York 00497VIP manual Local/Remote Control Mode

Page 63

York International Corporation

Unit X Status

X Comp Screw

2:04PM 18 JUN 01

System 1 No Cooling Load

System 2 Compressor Running

System 3 No Cooling Load

System 4 Compressor Running

Options

Chilled Liquid Type

= Water

 

Ambient Control Mode

= Standard

Refrigerant Type

= R-22

 

Program Values

 

 

 

Current Limit Setpoint

= 100 %

 

Local/Remote Control Mode

= Remote

 

Unit Data

 

 

 

Leaving Chilled Liquid Temperature

= 49.0 °F

Return Chilled Liquid Temperature

= 58.2 °F

Leaving Chilled Liquid Setpoint

= 20.0 °F

Control Range

= 2.0 °F

 

Ambient Temerature

= 74.8 °F

Lead System

= 2

 

 

Evaporator Pump Contact

= On

 

Evaporator Heater

= Off

 

Software Version

= C.ACS.09.03

System 1 Data

 

 

 

System Run

= Off

 

System Run Time

=

0

Min

Motor Current (%FLA)

=

0

%

Suction Pressure

= 125.4

Psig

Discharge Pressure

= 131.3

Psig

Oil Pressure

= 130.6

Psig

Suction Temperature

=

68.4

°F

Discharge Temperature

=

68.8

°F

Oil Temperature

=

68.8

°F

Saturated Suction Temp

=

71.8

°F

Suction Superheat

=

3.4

°F

Saturated Discharge Temp

=

74.5

°F

Discharge Superheat

=

6.3

°F

Slide Valve Step

=

0

 

Cooler Inlet Refrig Temp

=

44.6

°F

FORM 50.40-OM2

Liquid Line Solenoid

= On

 

 

Economizer Solenoid

= Off

 

 

Condenser Fan Stage

=

0

 

 

Compressor Heater

= On

 

 

System 2 Data

 

 

 

 

System Run

= On

 

 

System Run Time

=

15

Min

 

Motor Current (%FLA)

=

87

%

 

Suction Pressure

=

57.2

Psig

 

Discharge Pressure

= 233.1

Psig

 

Oil Pressure

= 218.0

Psig

 

Suction Temperature

=

42.9

°F

 

Discharge Temperature

= 145.5

°F

 

Oil Temperature

= 102.8

°F

 

Saturated Suction Temp

=

31.7

°F

 

Suction Superheat

=

11.2

°F

 

Saturated Discharge Temp

= 112.1

°F

 

Discharge Superheat

=

33.4

°F

 

Slide Valve Step

=

70

 

 

Cooler Inlet Refrig Temp

=

23.6

°F

 

Liquid Line Solenoid

= On

 

 

Economizer Solenoid

= On

 

 

Condenser Fan Stage

=

3

 

 

Compressor Heater

= Off

 

 

System 3 Data

 

 

 

4

System Run

= Off

 

 

System Run Time

=

0

Min

 

Motor Current (%FLA)

=

0

%

 

Suction Pressure

= 125.4

Psig

 

Discharge Pressure

= 131.3

Psig

 

Oil Pressure

= 130.6

Psig

 

Suction Temperature

=

68.4

°F

 

Discharge Temperature

=

68.8

°F

 

Oil Temperature

=

68.8

°F

 

Saturated Suction Temp

=

71.8

°F

 

Suction Superheat

=

3.4

°F

 

Saturated Discharge Temp

=

74.5

°F

 

Discharge Superheat

=

6.3

°F

 

Slide Valve Step

=

0

 

 

Cooler Inlet Refrig Temp

=

44.6

°F

 

Liquid Line Solenoid

= Off

 

 

Economizer Solenoid

= Off

 

 

Condenser Fan Stage

=

0

 

 

Compressor Heater

= On

 

 

 

 

 

 

 

FIG. 28 – OPERATING DATA PRINTOUT EXAMPLE (YCAS CHILLER)

