York R-410A manual Ton York Model Number Nomenclature

Page 4

246824-YTG-G-1208

Nomenclature

6.5-12.5 Ton York® Model Number Nomenclature

Z H 090 N10 A 2 A AA 4 0 1 2 4 A

Product Category

Z= A/C, Single Pkg., R-410A X = HP, Single Pkg., R-410A

Product Identifier

H = 11.0+ EER A/C

P = 11.0 EER HP

R = Reheat

Nominal Cooling Capacity

078 = 6.5 Ton

090 = 7.5 Ton

102 = 8.5 Ton

120 = 10.0 Ton

150 = 12.5 Ton

Heat Type and Nominal Heat Capacity

C00 = Cooling Only. No heat installed

Gas Heat Options

N10 = 100 MBH Output Aluminized Steel

N15 = 150 MBH Output Aluminized Steel

N20 = 200 MBH Output Aluminized Steel

S10 = 100 MBH Output Stainless Steel

S15 = 150 MBH Output Stainless Steel

S20 = 200 MBH Output Stainless Steel

Electric Heat Options

E09 = 9 KW

E18 = 18 KW

E24 = 24 KW

E36 = 36 KW

E54 = 54 KW

Airflow

A = Std. Motor

B = Std. Motor/Econo./Barometric Relief (Downflow

Only)

C = Std. Motor/Econo./Power Exhaust (Downflow Only)

D = Std. Motor/Motorized Damper (Downflow Only)

E = Std. Motor/Horizontal Economizer (No Baro.)

F = Std. Motor/Slab Econo./Power Exhaust

(Downflow Only)

G = Std. Motor/Slab Econo./Barometric Relief

(Downflow Only)

N = Hi Static

P = Hi Static/Econo./Barometric Relief

(Downflow Only)

Q = Hi Static/Econo./Power Exhaust

(Downflow Only)

R = Hi Static/Motorized Damper (Downflow Only)

S = Hi Static/Horizontal Economizer (No Baro.)

T = Hi Static/Slab Econo./Power Exhaust

(Downflow Only)

U = Hi Static/Slab Econo./Barometric Relief

(Downflow only)

Voltage

2 = 208/230-3-60

4 = 460-3-60

5 = 575-3-60

Product Style

A = Style A

B = Style B

C = Style C

Configuration Options (not required for all units)

These four digits will not be assigned until a quote is requested, or an order placed.

SS Drain Pan

CPC Controller, DFS, APS

Johnson Controller UNT 1126 (N2 protocol), DFS, APS

Honeywell Controller, DFS, APS

Novar Controller, DFS, APS

Simplicity IntelliComfort Controller

Simplicity IntelliComfort Controller w/ModLinc

York Commercial Comfort System (YCCS) Rtu Controller

2" Pleated filters

BAS Ready Economizer (2-10 V.D.C. Actuator without a Controller)

Shipping Bag

Any Combination of Additional Options that Don’t Have an Option Code Pre-assigned

Product Generation

4 = Fourth Generation

Additional Options

AA = None

RC = Coil Guard, Shipping Bag & American Flag

AB = Phase Monitor

TA = Technicoat Condenser Coil

AC = Coil Guard

TJ = Technicoat Evaporator Coil

AD = Dirty Filter Switch

TS = Technicoat Evaporator & Condenser Coils

AE = Phase Monitor & Coil Guard

 

AF = Phase Monitor & Dirty Filter Switch

 

AG = Coil Guard & Dirty Filter Switch

 

AH = Phase Monitor, Coil Guard & Dirty Filter Switch

 

 

 

ZZ= If desired option combination is not listed above, ZZ will be assigned and configuration options will be located in digits 15-18.

Installation Options

A = No Options Installed

B = Option 1

C = Option 2

D = Options 1 & 2

E = Option 3

F = Option 4

G = Options 1 & 3

H = Options 1 & 4

J = Options 1, 2 & 3

K = Options 1, 2, & 4

L = Options 1,3 & 4

M = Options 1, 2, 3, & 4

N = Options 2 & 3

P = Options 2 & 4

Q = Options 2, 3, & 4

R = Options 3 & 4

S = Option 5

T = Options 1 & 5

U = Options 1, 3, & 5

V = Options 1, 4, & 5

W = Options 1, 3, 4, & 5

X = Options 3 & 5

Y = Options 4 & 5

Z = Options 3, 4 & 5

Options

1 = Disconnect

2 = Non-Pwr'd Conv. Outlet

3 = Smoke Detector S.A.

4 = Smoke Detector R.A.

