York R-410A manual Features and Benefits, Standard Features

Page 5

246824-YTG-G-1208

Features and Benefits

Standard Features

High Efficiency – High efficiency units reach as high as 11.5 EER. Gas/electric units have electronic spark ignition and power vented combustion with steady state efficiencies

of 80%. These efficiencies exceed all legislated minimum

levels and provide low operating costs.

Service Friendly – The Predator® incorporates a number of enhancements which improve serviceability.

The motor and blower slide out of the unit as a common assembly. This facilitates greater access to all the indoor airflow components, thus simplifying maintenance and adjustment.

Service time is reduced through the use of hinged, toolless panels. Such panels provide access to frequently inspected components and areas, including the control box, compressors, filters, indoor motor & blower, and the heating section. The panels are screwed in place at the factory to prevent access by children or other unauthorized persons. It is recommended that the panels be secured with screws once service is complete.

Service windows have been placed in both condenser section walls. Rotation of the cover allows easy access to the condenser coils for cleaning or inspection.

Both the unit control board and ignition control board utilize flash codes to aid in diagnosis of unit malfunctions. Unique alarm codes quickly identify the source of the unit alarm.

All units use the same standard filter size. This standardization removes any confusion on which filter sizes are needed for replacement.

The non-corrosive drain pan slides out of the unit to permit easy cleaning. The drain pan is accessed by removing the drain pan cover plate on the rear of the unit. Once the plate is removed, the drain pan slides out through the rear of the unit. All Predator® units have a second model nameplate located inside the control access door. This is to prevent deterioration of the nameplate through weathering.

Environmentally Aware – For improved Indoor Air Quality, foil faced insulation is used exclusively throughout the units.

Balanced Heating – The Predator® offers “Ultimate Heating Comfort” with a balance between 1st and 2nd stage gas heating. The first stage of a gas heat Predator® unit provides 60% of the heating capacity. Balanced heating allows the unit to better maintain desired temperatures.

Convertible Airflow Design – The side duct openings are covered when they leave the factory. If a side supply/ return is desired, the installer simply removes the two side duct covers from the outside of the unit and installs them over the down shot openings. No panel cutting is required. Convertible airflow design allows maximum field flexibility and minimum inventory.

System Protection - Suction line freezestats are supplied on all units to protect against loss of charge and coil frosting when the economizer operates at low outdoor air temperatures while the compressors are running. Every unit has solid-core liquid line filter-driers and high and low-

pressure switches. Internal compressor protection is standard on all compressors. Crankcase heaters are standard on reciprocating compressors. Scroll compressors do not require crankcase heaters. Phase Monitors are standard on units with scroll compressors. This accessory monitors the incoming power to the unit and protects the unit from phase loss and reversed phase rotation.

Advanced Controls - Simplicity® control boards have standardized a number of features previously available only as options or by utilizing additional controls.

Low Ambient - An integrated low-ambient control allows all units to operate in the cooling mode down to 0°F outdoor ambient without additional assistance. Optionally, the control board can be programmed to lockout the compressors when the outdoor air temper- ature is low or when free cooling is available.

The Simplicity® control board used in this product will effectively operate the cooling system down to 0°F when this product is applied in a comfort cooling application for people. An economizer is typically included in this type of application. When applying this product for process cooling applications (com- puter rooms, switchgear, etc.), please reference applications bulletin AE-011-07 or call the applica- tions department for Unitary Products @ 1-877- UPG-SERV for guidance. Additional accessories may be needed for stable operation at temperatures below 30° F.

Anti-Short Cycle Protection - To aid compressor life, an anti-short cycle delay is incorporated into the stan- dard controls. Compressor reliability is further ensured by programmable minimum run times. For testing, the anti-short cycle delay can be temporarily overridden with the push of a button.

Fan Delays - Fan on and fan off delays are fully pro- grammable. Furthermore, the heating and cooling fan delay times are independent of one another. All units are programmed with default values based upon their configuration of cooling and heat.

Safety Monitoring - The control board monitors the high and low-pressure switches, the freezestats, the gas valve, if applicable, and the temperature limit switch on gas and electric heat units. The unit control board will alarm on ignition failures, compressor lock- outs and repeated limit switch trips.

Nuisance Trip Protection and Strikes - To prevent nuisance trouble calls, the control board uses a “three times, you’re out” philosophy. The high and low-pres- sure switches and the freezestats must trip three times within two hours before the unit control board will lock out the associated compressor.

