York 00497VIP manual General Safety Guidelines, Safety Symbols

Page 2

IMPORTANT!

READ BEFORE PROCEEDING!

GENERAL SAFETY GUIDELINES

This equipment is a relatively complicated apparatus. During installation, operation, maintenance or service, individuals may be exposed to certain components or conditions including, but not limited to: refrigerants, oils, materials under pressure, rotating components, and both high and low voltage. Each of these items has the potential, if misused or handled improperly, to cause bodily injury or death. It is the obligation and responsibility of operating/service personnel to identify and recognize these inherent hazards, protect themselves, and proceed safely in completing their tasks. Failure to comply with any of these requirements could result in serious damage to the equipment and the property in which it is situated, as well as severe

personal injury or death to themselves and people at the site.

This document is intended for use by owner-authorized operating/service personnel. It is expected that this individual possesses independent training that will enable them to perform their assigned tasks properly and safely. It is essential that, prior to performing any task on this equipment, this individual shall have read and understood this document and any referenced materials. This individual shall also be familiar with and comply with all applicable governmental standards and regulations pertaining to the task in question.

SAFETY SYMBOLS

The following symbols are used in this document to alert the reader to areas of potential hazard:

DANGER indicates an imminently hazardous situation which, if not avoided, will result in death or seri- ous injury.

WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.

CAUTION identifies a hazard which could lead to damage to the machine, damage to other equip- ment and/or environmental pollu- tion. Usually an instruction will be given, together with a brief explanation.

NOTE is used to highlight additional information which may be helpful to you.

External wiring, unless specified as an optional connection in the manufacturer’s product line, is not to be connected inside the micro panel cabinet. Devices such as relays, switches, transducers and controls may not be installed inside the micro panel. No external wiring is allowed to be run through the micro panel. All wiring must be in accordance with YORK’s published specifications and must be performed only by qualified YORK personnel. YORK will not be responsible for damages/problems resulting from improper connections to the controls or application of improper control signals. Failure to follow this will void the manufacturer’s warranty and cause serious damage to property or injury to persons.

