York DH 078, 90, 102 manual All units are shipped with 2 throw-away filters installed

Page 4

Environmentally Aware – For improved Indoor Air Quality, foil faced insulation is used exclusively through- out the units.

Balanced Heating – The Predator® offers “Ultimate Heat- ing Comfort” with a balance between 1st and 2nd stage gas heating. The first stage of a gas heat Predator® unit provides 60% of the heating capacity. Balanced heating allows the unit to better maintain desired temperatures.

Convertible Airflow Design – The side duct openings are covered when they leave the factory. If a side supply/ return is desired, the installer simply removes the two side duct covers from the outside of the unit and installs them over the down shot openings. No panel cutting is required. Convertible airflow design allows maximum field flexibility and minimum inventory.

System Protection - Suction line freezestats are supplied on all units to protect against loss of charge and coil frost- ing when the economizer operates at low outdoor air tem- peratures while the compressors are running. Every unit has solid-core liquid line filter-driers and high and low- pressure switches. Internal compressor protection is stan- dard on all compressors. Crankcase heaters are standard on reciprocating compressors. Scroll compressors do not require crankcase heaters. Phase Monitors are standard on units with scroll compressors. This accessory monitors the incoming power to the unit and protects the unit from phase loss and reversed phase rotation.

Advanced Controls - Simplicity™ control boards have standardized a number of features previously available only as options or by utilizing additional controls.

Low Ambient - An integrated low-ambient control allows all units to operate in the cooling mode down to 0°F outdoor ambient without additional assistance. Optionally, the control board can be programmed to lockout the compressors when the outdoor air tem- perature is low or when free cooling is available.

Anti-Short Cycle Protection - To aid compressor life, an anti-short cycle delay is incorporated into the standard controls. Compressor reliability is further ensured by programmable minimum run times. For testing, the anti-short cycle delay can be temporarily overridden with the push of a button.

Fan Delays - Fan on and fan off delays are fully pro- grammable. Furthermore, the heating and cooling fan delay times are independent of one another. All units are programmed with default values based upon their configuration of cooling and heat.

Safety Monitoring - The control board monitors the high and low-pressure switches, the freezestats, the gas valve, if applicable, and the temperature limit switch on gas and electric heat units. The unit con- trol board will alarm on ignition failures, compressor lockouts and repeated limit switch trips.

Nuisance Trip Protection and Strikes - To prevent nuisance trouble calls, the control board uses a “three times, you’re out” philosophy. The high and

246646-YTG-C-0606

low-pressure switches and the freezestats must trip three times within two hours before the unit control board will lock out the associated compressor.

On Board Diagnostics - Each alarm will energize a trouble light on the thermostat, if so equipped, and flash an alarm code on the control board LED. Each high and low-pressure switch alarm as well as each freezestat alarm has its own flash code. The control board saves the five most recent alarms in memory, and these alarms can be reviewed at any time. Alarms and programmed values are retained through the loss of power.

Reliable – From the beginning – All units undergo com- puter automated testing before they leave the factory. Units are tested for refrigerant charge and pressure, unit amperage, and 100% functionality. For the long term – All Predator® units are painted with a long lasting, pow- der paint that stands up over the life of the unit. The paint used has been proven by a 1000 hour salt spray test.

Flexible Placement – All models and configurations share the same cabinet/footprint and thus the same roof curb. You have the flexibility to set one curb and choose the correct tonnage size and heating option after the internal loads have been determined.

To further simplify planning and installation, Predator® cabinets are designed to fit your roof. With the optional roof curb, the unit ductwork is designed to fit around 24” on-center joists or between 48” on-center joists.

The drain pan can be rotated to drain to either the front or the rear of the unit. Additionally, the drain pan can be fitted to drain through the roof curb. As it is sometimes difficult to have a level installation, the drain pan features a generous slope to ensure proper drainage.

Full Perimeter Base Rails – The permanently attached base rails provide a solid foundation for the entire unit and protect the unit during shipment. The rails offer forklift access from 3 sides, and rigging holes are available so that an overhead crane can be used to place the units on a roof.

Easy Installation – Gas and electric utility knockouts are supplied in the unit underside as well as the side of the unit. A clearly identified location is provided to mount a field sup- plied electrical disconnect switch. Utility connections can be made quickly and with a minimum amount of field labor.

All units are shipped with 2” throw-away filters installed.

Wide Range of Indoor Airflows – All indoor fan motors are belt-drive type providing maximum flexibility to han- dle most airflow requirements. For high static applica- tions, factory installed alternate indoor fan motors are available. With the optional indoor fan motor, all units can supply nominal airflow at a minimum of 1.5” ESP.

Warranty - All models include a 1-year limited warranty on the complete unit. Compressors and electric heater elements each carry a 5-year warranty. Aluminized steel and stainless steel tubular heat exchangers carry a 10- year warranty.

4

Unitary Products Group

Image 4 Contents
Technical Guide Ashrae 90.1 CompliantTable of Contents Features All units are shipped with 2 throw-away filters installed Factory Installed Options Field Installed Accessories Low Limit / Compressor Lockout Kit Accessories Part Number Description WeightYTG-C-0606 Ton York Model Number Nomenclature 078 DH Physical Data102 DH Capacity Ratings Unit Voltage LimitationsCFM MBH EER IplvCooling Capacity DH078 6-1/2 TON Unit Cooling Capacity DH090 7-1/2 TON Unit Cooling Capacity DH102 8-1/2 TON Unit Cooling Capacity DH120 10 TON Unit Cooling Capacity DH150 12-1/2 TON Unit Return Dry Bulb F4375 5625MCA RLA LRA FLA RLA LRA FLA MCA Electric Heat Multipliers KW Cap. Multiplier240 480DH078 6-1/2 Side Shot Blower Performance DH090 7-1/2 TON Side Shot Blower Performance CFMDH102 8-1/2 TON Side Shot Blower Performance DH120 10 TON Side Shot Blower Performance DH150 12-1/2 TON Side Shot Blower Performance DH078 6-1/2 TON Down Shot Blower Performance DH090 7-1/2 TON Down Shot Blower Performance DH102 8-1/2 TON Down Shot Blower Performance DH120 10 TON Down Shot Blower Performance DH150 12-1/2 TON Down Shot Blower Performance Additional Static Resistance DH120 Additional Static Resistance DH078, 090Power Exhaust Specifications Indoor Blower SpecificationsElectric Heat Minimum Supply AIR CFM Unit Model Number DH078 DH090 DH102 DH120 Unit WeightModel Shipping Operating Detail a Detail CUnit Clearances DH078 DH090 DH102 DH120Predator Roof Curb Dimensions Rear Duct Dimensions Bottom Duct Openings from AboveDownflow Economizer Hood Detail Economizer Usage Factory Installed Downflow Economizer Field Installed Horizontal Economizer W/POWER Exhaust Slab Economizer END Return W/POWER Exhaust Cooling Unit with GAS Heat Wiring 230 Volt Diagram Cooling Unit WITH/WITHOUT Electric Heat Wiring Diagram YTG-C-0606 General PredatorDescription GAS Heating Section if Equipped Unit Operating CharacteristicsElectric Heating Section if Equipped Additional Factory Installed Options Other PRE-ENGINEERED Accessories Available