York R-410A manual Control Options

Page 7

246824-YTG-G-1208

Motorized Outdoor Air Damper - The motorized outdoor air damper includes a slide-in/plug-in damper assembly with an outdoor air hood and filters. The outdoor air dampers open to the preset position when the indoor fan motor is energized. The damper has a range of 0% to 100% outdoor air entry. Factory installed option or field installed accessory.

Alternate Indoor Blower Motor - For applications with high static restrictions, units are offered with optional indoor motors that provide higher static output and/or higher airflow, depending upon the installer’s needs.

Aluminized Steel Gas Heat Exchanger - For applications in non-corrosive environments.

Stainless Steel Gas Heat Exchanger - For applications in corrosive environments, this option provides a full stainless steel heat exchanger assembly.

Stainless Steel Drain Pan - An optional rust-proof stainless steel drain pan is available to provide years of trouble-free operation in corrosive environments.

Electric Heaters - The electric heaters range from 9kW to 54kW and are available in all the voltage options of the base units. All heaters are dual staged. All heaters are intended for single point power supply.

Disconnect Switch - For gas heat units and cooling units with electric heat, a HACR breaker sized to the unit is provided. For cooling only units, a switch sized to the largest electric heat available for the particular unit is provided. Factory installed option only.

Convenience Outlet - (Non-Powered/Powered) - This option locates a 120V single-phase GFCI outlet with cover, on the corner of the unit housing adjacent to the compressors. The “Non-powered” option requires the installer to provide the 120V single-phase power source and wiring. The “Powered” option is powered by a stepdown transformer in the unit. Factory installed option only.

Smoke Detectors - The smoke detectors stop operation of the unit by interrupting power to the control board if smoke is detected within the air compartment. Available for both the supply and/or return air.

Factory installed smoke detectors in the return air, may be subjected to freezing temperatures during "off" times due to out side air infiltration. These smoke detectors have an operational limit of 32 °F to 131°F. Smoke detectors installed in areas that could be out side those limitations will have to be moved to prevent having false alarms.

Phase Monitors - Designed to prevent unit damage. The phase monitor will shut the unit down in an out-of phase condition. (Standard on units with Scroll Compressors.)

Coil Guard - Customers can purchase a coil guard kit to protect the condenser coil from damage. Additionally, this kit stops animals and foreign objects from entering the space between the inner condenser coil and the main cabinet. This is not a hail guard kit.

Dirty Filter Switch - This kit includes a differential pressure switch that energizes the fault light on the unit thermostat, indicating that there is an abnormally high pressure drop across the filters. Factory installed option or field installed accessory.

Technicoat Condenser Coils - The condenser coils are coated with a phenolic coating for protection against corrosion due to harsh environments.

Technicoat Evaporator Coil - The evaporator coils are coated with a phenolic coating for protection against corrosion due to harsh environments.

Hot Gas Bypass - Allows operation during low load conditions while avoiding coil frosting and damage to compressor. When suction pressure falls below valve setpoint, the valve modulates hot gas to the inlet of the evaporator.

Control Options

BAS - Building Automation System Controls Simplicity® INTELLI-Comfort™ Control - The York® Simplicity® INTELLI-Comfort™ control is factory installed. It includes a supply air sensor, a return air sensor, and an outside air sensor. There are provisions for a field installed dirty filter indicator switch, an air-proving switch, an Outside Air Humidity sensor, a Return Air Humidity sensor, an Inside IAQ sensor, and an Outside Air IAQ sensor. Construction mode operation, 365-day real time clock with 7 day programming plus holiday scheduling is built-in. Two different modes of demand ventilation are achieved through the INTELLI-Comfort™ using CO2 sensors. It uses an inside CO2 sensor to perform Demand Ventilation. It can also use an Outside CO2 sensor to perform Differential Demand Ventilation. It uses a Patented Comfort Ventilation algorithm to provide comfortable ventilation air temperature. The patented economizer-loading algorithm will protect the equipment when harsh operating conditions exist. Humidity in the occupied space or return duct can be monitored and controlled via humidity sensors and the on- board connection for hot gas re-heat system. It uses the INTELLI-Start™ algorithm to maximize energy savings by recovering the building from the Unoccupied Setpoints to the Occupied Setpoints just in time for the Occupied Time Period to begin. The Simplicity® INTELLI-Comfort™ balances space temperature, ventilation air temperature, CO2 and humidity for ultimate comfort.

Simplicity® INTELLI-Comfort™ with ModLINC Control - The York® Simplicity® INTELLI-Comfort™ with ModLINC control is factory installed. It includes all the features of the INTELLI-Comfort™ control with an additional control to translate communications from MODBUS to the BACnet MSTP protocol.

Novar® BAS Control - The Novar® building automation system controller is factory installed. Incudes supply air sensor, return air sensor, dirty filter indicator switch, and air proving switch.