5 = Pwr'd Conv. Outlet

4

Johnson Controls Unitary Products

Image 4
Contents Technical Guide Table of Contents Component LocationHeat Pump Ton York Model Number Nomenclature NomenclatureFeatures and Benefits Standard FeaturesFactory Installed Options Control Options Field Installed Accessories Accessories Part Number DescriptionGuide Specifications GeneralIndoor Evaporator FAN Assembly Electric Heating Section if Equipped Reheat Mode Sequence of Operation Reheat Control Board Physical Data ZH078-150 Physical DataFilters ZR078-150 Physical Data Reheat Coil Data XP078-150 Physical Data ZH/ZR/XP078-150 Unit Limitations MinYTG-G-1208 ZH078-150 Cooling Capacities Capacity PerformanceZH078 6.5 Ton 115F ZH090 7.5 Ton ZH090 7.5 Ton ZH102 8.5 Ton ZH102 8.5 Ton ZH120 10 Ton 115F 125F ZH150 12.5 Ton ZH150 12.5 Ton ZR078-150 Cooling and Reheat Capacities ZR078 6.5 Ton Cooling115F ZR078 6.5 Ton Reheat 35F 45FCapacity Input ZR090 7.5 Ton Cooling 115F ZR090 7.5 Ton Reheat 75F 85F ZR102 8.5 Ton Cooling 115F ZR102 8.5 Ton Reheat 75F 85F ZR120 10 Ton Cooling 115F ZR120 10 Ton Reheat 75F 85F ZR150 12.5 Ton Cooling 115F 125F ZR150 12.5 Ton Reheat 75F 85F XP078-150 Cooling Capacities XP078 6.5 Ton115F XP090 7.5 Ton 95F 105F115F 125F XP102 8.5 Ton 115F XP120 10 Ton XP120 10 Ton XP150 12.5 Ton 115F 125F XP078-150 Heating Capacities XP078-150Capacity Outdoor Temperature F @ 72% RH Airflow Performance ZH078-150 Side Duct ApplicationZH078 6.5 Ton Side Duct ZH090 7.5 Ton Side DuctZH120 10 Ton Side Duct ZH150 12.5 Ton Side DuctZH078-150 Bottom Duct Application ZH078 6.5 Ton Bottom DuctZH090 7.5 Ton Bottom Duct ZH102 8.5 Ton Bottom DuctZH120 10 Ton Bottom Duct ZH150 12.5 Ton Bottom DuctZR078-150 Side Duct Application ZR078 6.5 Ton Side DuctZR090 7.5 Ton Side Duct ZR102 8.5 Ton Side DuctZR120 10 Ton Side Duct ZR150 12.5 Ton Side DuctZR078-150 Bottom Duct Application ZR078 6.5 Ton Bottom DuctZR090 7.5 Ton Bottom Duct ZR102 8.5 Ton Bottom DuctZR120 10 Ton Bottom Duct ZR150 12.5 Ton Bottom DuctXP078-150 Side Duct Application XP078 6.5 Ton Side DuctXP090 7.5 Ton Side Duct XP102 8.5 Ton Side DuctXP120 10 Ton Side Duct XP150 12.5 Ton Side DuctXP078-150 Bottom Duct Application XP078 6.5 Ton Bottom DuctXP090 7.5 Ton Bottom Duct XP102 8.5 Ton Bottom DuctXP120 10 Ton Bottom Duct XP150 12.5 Ton Bottom DuctRPM Selection Additional Static Resistance TonsAirflow Performance Drive SelectionAltitude/Temperature Correction Factors Air Temperature ºFFactor CorrectionIndoor Blower Specifications Power Exhaust SpecificationsGas Heat Minimum Supply Air Electric Heat Minimum Supply AirIndoor Sound Power Levels Outdoor Sound Power Levels ZH/ZR/XP078-150Sound Performance Electric Heat MultipliersZH078-150 Standard Motor Without Powered Convenience Outlet Electrical DataZH078-150 Standard Motor Without Powered Convenience Outlet ZH078-150 Hi Static Motor Without Powered Convenience Outlet ZH078-150 Hi Static Motor Without Powered Convenience Outlet ZH078-150 Standard Motor With Powered Convenience Outlet ZH078-150 Standard Motor With Powered Convenience Outlet ZH078-150 Hi Static Motor With Powered Convenience Outlet ZH078-150 Hi Static Motor With Powered Convenience Outlet ZR078-150 Standard Motor Without Powered Convenience Outlet ZR078-150 Standard Motor Without Powered Convenience Outlet ZR078-150 Hi Static Motor Without Powered Convenience Outlet ZR078-150 Hi Static Motor Without Powered Convenience Outlet ZR078-150 Standard Motor With Powered Convenience Outlet ZR078-150 Standard Motor With Powered Convenience Outlet ZR078-150 Hi Static Motor With Powered Convenience Outlet ZR078-150 Hi Static Motor With Powered Convenience Outlet XP078-150 Standard Motor Without Powered Convenience Outlet XP078-150 Standard Motor Without Powered Convenience Outlet XP078-150 Hi Static Motor Without Powered Convenience Outlet Johnson Controls Unitary Products 101 XP078-150 Standard Motor With Powered Convenience Outlet Johnson Controls Unitary Products 103 XP078-150 Hi Static Motor With Powered Convenience Outlet Johnson Controls Unitary Products 105 Typical Wiring Diagrams ZH/ZR078-150 Typical Wiring DiagramsJohnson Controls Unitary Products 107 108 Johnson Controls Unitary Products Johnson Controls Unitary Products 109 110 Johnson Controls Unitary Products Johnson Controls Unitary Products 111 Typical ZR078-120 Reheat Wiring Diagram Typical ZR150 Reheat Wiring Diagram XP078-150 Typical Wiring Diagrams Johnson Controls Unitary Products 115 ZH/ZR/XP078-150 Unit Weights Weights and DimensionsUnit 4 Point Load Weight Unit 6 Point Load Weight ZH/ZR/XP078-150 Unit Accessory Weights ZH/ZR/XP078-150 Unit DimensionsZH/ZR/XP078-120 ZH/ZR/XP078-150 Unit Physical Dimensions Detail aZH/ZR/XP078-150 Unit Clearances ZH/ZR/XP078-150 Unit Bottom Duct OpeningsZH/ZR/XP078-150 Unit Electrical Entry ZH/ZR/XP078-120 Unit Side Duct OpeningsZH/ZR/XP150 Unit Side Duct Openings Side Duct DimensionsZH/ZR/XP078-150 Unit Left Duct Opening ZH/ZR/XP078-150 Roof Curb ZH/ZR/XP078-150 Unit Accessory DimensionsZH/ZR/XP078-150 Transition Roof Curb ZH/ZR/XP078-150 Economizer Assembly Factory Installed Downflow Economizer Field Installed Downflow Economizer W/Power ExhaustEconomizer Options Economizer UsageField Installed Horizontal Economizer W/Power Exhaust Slab Economizer Downflow W/Power ExhaustSlab Economizer End Return W/Power Exhaust 126 Johnson Controls Unitary Products YTG-G-1208 Johnson Controls Unitary Products 127 Johnson Controls Unitary Products York Drive Norman, OK
Related manuals
Manual 24 pages 22.74 Kb Manual 68 pages 3.65 Kb Manual 104 pages 7.39 Kb Manual 36 pages 24.83 Kb

