UNIT SCREEN

OVERVIEW

This screen is accessed from the Home Screen. The primary values of the chiller or condensing unit which must be monitored and controlled are shown on this screen. The data available depends on the type of unit. This screen display depicts a visual representation of the unit itself. Animation indicates chilled liquid flow and condenser fans running.

DISPLAY ONLY

Systems Statuses

Displays the individual refrigerant systems operational statuses. The messages displayed include running status, cooling demand, fault status, external cycling device status, load limiting, and anti-recycle timer status. The status message that is displayed on the microprocessor is represented here.

System Run (LED)

Is ON when the individual refrigerant systems compres- sor is running. If any of these are ON, the fans will be animated to show that they are running.

Slide Valve Step (If Screw)

Displays the individual refrigerant systems slide valve step.

Load Stage (If Recip)

Indicates the number of solenoids on the compressor of a YCAR unit that are de-energized and loaded.

Number Of Compressors Running (If a system has more than one)

Displays how many compressors are running on the unit.

System Run Time

Displays the individual refrigerant systems logged run time since the last compressor start, in days (Days), hours (Hr), minutes (Min) or seconds (Sec).

Lead System

This message indicates which system is in the lead.

Evaporator Pump Contact (LED)

Is ON when the evaporator pump signal from the microprocessor is on. If this is ON, the chilled liquid will be animated to show that it is flowing.

Evaporator Heater (LED)

Is ON when the evaporator heater signal from the microprocessor is on.

Leaving Chilled Liquid Temperature

Displays the temperature of the liquid as it leaves the evaporator.

Return Chilled Liquid Temperature

Displays the temperature of the liquid as it enters the evaporator.

Discharge Air Temperature

Displays the discharge air temperature leaving the evaporator when the condensing unit is programmed for Discharge Air control.

Systems Suction Pressure

Displays the suction pressure for each individual system on a condensing unit when the unit was programmed for Suction Pressure control.

Ambient Temperature

Displays the outdoor Ambient Air Temperature.

PROGRAMMABLE

Print

Initiates a printout of current system operating parameters for the currently selected unit.

Cancel Print

Terminates the printing in process. This key is only visible while printing is in process.

NAVIGATION

Home

Causes an instant return to the Home Screen.

System Data

Used to provide additional system information.

Hours/Starts

This screen shows the cumulative operating hours and start count of each compressor.

Options

Used to provide information of the options that were programmed at the Unit Control Panel.

Trending

This screen provides the user a view of trending data on selected parameters of this chiller/condensing unit.

Setpoints

This screen provides a single location to program the unit setpoints for the selected unit.

History

This screen provides access to a snapshot of system data at each of the last 4-6 shutdown conditions.