On Board Diagnostics - Each alarm will energize a trouble light on the thermostat, if so equipped, and

Johnson Controls Unitary Products

5

Image 5
Contents Technical Guide Component Location Table of ContentsHeat Pump Nomenclature Ton York Model Number NomenclatureStandard Features Features and BenefitsFactory Installed Options Control Options Field Installed Accessories Part Number Description AccessoriesGeneral Guide SpecificationsIndoor Evaporator FAN Assembly Electric Heating Section if Equipped Reheat Mode Sequence of Operation Reheat Control Board ZH078-150 Physical Data Physical DataFilters ZR078-150 Physical Data Reheat Coil Data XP078-150 Physical Data Min ZH/ZR/XP078-150 Unit LimitationsYTG-G-1208 ZH078 6.5 Ton Capacity PerformanceZH078-150 Cooling Capacities 115F ZH090 7.5 Ton ZH090 7.5 Ton ZH102 8.5 Ton ZH102 8.5 Ton ZH120 10 Ton 115F 125F ZH150 12.5 Ton ZH150 12.5 Ton ZR078 6.5 Ton Cooling ZR078-150 Cooling and Reheat Capacities115F 35F 45F ZR078 6.5 Ton ReheatCapacity Input ZR090 7.5 Ton Cooling 115F ZR090 7.5 Ton Reheat 75F 85F ZR102 8.5 Ton Cooling 115F ZR102 8.5 Ton Reheat 75F 85F ZR120 10 Ton Cooling 115F ZR120 10 Ton Reheat 75F 85F ZR150 12.5 Ton Cooling 115F 125F ZR150 12.5 Ton Reheat 75F 85F XP078 6.5 Ton XP078-150 Cooling Capacities115F 95F 105F XP090 7.5 Ton115F 125F XP102 8.5 Ton 115F XP120 10 Ton XP120 10 Ton XP150 12.5 Ton 115F 125F XP078-150 XP078-150 Heating CapacitiesCapacity Outdoor Temperature F @ 72% RH ZH078-150 Side Duct Application Airflow PerformanceZH078 6.5 Ton Side Duct ZH090 7.5 Ton Side DuctZH150 12.5 Ton Side Duct ZH120 10 Ton Side DuctZH078 6.5 Ton Bottom Duct ZH078-150 Bottom Duct ApplicationZH090 7.5 Ton Bottom Duct ZH102 8.5 Ton Bottom DuctZH150 12.5 Ton Bottom Duct ZH120 10 Ton Bottom DuctZR078 6.5 Ton Side Duct ZR078-150 Side Duct ApplicationZR090 7.5 Ton Side Duct ZR102 8.5 Ton Side DuctZR150 12.5 Ton Side Duct ZR120 10 Ton Side DuctZR078 6.5 Ton Bottom Duct ZR078-150 Bottom Duct ApplicationZR090 7.5 Ton Bottom Duct ZR102 8.5 Ton Bottom DuctZR150 12.5 Ton Bottom Duct ZR120 10 Ton Bottom DuctXP078 6.5 Ton Side Duct XP078-150 Side Duct ApplicationXP090 7.5 Ton Side Duct XP102 8.5 Ton Side DuctXP150 12.5 Ton Side Duct XP120 10 Ton Side DuctXP078 6.5 Ton Bottom Duct XP078-150 Bottom Duct ApplicationXP090 7.5 Ton Bottom Duct XP102 8.5 Ton Bottom DuctXP150 12.5 Ton Bottom Duct XP120 10 Ton Bottom DuctRPM Selection Tons Additional Static ResistanceDrive Selection Airflow PerformanceAir Temperature ºF Altitude/Temperature Correction FactorsFactor CorrectionPower Exhaust Specifications Indoor Blower SpecificationsGas Heat Minimum Supply Air Electric Heat Minimum Supply AirOutdoor Sound Power Levels ZH/ZR/XP078-150 Indoor Sound Power LevelsSound Performance Electric Heat MultipliersElectrical Data ZH078-150 Standard Motor Without Powered Convenience OutletZH078-150 Standard Motor Without Powered Convenience Outlet ZH078-150 Hi Static Motor Without Powered Convenience Outlet ZH078-150 Hi Static Motor Without Powered Convenience Outlet ZH078-150 Standard Motor With Powered Convenience Outlet ZH078-150 Standard Motor With Powered Convenience Outlet ZH078-150 Hi Static Motor With Powered Convenience Outlet ZH078-150 Hi Static Motor With Powered Convenience Outlet ZR078-150 Standard Motor Without Powered Convenience Outlet ZR078-150 Standard Motor Without Powered Convenience Outlet ZR078-150 Hi Static Motor Without Powered Convenience Outlet ZR078-150 Hi Static Motor Without Powered Convenience Outlet ZR078-150 Standard Motor With Powered Convenience Outlet ZR078-150 Standard Motor With Powered Convenience Outlet ZR078-150 Hi Static Motor With Powered Convenience Outlet ZR078-150 Hi Static Motor With Powered Convenience Outlet XP078-150 Standard Motor Without Powered Convenience Outlet XP078-150 Standard Motor Without Powered Convenience Outlet XP078-150 Hi Static Motor Without Powered Convenience Outlet Johnson Controls Unitary Products 101 XP078-150 Standard Motor With Powered Convenience Outlet Johnson Controls Unitary Products 103 XP078-150 Hi Static Motor With Powered Convenience Outlet Johnson Controls Unitary Products 105 ZH/ZR078-150 Typical Wiring Diagrams Typical Wiring DiagramsJohnson Controls Unitary Products 107 108 Johnson Controls Unitary Products Johnson Controls Unitary Products 109 110 Johnson Controls Unitary Products Johnson Controls Unitary Products 111 Typical ZR078-120 Reheat Wiring Diagram Typical ZR150 Reheat Wiring Diagram XP078-150 Typical Wiring Diagrams Johnson Controls Unitary Products 115 Unit 4 Point Load Weight Unit 6 Point Load Weight Weights and DimensionsZH/ZR/XP078-150 Unit Weights ZH/ZR/XP078-120 ZH/ZR/XP078-150 Unit DimensionsZH/ZR/XP078-150 Unit Accessory Weights Detail a ZH/ZR/XP078-150 Unit Physical DimensionsZH/ZR/XP078-150 Unit Clearances ZH/ZR/XP078-150 Unit Bottom Duct OpeningsZH/ZR/XP078-120 Unit Side Duct Openings ZH/ZR/XP078-150 Unit Electrical EntryZH/ZR/XP078-150 Unit Left Duct Opening Side Duct DimensionsZH/ZR/XP150 Unit Side Duct Openings ZH/ZR/XP078-150 Transition Roof Curb ZH/ZR/XP078-150 Unit Accessory DimensionsZH/ZR/XP078-150 Roof Curb ZH/ZR/XP078-150 Economizer Assembly Field Installed Downflow Economizer W/Power Exhaust Factory Installed Downflow EconomizerEconomizer Options Economizer UsageSlab Economizer Downflow W/Power Exhaust Field Installed Horizontal Economizer W/Power ExhaustSlab Economizer End Return W/Power Exhaust 126 Johnson Controls Unitary Products YTG-G-1208 Johnson Controls Unitary Products 127 Johnson Controls Unitary Products York Drive Norman, OK
Related manuals
Manual 24 pages 22.74 Kb Manual 68 pages 3.65 Kb Manual 104 pages 7.39 Kb Manual 36 pages 24.83 Kb