R-410A specifications

York R-410A is a widely recognized and highly efficient refrigerant used in modern air conditioning systems. Developed as an environmentally friendly alternative to R-22, R-410A has gained popularity in the HVAC industry due to its numerous advantageous features and characteristics.

One of the main features of York R-410A is its ability to provide superior cooling performance. This refrigerant operates efficiently at both high and low temperatures, allowing systems using it to maintain optimal indoor climates even during extreme weather conditions. Its high energy efficiency ratio (EER) and seasonal energy efficiency ratio (SEER) ratings make it a preferred choice for energy-conscious consumers, resulting in lower energy bills and a reduced carbon footprint.

Technologically, York R-410A systems feature advanced compressor designs that enhance their overall reliability and performance. These compressors are often equipped with variable-speed technology, enabling them to adjust their output to match the cooling demands of the space. This not only improves comfort levels but also leads to efficient energy consumption, reducing wear and tear on the equipment over time.

Another significant characteristic of York R-410A is its non-ozone-depleting properties. Unlike its predecessor R-22, which is being phased out due to its damaging effects on the ozone layer, R-410A is designed to minimize environmental impact. Its lower global warming potential (GWP) further underscores its role in promoting sustainability within the HVAC sector.

Furthermore, York R-410A systems are engineered with enhanced safety features. The refrigerant is non-toxic and non-flammable, which makes it safer for use in both residential and commercial applications. Additionally, its high thermal stability reduces the risk of breakdown or leakage, contributing to longer system lifespans and lower maintenance costs.

In conclusion, York R-410A stands out as a cutting-edge refrigerant that combines efficiency, safety, and environmental responsibility. With its advanced technologies and remarkable characteristics, it meets the demands of modern air conditioning requirements while paving the way for a sustainable future in HVAC systems. Adopting York R-410A not only benefits individual users through improved comfort and lower energy bills but also plays a vital role in protecting our planet's ozone layer and mitigating climate change.