YORK INTERNATIONAL

27

Image 27
Contents Optiview Remote Control Center Remote Control CenterSafety Symbols General Safety GuidelinesChangeability of this Document Table of Contents List of Tables List of Figures EU Declaration of Conformity Product Description CHILLER/CONDENSING Control Panels Installation Required Software Version Chiller / Condensing Unit Eproms Optiview Remote Control Center From Optiview RCC Unit Microboard Unit Microboard 031-01314-000 031-02050-001Voltage Source Figure Wire SizingGround Wire Size Figure Wiring Practices FigureGrounding Sides or bottom of the panel and use a conduit drain Do not drill a control panel to locate conduit conOperation Manual Controls Screen Descriptions and UsageSetpoint / Change Schedule SetpointsScreen Navigation Layout This page intentionally left blank to maintain formatting Unit Status Unit Control TemperatureHome Screen Unit TypeUnit Run Indicator LED Average Ambient TemperatureUnit # Ycal Chiller Unit Screen ExamplesYcas Chiller Ycws Chiller Unit Screen This page intentionally left blank Systems Screen Examples 00507VIPC Systems Screen Individual System Screen None Hours and Starts Screen Operating Hours Total StartsYcas Chiller / Ycar Chiller Options ScreenLanguage Display Mode Units Display ModeAmbient Control Mode Local/Remote Control ModeTrending Trending ScreenAxis Trend SetupStart StopTrend Setup Screen Chart TypeCollection Interval Data Point Max SelectData Point Slot # Data Point MinThis page intentionally left blank This page intentionally left blank Setpoints Screen Examples 00517VIPC Setpoints Screen Print All Histories Last FaultsHistory Screen Print HistoryHistory Details Screen History PrintoutDown Setup RCC Setpoints ScreenNumber of Units Connected Set Time RCC Setup ScreenClock Enabled / Disabled Set DatePrinter DiagnosticsUnits CommsComms Screen RS-485 Baud RateRCC Poll Time 5-30 sec Printer Screen Diagnostics Screen Software VersionsRCC Comms Digital Inputs Diagnostics I/O ScreenDiagnostics RCC Comms Screen Clear Counters Timeout CountStatus Messages Display MessagesPrinters PrintersOkidata 182, 182 turbo, 184 turbo Equipped with an RS-232 Serial interface OkidataWeigh-Tronix Models 2600 SeikoModel ConnectorsHardware required WEIGH-TRONIX PrinterAutomatic Data Logging Printer SetupLocal/Remote Control Mode Suction Temperature = 42.9 F Discharge Temperature Introduction ServiceRefer to FIG System ArchitectureControl Center Refer to MicroboardMini-card checksum Fpga configurationFirst initiate table complete Mini-card signature testService York International Bios Eprom U45 Flash Memory Card Bram Bios Eprom Flash Memory Card From Pins 1-2 RS-232 Pins 2-3 RS-485 JP10 JP26 Not used Microboard Program JumpersWatchdog protection as follows JP39, JP40, JP41, JP42 Not used JP34, JP35, JP36, JP37 Not UsedTion! Severe compressor or chiller Microboard Program SwitchesMicroboard Serial Data Communications Ports Configurable Analog Inputs Ment Displays or supporting components cannot be Liquid Crystal DisplayDisplay Replacement Kit Installation Sharp LQ10D367 Display Refer to RemovalLG Semicon LP104V2 Display refer to Removal DISPLAY, Mounting Liquid Crystal Display Assembly LG Semicon LP104V2 Display Sharp LQ10D367 Lamp Replacement Display Interface Board 031-01765-001031-01765-002 Display Interface Board Display Backlight Inverter Board Inverter Refer to Figures 45 KeypadKeypad LD04075 Power Supply Power Supply Refer to Offline Diagnostics & TroubleshootingMain Diagnostics Screen Keypad Test Display Test ProcedureBIT Patterns Test Screen From COM 4b Serial Inputs / Outputs TestsFrom RS-485 From102 Digital Inputs / Outputs Tests Analog Inputs Tests System Commissioning Checklist Part Number and Renewal Parts 107 108 109 110 SI Metric ConversionPage ALL Rights Reserved

00497VIP specifications

York 00497VIP is an innovative system designed to enhance efficiency and comfort in residential and light commercial environments. Central to its appeal is its commitment to energy efficiency and environmentally friendly operation, making it a popular choice for those looking to reduce their carbon footprint.

One of the standout features of the York 00497VIP is its advanced variable speed compressor technology. This technology allows the system to adjust its cooling and heating output based on real-time demand, leading to significant energy savings. Unlike traditional systems that often operate at a single speed, the variable speed compressor modulates its output to maintain a consistent indoor climate, ensuring optimal comfort while minimizing energy consumption.

The system is equipped with a high-efficiency air handler that enhances airflow, ensuring that every corner of the space benefits from consistent temperature control. Its unique design facilitates quiet operation, making it ideal for residential spaces where noise levels need to be kept to a minimum. This whisper-quiet functioning doesn’t compromise power, as the air handler is designed to work collaboratively with the compressor to deliver efficient cooling or heating throughout the home.

York has integrated smart technology into the 00497VIP, allowing homeowners to control the system remotely via smartphone applications. This feature not only adds convenience but also enables users to monitor energy usage and adjust settings from anywhere, enhancing the possibility of energy savings.

The system also boasts advanced filtration capabilities, utilizing a multi-stage filtration system to capture dust, allergens, and other airborne particles. This technology improves indoor air quality, promoting a healthier living environment.

In terms of adaptability, the York 00497VIP is compatible with a range of smart home systems, seamlessly integrating into existing setups. This flexibility extends to its installation, as it can be tailored to fit various spaces without significant modifications to the existing infrastructure.

Built to withstand diverse environmental conditions, the York 00497VIP is constructed with durable materials, ensuring longevity and reliable performance. This combination of efficiency, smart features, and adaptability makes it an ideal choice for consumers seeking a sustainable and effective heating and cooling solution for their home or light commercial space.