York 90, DH 078 Additional Factory Installed Options, Other PRE-ENGINEERED Accessories Available

Page 48

outdoor and return air damper assembly to prevent the supply air temperature from dropping below 55 ºF. Changeover from compressor to economizer operation shall be provided by an integral electronic enthalpy con- trol that feeds input into the basic module. The outdoor intake opening shall be covered with a rain hood that matches the exterior of the unit. Water eliminator/filters shall be provided. Simultaneous economizer/compressor operation is also possible. Dampers shall fully close on power loss. Available with barometric relief or power exhaust.

2.MOTORIZED OUTDOOR AIR DAMPERS – Outdoor and return air dampers that are interlocked and posi- tioned by a 2-position,spring-return damper actuator. The maximum leakage rate for the outdoor air intake dampers shall not exceed 2% when dampers are fully closed and operating against a pressure differential of 0.5 IWG. A unit-mounted potentiometer shall be provided to adjust the outdoor and return air damper assembly to take in the design CFM of outdoor air to meet the ventila- tion requirements of the conditioned space during normal operation. Whenever the indoor fan motor is energized, the dampers open up to one of two pre-selected posi- tions – regardless of the outdoor air enthalpy. Dampers return to the fully closed position when the indoor fan motor is de-energized. Dampers shall fully close on power loss.

ADDITIONAL FACTORY INSTALLED OPTIONS

ALTERNATE INDOOR BLOWER MOTOR – For appli- cations with high restrictions, units are available with optional indoor blower motors that provide higher static output and/or higher airflow.

CONVENIENCE OUTLET (POWERED/NON-POWERED) Unit can be provided with an optional 120VAC GFCI outlet with cover on the corner of the unit housing the compressors.

ELECTRIC HEAT - Electric Heaters range from 9 kW to 54 kW and are available in all the voltage options of the base unit.

PHASE MONITOR - Designed to prevent damage in out- of-phase condition.

COIL GUARD - Designed to prevent condenser coil damage.

BAS CONTROLS - Include supply air sensor, return air sensor, dirty filter indicator and air proving switch.

DIRTY FILTER SWITCH – This kit includes a differential pressure switch that energizes the fault light on the unit thermostat, indicating that there is an abnormally high- pressure drop across the filters.

BREAKER – An HACR breaker can be factory installed on gas heat units or cooling units with electric heat.

DISCONNECT SWITCH - A disconnect can be factory installed on a cooling only units sized for the largest elec- tric heat available.

STAINLESS STEEL HEAT EXCHANGER – For applica- tions in a corrosive environment, this option provides a full stainless steel heat exchanger assembly.

SMOKE DETECTOR – A smoke detector can be factory mounted and wired in the supply and/or return air com- partments.

OTHER PRE-ENGINEERED ACCESSORIES AVAILABLE

ROOF CURB - 14” and 8” high, full perimeter knockdown curb, with hinged design for quick assembly.

BAROMETRIC RELIEF DAMPER – (Unit mounted – Downflow, Duct Mounted – Horizontal) – Contains a rain hood, air inlet screen, exhaust damper and mounting hardware. Used to relieve internal air pressure through the unit during economizer operation.

PROPANE CONVERSION KIT – Contains new orifices and gas valve springs to convert from natural to L.P. gas.

60ºF GAS HEAT KIT – Provides an electric heat kit for the gas compartment for use in extreme low ambient conditions.

ECONOMIZER (Downflow and Horizontal flow)

POWER EXHAUST – (Unit mount – Downflow, Duct mount – Horizontal flow)

DUAL ENTHALPY KIT - Provides a second input to economizer to monitor return air.

Subject to change without notice. Printed in U.S.A.

 

246646-YTG-C-0606

Copyright © 2006 by Unitary Products. All rights reserved.