YORK INTERNATIONAL

63

Image 63
Contents Optiview Remote Control Center Remote Control CenterSafety Symbols General Safety GuidelinesChangeability of this Document Table of Contents List of Tables List of Figures EU Declaration of Conformity Product Description CHILLER/CONDENSING Control Panels Installation Required Software Version Chiller / Condensing Unit Eproms Optiview Remote Control Center From Optiview RCC Unit Microboard Unit Microboard 031-01314-000 031-02050-001Voltage Source Figure Wire SizingGround Wire Size Figure Wiring Practices FigureGrounding Sides or bottom of the panel and use a conduit drain Do not drill a control panel to locate conduit conOperation Manual Controls Screen Descriptions and UsageSetpoint / Change Schedule SetpointsScreen Navigation Layout This page intentionally left blank to maintain formatting Unit Status Unit Control TemperatureHome Screen Unit TypeUnit Run Indicator LED Average Ambient TemperatureUnit # Ycal Chiller Unit Screen ExamplesYcas Chiller Ycws Chiller Unit Screen This page intentionally left blank Systems Screen Examples 00507VIPC Systems Screen Individual System Screen None Hours and Starts Screen Operating Hours Total StartsYcas Chiller / Ycar Chiller Options ScreenLanguage Display Mode Units Display ModeAmbient Control Mode Local/Remote Control ModeTrending Trending ScreenAxis Trend SetupStart StopTrend Setup Screen Chart TypeCollection Interval Data Point Max SelectData Point Slot # Data Point MinThis page intentionally left blank This page intentionally left blank Setpoints Screen Examples 00517VIPC Setpoints Screen Print All Histories Last FaultsHistory Screen Print HistoryHistory Details Screen History PrintoutDown Setup RCC Setpoints ScreenNumber of Units Connected Set Time RCC Setup ScreenClock Enabled / Disabled Set DatePrinter DiagnosticsUnits CommsComms Screen RS-485 Baud RateRCC Poll Time 5-30 sec Printer Screen Diagnostics Screen Software VersionsRCC Comms Digital Inputs Diagnostics I/O ScreenDiagnostics RCC Comms Screen Clear Counters Timeout CountStatus Messages Display MessagesPrinters PrintersOkidata 182, 182 turbo, 184 turbo Equipped with an RS-232 Serial interface OkidataWeigh-Tronix Models 2600 SeikoModel ConnectorsHardware required WEIGH-TRONIX PrinterAutomatic Data Logging Printer SetupLocal/Remote Control Mode Suction Temperature = 42.9 F Discharge Temperature Introduction ServiceRefer to FIG System ArchitectureControl Center Refer to MicroboardMini-card checksum Fpga configurationFirst initiate table complete Mini-card signature testService York International Bios Eprom U45 Flash Memory Card Bram Bios Eprom Flash Memory Card From Pins 1-2 RS-232 Pins 2-3 RS-485 JP10 JP26 Not used Microboard Program JumpersWatchdog protection as follows JP39, JP40, JP41, JP42 Not used JP34, JP35, JP36, JP37 Not UsedTion! Severe compressor or chiller Microboard Program SwitchesMicroboard Serial Data Communications Ports Configurable Analog Inputs Ment Displays or supporting components cannot be Liquid Crystal DisplayDisplay Replacement Kit Installation Sharp LQ10D367 Display Refer to RemovalLG Semicon LP104V2 Display refer to Removal DISPLAY, Mounting Liquid Crystal Display Assembly LG Semicon LP104V2 Display Sharp LQ10D367 Lamp Replacement Display Interface Board 031-01765-001031-01765-002 Display Interface Board Display Backlight Inverter Board Inverter Refer to Figures 45 KeypadKeypad LD04075 Power Supply Power Supply Refer to Offline Diagnostics & TroubleshootingMain Diagnostics Screen Keypad Test Display Test ProcedureBIT Patterns Test Screen From COM 4b Serial Inputs / Outputs TestsFrom RS-485 From102 Digital Inputs / Outputs Tests Analog Inputs Tests System Commissioning Checklist Part Number and Renewal Parts 107 108 109 110 SI Metric ConversionPage ALL Rights Reserved

00497VIP specifications

York 00497VIP is an innovative system designed to enhance efficiency and comfort in residential and light commercial environments. Central to its appeal is its commitment to energy efficiency and environmentally friendly operation, making it a popular choice for those looking to reduce their carbon footprint.

One of the standout features of the York 00497VIP is its advanced variable speed compressor technology. This technology allows the system to adjust its cooling and heating output based on real-time demand, leading to significant energy savings. Unlike traditional systems that often operate at a single speed, the variable speed compressor modulates its output to maintain a consistent indoor climate, ensuring optimal comfort while minimizing energy consumption.

The system is equipped with a high-efficiency air handler that enhances airflow, ensuring that every corner of the space benefits from consistent temperature control. Its unique design facilitates quiet operation, making it ideal for residential spaces where noise levels need to be kept to a minimum. This whisper-quiet functioning doesn’t compromise power, as the air handler is designed to work collaboratively with the compressor to deliver efficient cooling or heating throughout the home.

York has integrated smart technology into the 00497VIP, allowing homeowners to control the system remotely via smartphone applications. This feature not only adds convenience but also enables users to monitor energy usage and adjust settings from anywhere, enhancing the possibility of energy savings.

The system also boasts advanced filtration capabilities, utilizing a multi-stage filtration system to capture dust, allergens, and other airborne particles. This technology improves indoor air quality, promoting a healthier living environment.

In terms of adaptability, the York 00497VIP is compatible with a range of smart home systems, seamlessly integrating into existing setups. This flexibility extends to its installation, as it can be tailored to fit various spaces without significant modifications to the existing infrastructure.

Built to withstand diverse environmental conditions, the York 00497VIP is constructed with durable materials, ensuring longevity and reliable performance. This combination of efficiency, smart features, and adaptability makes it an ideal choice for consumers seeking a sustainable and effective heating and cooling solution for their home or light commercial space.