Johnson Controls BAS Control - The Johnson Control YK-UNT-1126 building automation system controller is factory installed. Includes supply air sensor, return air sensor, dirty filter indicator switch, and air proving switch.

Johnson Controls Unitary Products

7

Image 7
Contents Technical Guide Component Location Table of ContentsHeat Pump Nomenclature Ton York Model Number NomenclatureStandard Features Features and BenefitsFactory Installed Options Control Options Field Installed Accessories Part Number Description AccessoriesGeneral Guide SpecificationsIndoor Evaporator FAN Assembly Electric Heating Section if Equipped Reheat Mode Sequence of Operation Reheat Control Board ZH078-150 Physical Data Physical DataFilters ZR078-150 Physical Data Reheat Coil Data XP078-150 Physical Data Min ZH/ZR/XP078-150 Unit LimitationsYTG-G-1208 ZH078-150 Cooling Capacities Capacity PerformanceZH078 6.5 Ton 115F ZH090 7.5 Ton ZH090 7.5 Ton ZH102 8.5 Ton ZH102 8.5 Ton ZH120 10 Ton 115F 125F ZH150 12.5 Ton ZH150 12.5 Ton ZR078 6.5 Ton Cooling ZR078-150 Cooling and Reheat Capacities115F 35F 45F ZR078 6.5 Ton ReheatCapacity Input ZR090 7.5 Ton Cooling 115F ZR090 7.5 Ton Reheat 75F 85F ZR102 8.5 Ton Cooling 115F ZR102 8.5 Ton Reheat 75F 85F ZR120 10 Ton Cooling 115F ZR120 10 Ton Reheat 75F 85F ZR150 12.5 Ton Cooling 115F 125F ZR150 12.5 Ton Reheat 75F 85F XP078 6.5 Ton XP078-150 Cooling Capacities115F 95F 105F XP090 7.5 Ton115F 125F XP102 8.5 Ton 115F XP120 10 Ton XP120 10 Ton XP150 12.5 Ton 115F 125F XP078-150 XP078-150 Heating CapacitiesCapacity Outdoor Temperature F @ 72% RH ZH090 7.5 Ton Side Duct Airflow PerformanceZH078-150 Side Duct Application ZH078 6.5 Ton Side DuctZH150 12.5 Ton Side Duct ZH120 10 Ton Side DuctZH102 8.5 Ton Bottom Duct ZH078-150 Bottom Duct ApplicationZH078 6.5 Ton Bottom Duct ZH090 7.5 Ton Bottom DuctZH150 12.5 Ton Bottom Duct ZH120 10 Ton Bottom DuctZR102 8.5 Ton Side Duct ZR078-150 Side Duct ApplicationZR078 6.5 Ton Side Duct ZR090 7.5 Ton Side DuctZR150 12.5 Ton Side Duct ZR120 10 Ton Side DuctZR102 8.5 Ton Bottom Duct ZR078-150 Bottom Duct ApplicationZR078 6.5 Ton Bottom Duct ZR090 7.5 Ton Bottom DuctZR150 12.5 Ton Bottom Duct ZR120 10 Ton Bottom DuctXP102 8.5 Ton Side Duct XP078-150 Side Duct ApplicationXP078 6.5 Ton Side Duct XP090 7.5 Ton Side DuctXP150 12.5 Ton Side Duct XP120 10 Ton Side DuctXP102 8.5 Ton Bottom Duct XP078-150 Bottom Duct ApplicationXP078 6.5 Ton Bottom Duct XP090 7.5 Ton Bottom DuctXP150 12.5 Ton Bottom Duct XP120 10 Ton Bottom DuctRPM Selection Tons Additional Static ResistanceDrive Selection Airflow PerformanceCorrection Altitude/Temperature Correction FactorsAir Temperature ºF FactorElectric Heat Minimum Supply Air Indoor Blower SpecificationsPower Exhaust Specifications Gas Heat Minimum Supply AirElectric Heat Multipliers Indoor Sound Power LevelsOutdoor Sound Power Levels ZH/ZR/XP078-150 Sound PerformanceElectrical Data ZH078-150 Standard Motor Without Powered Convenience OutletZH078-150 Standard Motor Without Powered Convenience Outlet ZH078-150 Hi Static Motor Without Powered Convenience Outlet ZH078-150 Hi Static Motor Without Powered Convenience Outlet ZH078-150 Standard Motor With Powered Convenience Outlet ZH078-150 Standard Motor With Powered Convenience Outlet ZH078-150 Hi Static Motor With Powered Convenience Outlet ZH078-150 Hi Static Motor With Powered Convenience Outlet ZR078-150 Standard Motor Without Powered Convenience Outlet ZR078-150 Standard Motor Without Powered Convenience Outlet ZR078-150 Hi Static Motor Without Powered Convenience Outlet ZR078-150 Hi Static Motor Without Powered Convenience Outlet ZR078-150 Standard Motor With Powered Convenience Outlet ZR078-150 Standard Motor With Powered Convenience Outlet ZR078-150 Hi Static Motor With Powered Convenience Outlet ZR078-150 Hi Static Motor With Powered Convenience Outlet XP078-150 Standard Motor Without Powered Convenience Outlet XP078-150 Standard Motor Without Powered Convenience Outlet XP078-150 Hi Static Motor Without Powered Convenience Outlet Johnson Controls Unitary Products 101 XP078-150 Standard Motor With Powered Convenience Outlet Johnson Controls Unitary Products 103 XP078-150 Hi Static Motor With Powered Convenience Outlet Johnson Controls Unitary Products 105 ZH/ZR078-150 Typical Wiring Diagrams Typical Wiring DiagramsJohnson Controls Unitary Products 107 108 Johnson Controls Unitary Products Johnson Controls Unitary Products 109 110 Johnson Controls Unitary Products Johnson Controls Unitary Products 111 Typical ZR078-120 Reheat Wiring Diagram Typical ZR150 Reheat Wiring Diagram XP078-150 Typical Wiring Diagrams Johnson Controls Unitary Products 115 ZH/ZR/XP078-150 Unit Weights Weights and DimensionsUnit 4 Point Load Weight Unit 6 Point Load Weight ZH/ZR/XP078-150 Unit Accessory Weights ZH/ZR/XP078-150 Unit DimensionsZH/ZR/XP078-120 ZH/ZR/XP078-150 Unit Bottom Duct Openings ZH/ZR/XP078-150 Unit Physical DimensionsDetail a ZH/ZR/XP078-150 Unit ClearancesZH/ZR/XP078-120 Unit Side Duct Openings ZH/ZR/XP078-150 Unit Electrical EntryZH/ZR/XP150 Unit Side Duct Openings Side Duct DimensionsZH/ZR/XP078-150 Unit Left Duct Opening ZH/ZR/XP078-150 Roof Curb ZH/ZR/XP078-150 Unit Accessory DimensionsZH/ZR/XP078-150 Transition Roof Curb ZH/ZR/XP078-150 Economizer Assembly Economizer Usage Factory Installed Downflow EconomizerField Installed Downflow Economizer W/Power Exhaust Economizer OptionsSlab Economizer Downflow W/Power Exhaust Field Installed Horizontal Economizer W/Power ExhaustSlab Economizer End Return W/Power Exhaust 126 Johnson Controls Unitary Products YTG-G-1208 Johnson Controls Unitary Products 127 Johnson Controls Unitary Products York Drive Norman, OK
Related manuals
Manual 24 pages 22.74 Kb Manual 68 pages 3.65 Kb Manual 104 pages 7.39 Kb Manual 36 pages 24.83 Kb