Supersedes: 246646-YTG-B-1005/036-21059-007-B-1005

 

 

 

Unitary

5005

Norman

Products

York

OK

Group

Drive

73069

Image 48
Contents Technical Guide Ashrae 90.1 CompliantTable of Contents Features All units are shipped with 2 throw-away filters installed Factory Installed Options Field Installed Accessories Low Limit / Compressor Lockout Kit Accessories Part Number Description WeightYTG-C-0606 Ton York Model Number Nomenclature DH Physical Data 078102 DH Capacity Ratings Unit Voltage LimitationsCFM MBH EER IplvCooling Capacity DH078 6-1/2 TON Unit Cooling Capacity DH090 7-1/2 TON Unit Cooling Capacity DH102 8-1/2 TON Unit Cooling Capacity DH120 10 TON Unit Cooling Capacity DH150 12-1/2 TON Unit Return Dry Bulb F4375 5625MCA RLA LRA FLA RLA LRA FLA MCA Electric Heat Multipliers KW Cap. Multiplier240 480DH078 6-1/2 Side Shot Blower Performance DH090 7-1/2 TON Side Shot Blower Performance CFMDH102 8-1/2 TON Side Shot Blower Performance DH120 10 TON Side Shot Blower Performance DH150 12-1/2 TON Side Shot Blower Performance DH078 6-1/2 TON Down Shot Blower Performance DH090 7-1/2 TON Down Shot Blower Performance DH102 8-1/2 TON Down Shot Blower Performance DH120 10 TON Down Shot Blower Performance DH150 12-1/2 TON Down Shot Blower Performance Additional Static Resistance DH120 Additional Static Resistance DH078, 090Indoor Blower Specifications Power Exhaust SpecificationsElectric Heat Minimum Supply AIR CFM Unit Weight Unit Model Number DH078 DH090 DH102 DH120Model Shipping Operating Detail a Detail CUnit Clearances DH078 DH090 DH102 DH120Predator Roof Curb Dimensions Rear Duct Dimensions Bottom Duct Openings from AboveDownflow Economizer Hood Detail Economizer Usage Factory Installed Downflow Economizer Field Installed Horizontal Economizer W/POWER Exhaust Slab Economizer END Return W/POWER Exhaust Cooling Unit with GAS Heat Wiring 230 Volt Diagram Cooling Unit WITH/WITHOUT Electric Heat Wiring Diagram YTG-C-0606 Predator GeneralDescription Unit Operating Characteristics GAS Heating Section if EquippedElectric Heating Section if Equipped Additional Factory Installed Options Other PRE-ENGINEERED Accessories Available

102, 90, DH 078 specifications

York DH series chillers, specifically models 078, 90, and 102, are recognized in the HVAC industry for their advanced features, efficiency, and reliability. These chillers are designed to provide exceptional cooling performance for commercial and industrial applications, prioritizing energy efficiency and sustainability.

One of the standout features of the York DH series is its dual-compressor system. This design not only enhances reliability but also contributes to energy savings by allowing the unit to operate at varying loads more effectively. This adaptability ensures that the chillers can maintain optimal performance even during fluctuating demand, reducing energy consumption and associated costs.

The DH series chillers employ a microchannel condenser technology that maximizes heat exchange efficiency. This technology reduces the amount of refrigerant required while also minimizing the footprint of the unit, offering significant advantages in space-constrained environments. Additionally, microchannel coils are less susceptible to corrosion, enhancing the longevity and reliability of the chillers.

Another notable feature is the use of variable-speed drives (VSD) in the compressor system. These drives allow for precise control of the compressor speed, enabling the chillers to adjust to the cooling demands dynamically. This flexibility not only enhances the overall efficiency of the system but also contributes to quieter operation, making the chillers suitable for environments where noise levels are a concern.

York's DH series also integrates advanced controls and monitoring capabilities. The intuitive control system allows for easy programming and operation, providing users with real-time data on system performance and diagnostics. This feature aids in maintenance and troubleshooting, reducing downtime and ensuring that the chillers operate at peak efficiency.

Safety is paramount in the design of the York DH chillers. Each model is equipped with multiple safety features, including pressure relief valves and temperature monitoring systems, to protect the unit during operation. This commitment to safety not only safeguards the equipment but also ensures compliance with industry standards.

In conclusion, the York DH 078, 90, and 102 chillers exemplify modern HVAC technology with their dual-compressor systems, microchannel condenser technology, variable-speed drives, and advanced control systems. These features combine to deliver efficient, reliable, and sustainable cooling solutions for a wide variety of applications. The York DH series represents a significant advancement in chiller design and functionality, making it a preferred choice for many professionals in the field.