York DH 078, 90, 102 manual Factory Installed Downflow Economizer

Page 40

246646-YTG-C-0606

2EE04705424

2EE04705424

2EE04705424

 

 

Fresh Air Hood

Fresh Air Damper

Return Air Damper

2EE04705424

2EE04705424

 

 

Barometric Relief Damper

Barometric Relief Hood

FIGURE 11 - FACTORY INSTALLED DOWNFLOW ECONOMIZER

2EE04705424

2EE04705424

2EE04705424

2PE047032XX

 

Fresh Air Hood

Fresh Air Damper

Return Air Damper

Power Exhaust

 

 

 

 

2EE04705424

2EE04705424

 

 

 

Barometric Relief Damper

Barometric Relief Hood

FIGURE 12 - FIELD INSTALLED DOWNFLOW ECONOMIZER W/POWER EXHAUST

40

Unitary Products Group

Image 40
Contents Technical Guide Ashrae 90.1 CompliantTable of Contents Features All units are shipped with 2 throw-away filters installed Factory Installed Options Field Installed Accessories Low Limit / Compressor Lockout Kit Accessories Part Number Description WeightYTG-C-0606 Ton York Model Number Nomenclature 078 DH Physical Data102 DH Capacity Ratings Unit Voltage LimitationsCFM MBH EER IplvCooling Capacity DH078 6-1/2 TON Unit Cooling Capacity DH090 7-1/2 TON Unit Cooling Capacity DH102 8-1/2 TON Unit Cooling Capacity DH120 10 TON Unit Cooling Capacity DH150 12-1/2 TON Unit Return Dry Bulb F4375 5625MCA RLA LRA FLA RLA LRA FLA MCA Electric Heat Multipliers KW Cap. Multiplier240 480DH078 6-1/2 Side Shot Blower Performance DH090 7-1/2 TON Side Shot Blower Performance CFMDH102 8-1/2 TON Side Shot Blower Performance DH120 10 TON Side Shot Blower Performance DH150 12-1/2 TON Side Shot Blower Performance DH078 6-1/2 TON Down Shot Blower Performance DH090 7-1/2 TON Down Shot Blower Performance DH102 8-1/2 TON Down Shot Blower Performance DH120 10 TON Down Shot Blower Performance DH150 12-1/2 TON Down Shot Blower Performance Additional Static Resistance DH120 Additional Static Resistance DH078, 090Power Exhaust Specifications Indoor Blower SpecificationsElectric Heat Minimum Supply AIR CFM Unit Model Number DH078 DH090 DH102 DH120 Unit WeightModel Shipping Operating Detail a Detail CUnit Clearances DH078 DH090 DH102 DH120Predator Roof Curb Dimensions Rear Duct Dimensions Bottom Duct Openings from AboveDownflow Economizer Hood Detail Economizer Usage Factory Installed Downflow Economizer Field Installed Horizontal Economizer W/POWER Exhaust Slab Economizer END Return W/POWER Exhaust Cooling Unit with GAS Heat Wiring 230 Volt Diagram Cooling Unit WITH/WITHOUT Electric Heat Wiring Diagram YTG-C-0606 General PredatorDescription GAS Heating Section if Equipped Unit Operating CharacteristicsElectric Heating Section if Equipped Additional Factory Installed Options Other PRE-ENGINEERED Accessories Available

102, 90, DH 078 specifications

York DH series chillers, specifically models 078, 90, and 102, are recognized in the HVAC industry for their advanced features, efficiency, and reliability. These chillers are designed to provide exceptional cooling performance for commercial and industrial applications, prioritizing energy efficiency and sustainability.

One of the standout features of the York DH series is its dual-compressor system. This design not only enhances reliability but also contributes to energy savings by allowing the unit to operate at varying loads more effectively. This adaptability ensures that the chillers can maintain optimal performance even during fluctuating demand, reducing energy consumption and associated costs.

The DH series chillers employ a microchannel condenser technology that maximizes heat exchange efficiency. This technology reduces the amount of refrigerant required while also minimizing the footprint of the unit, offering significant advantages in space-constrained environments. Additionally, microchannel coils are less susceptible to corrosion, enhancing the longevity and reliability of the chillers.

Another notable feature is the use of variable-speed drives (VSD) in the compressor system. These drives allow for precise control of the compressor speed, enabling the chillers to adjust to the cooling demands dynamically. This flexibility not only enhances the overall efficiency of the system but also contributes to quieter operation, making the chillers suitable for environments where noise levels are a concern.

York's DH series also integrates advanced controls and monitoring capabilities. The intuitive control system allows for easy programming and operation, providing users with real-time data on system performance and diagnostics. This feature aids in maintenance and troubleshooting, reducing downtime and ensuring that the chillers operate at peak efficiency.

Safety is paramount in the design of the York DH chillers. Each model is equipped with multiple safety features, including pressure relief valves and temperature monitoring systems, to protect the unit during operation. This commitment to safety not only safeguards the equipment but also ensures compliance with industry standards.

In conclusion, the York DH 078, 90, and 102 chillers exemplify modern HVAC technology with their dual-compressor systems, microchannel condenser technology, variable-speed drives, and advanced control systems. These features combine to deliver efficient, reliable, and sustainable cooling solutions for a wide variety of applications. The York DH series represents a significant advancement in chiller design and functionality, making it a preferred choice for many professionals in the field.