R-410A specifications

York R-410A is a widely recognized and highly efficient refrigerant used in modern air conditioning systems. Developed as an environmentally friendly alternative to R-22, R-410A has gained popularity in the HVAC industry due to its numerous advantageous features and characteristics.

One of the main features of York R-410A is its ability to provide superior cooling performance. This refrigerant operates efficiently at both high and low temperatures, allowing systems using it to maintain optimal indoor climates even during extreme weather conditions. Its high energy efficiency ratio (EER) and seasonal energy efficiency ratio (SEER) ratings make it a preferred choice for energy-conscious consumers, resulting in lower energy bills and a reduced carbon footprint.

Technologically, York R-410A systems feature advanced compressor designs that enhance their overall reliability and performance. These compressors are often equipped with variable-speed technology, enabling them to adjust their output to match the cooling demands of the space. This not only improves comfort levels but also leads to efficient energy consumption, reducing wear and tear on the equipment over time.

Another significant characteristic of York R-410A is its non-ozone-depleting properties. Unlike its predecessor R-22, which is being phased out due to its damaging effects on the ozone layer, R-410A is designed to minimize environmental impact. Its lower global warming potential (GWP) further underscores its role in promoting sustainability within the HVAC sector.

Furthermore, York R-410A systems are engineered with enhanced safety features. The refrigerant is non-toxic and non-flammable, which makes it safer for use in both residential and commercial applications. Additionally, its high thermal stability reduces the risk of breakdown or leakage, contributing to longer system lifespans and lower maintenance costs.

In conclusion, York R-410A stands out as a cutting-edge refrigerant that combines efficiency, safety, and environmental responsibility. With its advanced technologies and remarkable characteristics, it meets the demands of modern air conditioning requirements while paving the way for a sustainable future in HVAC systems. Adopting York R-410A not only benefits individual users through improved comfort and lower energy bills but also plays a vital role in protecting our planet's ozone layer and mitigating climate change.