.89

 

 

3

12

 

 

 

 

 

2A

 

 

 

 

 

 

 

 

 

 

AHP36C3X(N,H)21

 

 

4.86

 

 

3

12

(2) 20 x 17.5

 

 

 

 

 

None

AHP36C2A(N,H)21

 

 

4.86

 

 

3

12

 

 

 

 

 

2A

 

 

 

 

 

 

 

 

 

 

AHP42C3X(N,H)21

Cooling /

Sweat

4.86

 

 

3

12

(2) 20 x 17.5

1 x 0.866

 

3/8

Enhanced

None

AHP42C2C(N,H)21

Heat Pump

4.86

 

 

3

12

 

2C

 

 

 

 

 

 

 

 

 

AHP48D3X(N,H)21

 

 

5.83

 

 

3

11

(2) 24 x 17.5

 

 

 

 

 

None

AHP48D2C(N,H)21

 

 

5.83

 

 

3

11

 

 

 

 

 

2C

 

 

 

 

 

 

 

 

 

 

SHP48D3XN21

 

 

5.83

 

 

3

11

(2) 24 x 17.5

 

 

 

 

 

None

SHP48D2CN21

 

 

5.83

 

 

3

11

 

 

 

 

 

2C

 

 

 

 

 

 

 

 

 

 

AHP60D3X(N,H)21

 

 

5.83

 

 

3

11

(2) 24 x 17.5

 

 

 

 

 

None

AHP60D2C(N,H)21

 

 

5.83

 

 

3

11

 

 

 

 

 

2C

 

 

 

 

 

 

 

 

 

 

SHP60D3XN21

 

 

5.83

 

 

3

11

(2) 24 x 17.5

 

 

 

 

 

None

SHP60D2CN21

 

 

5.83

 

 

3

11

 

 

 

 

 

2C

 

 

 

 

 

 

 

 

 

 

Note: H models are available with a factory installed horizontal drain pan.

2

Unitary Products Group

Image 2
Contents Description FeaturesModels AHP18 Thru 60 and SHP48 Thru Coil Technical Data DimensionsDimensions Dry / Wet Bulb Cooling CapacityModels Rated CFM Entering Air F AIR Flow Data 60 Hz Models AccessoriesLimitations Air Handler Voltage 1Normal OperatingApplication Factors Rated CFM VS. Actual CFM Rated AirflowPhysical & Electrical Data Electrical Data Cooling only 60 HzHeater Max Min Total Heat1 KW Staging Models Speed KW & MBH Conversions for Total Power Input RequirementElectrical Data 208/230-1-60 W1 Only W2 Only W1 + W275C Wire Size AWG Min. Circuit AmpacityHeat Kit Max Min Total Heat1 KW Staging Models Speed Electrical Data 208/230-3-601st 2nd 3rd 208/240 W1 OnlyAHP24B**N,H21 4HK06501025 23.1 SINGLE-STAGE Cooling Wiring Cooling Models with Electric Heat WiringCooling Models with Electric Heat Wiring Typical Applications Unitary 5005 Norman Products York Group Drive 73069