2

YORK INTERNATIONAL

Image 2
Contents Remote Control Center Optiview Remote Control CenterGeneral Safety Guidelines Safety SymbolsChangeability of this Document Table of Contents List of Tables List of Figures EU Declaration of Conformity Product Description CHILLER/CONDENSING Control Panels Installation Required Software Version Chiller / Condensing Unit Eproms Optiview Remote Control Center From Optiview RCC Unit Microboard 031-01314-000 031-02050-001 Unit MicroboardWire Sizing Voltage Source FigureGrounding Ground Wire Size FigureWiring Practices Figure Do not drill a control panel to locate conduit con Sides or bottom of the panel and use a conduit drainOperation Setpoints Screen Descriptions and UsageSetpoint / Change Schedule Manual ControlsScreen Navigation Layout This page intentionally left blank to maintain formatting Unit Type Unit Control TemperatureHome Screen Unit StatusUnit # Unit Run Indicator LEDAverage Ambient Temperature Unit Screen Examples Ycal ChillerYcas Chiller Ycws Chiller Unit Screen This page intentionally left blank Systems Screen Examples 00507VIPC Systems Screen Individual System Screen None Hours and Starts Screen Total Starts Operating HoursOptions Screen Ycas Chiller / Ycar ChillerLocal/Remote Control Mode Units Display ModeAmbient Control Mode Language Display ModeTrending Screen TrendingStop Trend SetupStart AxisCollection Interval Trend Setup ScreenChart Type Data Point Min SelectData Point Slot # Data Point MaxThis page intentionally left blank This page intentionally left blank Setpoints Screen Examples 00517VIPC Setpoints Screen Print History Last FaultsHistory Screen Print All HistoriesDown History Details ScreenHistory Printout Number of Units Connected SetupRCC Setpoints Screen Set Date RCC Setup ScreenClock Enabled / Disabled Set TimeComms DiagnosticsUnits PrinterRCC Poll Time 5-30 sec Comms ScreenRS-485 Baud Rate Printer Screen RCC Comms Diagnostics ScreenSoftware Versions Diagnostics I/O Screen Digital InputsDiagnostics RCC Comms Screen Timeout Count Clear CountersDisplay Messages Status MessagesPrinters PrintersSeiko Equipped with an RS-232 Serial interface OkidataWeigh-Tronix Models 2600 Okidata 182, 182 turbo, 184 turboWEIGH-TRONIX Printer ConnectorsHardware required ModelPrinter Setup Automatic Data LoggingLocal/Remote Control Mode Suction Temperature = 42.9 F Discharge Temperature Service IntroductionSystem Architecture Refer to FIGControl Center Microboard Refer toMini-card signature test Fpga configurationFirst initiate table complete Mini-card checksumService York International Bios Eprom U45 Flash Memory Card Bram Bios Eprom Flash Memory Card From Watchdog protection as follows Pins 1-2 RS-232 Pins 2-3 RS-485 JP10 JP26 Not usedMicroboard Program Jumpers JP34, JP35, JP36, JP37 Not Used JP39, JP40, JP41, JP42 Not usedMicroboard Program Switches Tion! Severe compressor or chillerMicroboard Serial Data Communications Ports Configurable Analog Inputs Liquid Crystal Display Ment Displays or supporting components cannot beDisplay Replacement Kit LG Semicon LP104V2 Display refer to Removal InstallationSharp LQ10D367 Display Refer to Removal DISPLAY, Mounting Liquid Crystal Display Assembly LG Semicon LP104V2 Display Sharp LQ10D367 Lamp Replacement 031-01765-002 Display Interface Board031-01765-001 Display Interface Board Display Backlight Inverter Board Inverter Keypad Refer to Figures 45Keypad LD04075 Power Supply Power Supply Offline Diagnostics & Troubleshooting Refer toMain Diagnostics Screen Keypad Test Procedure Display TestBIT Patterns Test Screen RS-485 From Serial Inputs / Outputs TestsFrom From COM 4b102 Digital Inputs / Outputs Tests Analog Inputs Tests System Commissioning Checklist Part Number and Renewal Parts 107 108 109 SI Metric Conversion 110Page ALL Rights Reserved

00497VIP specifications

York 00497VIP is an innovative system designed to enhance efficiency and comfort in residential and light commercial environments. Central to its appeal is its commitment to energy efficiency and environmentally friendly operation, making it a popular choice for those looking to reduce their carbon footprint.

One of the standout features of the York 00497VIP is its advanced variable speed compressor technology. This technology allows the system to adjust its cooling and heating output based on real-time demand, leading to significant energy savings. Unlike traditional systems that often operate at a single speed, the variable speed compressor modulates its output to maintain a consistent indoor climate, ensuring optimal comfort while minimizing energy consumption.

The system is equipped with a high-efficiency air handler that enhances airflow, ensuring that every corner of the space benefits from consistent temperature control. Its unique design facilitates quiet operation, making it ideal for residential spaces where noise levels need to be kept to a minimum. This whisper-quiet functioning doesn’t compromise power, as the air handler is designed to work collaboratively with the compressor to deliver efficient cooling or heating throughout the home.

York has integrated smart technology into the 00497VIP, allowing homeowners to control the system remotely via smartphone applications. This feature not only adds convenience but also enables users to monitor energy usage and adjust settings from anywhere, enhancing the possibility of energy savings.

The system also boasts advanced filtration capabilities, utilizing a multi-stage filtration system to capture dust, allergens, and other airborne particles. This technology improves indoor air quality, promoting a healthier living environment.

In terms of adaptability, the York 00497VIP is compatible with a range of smart home systems, seamlessly integrating into existing setups. This flexibility extends to its installation, as it can be tailored to fit various spaces without significant modifications to the existing infrastructure.

Built to withstand diverse environmental conditions, the York 00497VIP is constructed with durable materials, ensuring longevity and reliable performance. This combination of efficiency, smart features, and adaptability makes it an ideal choice for consumers seeking a sustainable and effective heating and cooling solution for their home or light commercial space.