Moxa Technologies user manual CP-102U/UL User’s Manual Software Installation

Models: CP-102U/UL

1 78
Download 78 pages 38.36 Kb
Page 33
Image 33

CP-102U/UL User’s Manual

Software Installation

5.Select a COM number for the port from the Port Number pull-down list.

6.Check the Auto Enumerating COM Number checkbox to map subsequent ports automatically. The port numbers will be assigned in sequence. For example, if COM 3 is assigned to Port 1, then COM 4 (if not already occupied) will be assigned to Port 2, etc.

7.Select an Rx FIFO Trigger from the Rx FIFO Level pull-down list. Rx FIFO trigger levels of High, Middle, and Low are available, with the default set to High (120 bytes). Check Set the change to all ports checkbox to apply this Rx FIFO Trigger to all ports.

8.Select a Tx FIFO Level from the Tx FIFO Level pull-down list. Tx FIFO Levels of High, Middle, and Low are available, with the default set to High (128 bytes). Check Set the change to all ports checkbox to apply the just defined Tx FIFO Size to all ports.

 

CP-102U/UL

 

Tx FIFO

Rx FIFO

High

128

120

Middle

64

60

Low

1

1

Unit: Bytes

3-21

Page 33
Image 33
Moxa Technologies user manual CP-102U/UL User’s Manual Software Installation