R-410A specifications

York R-410A is a widely recognized and highly efficient refrigerant used in modern air conditioning systems. Developed as an environmentally friendly alternative to R-22, R-410A has gained popularity in the HVAC industry due to its numerous advantageous features and characteristics.

One of the main features of York R-410A is its ability to provide superior cooling performance. This refrigerant operates efficiently at both high and low temperatures, allowing systems using it to maintain optimal indoor climates even during extreme weather conditions. Its high energy efficiency ratio (EER) and seasonal energy efficiency ratio (SEER) ratings make it a preferred choice for energy-conscious consumers, resulting in lower energy bills and a reduced carbon footprint.

Technologically, York R-410A systems feature advanced compressor designs that enhance their overall reliability and performance. These compressors are often equipped with variable-speed technology, enabling them to adjust their output to match the cooling demands of the space. This not only improves comfort levels but also leads to efficient energy consumption, reducing wear and tear on the equipment over time.

Another significant characteristic of York R-410A is its non-ozone-depleting properties. Unlike its predecessor R-22, which is being phased out due to its damaging effects on the ozone layer, R-410A is designed to minimize environmental impact. Its lower global warming potential (GWP) further underscores its role in promoting sustainability within the HVAC sector.

Furthermore, York R-410A systems are engineered with enhanced safety features. The refrigerant is non-toxic and non-flammable, which makes it safer for use in both residential and commercial applications. Additionally, its high thermal stability reduces the risk of breakdown or leakage, contributing to longer system lifespans and lower maintenance costs.

In conclusion, York R-410A stands out as a cutting-edge refrigerant that combines efficiency, safety, and environmental responsibility. With its advanced technologies and remarkable characteristics, it meets the demands of modern air conditioning requirements while paving the way for a sustainable future in HVAC systems. Adopting York R-410A not only benefits individual users through improved comfort and lower energy bills but also plays a vital role in protecting our planet's ozone layer and mitigating climate change.