York 90, DH 078, 102 manual Downflow Economizer Hood Detail Economizer Usage

Page 39

246646-YTG-C-0606

391/2 or

47 1/2

Outside Air

Intake Hood

58 1/4

88 1/4

35 3/4

Relief Hood for

Power Exhaust or

Barometric Relief

 

 

26

 

25 3/4

 

 

 

 

 

 

 

 

 

 

 

26

 

 

 

 

 

 

 

 

 

 

 

30 1/4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FIGURE 10 -DOWNFLOW ECONOMIZER HOOD DETAIL

 

 

 

 

 

 

 

 

 

 

TABLE 41: ECONOMIZER USAGE

 

 

 

 

 

 

 

 

 

Application

Cabinet Height

 

 

 

Description

Model

 

 

 

 

 

 

 

 

 

 

 

Bottom Return

All

 

Downflow economizer with barometric relief

2EE04705424

 

 

 

 

 

 

 

 

 

 

 

Side Return

All

 

Horizontal economizer without barometric relief

2EE047055241

ERV or End Return

42"

 

 

 

Slab Economizer,

42” tall cabinet

2EE047056242

50"

 

 

 

Slab Economizer,

50” tall cabinet

2EE047052242

 

 

 

 

1Barometric relief must be ordered seperately and installed in duct work.

2Barometric relief or fresh air hood not included. Must be ordered seperately.

Unitary Products Group

39

Image 39
Contents Ashrae 90.1 Compliant Technical GuideTable of Contents Features All units are shipped with 2 throw-away filters installed Factory Installed Options Field Installed Accessories Low Limit / Compressor Lockout Kit Part Number Description Weight AccessoriesYTG-C-0606 Ton York Model Number Nomenclature DH Physical Data 078102 MBH EER Iplv DH Capacity RatingsUnit Voltage Limitations CFMCooling Capacity DH078 6-1/2 TON Unit Cooling Capacity DH090 7-1/2 TON Unit Cooling Capacity DH102 8-1/2 TON Unit Cooling Capacity DH120 10 TON Unit 5625 Cooling Capacity DH150 12-1/2 TON UnitReturn Dry Bulb F 4375MCA RLA LRA FLA RLA LRA FLA MCA 480 Electric Heat MultipliersKW Cap. Multiplier 240DH078 6-1/2 Side Shot Blower Performance CFM DH090 7-1/2 TON Side Shot Blower PerformanceDH102 8-1/2 TON Side Shot Blower Performance DH120 10 TON Side Shot Blower Performance DH150 12-1/2 TON Side Shot Blower Performance DH078 6-1/2 TON Down Shot Blower Performance DH090 7-1/2 TON Down Shot Blower Performance DH102 8-1/2 TON Down Shot Blower Performance DH120 10 TON Down Shot Blower Performance DH150 12-1/2 TON Down Shot Blower Performance Additional Static Resistance DH078, 090 Additional Static Resistance DH120Indoor Blower Specifications Power Exhaust SpecificationsElectric Heat Minimum Supply AIR CFM Unit Weight Unit Model Number DH078 DH090 DH102 DH120Model Shipping Operating DH078 DH090 DH102 DH120 Detail aDetail C Unit ClearancesPredator Roof Curb Dimensions Bottom Duct Openings from Above Rear Duct DimensionsDownflow Economizer Hood Detail Economizer Usage Factory Installed Downflow Economizer Field Installed Horizontal Economizer W/POWER Exhaust Slab Economizer END Return W/POWER Exhaust Cooling Unit with GAS Heat Wiring 230 Volt Diagram Cooling Unit WITH/WITHOUT Electric Heat Wiring Diagram YTG-C-0606 Predator GeneralDescription Unit Operating Characteristics GAS Heating Section if EquippedElectric Heating Section if Equipped Other PRE-ENGINEERED Accessories Available Additional Factory Installed Options

102, 90, DH 078 specifications

York DH series chillers, specifically models 078, 90, and 102, are recognized in the HVAC industry for their advanced features, efficiency, and reliability. These chillers are designed to provide exceptional cooling performance for commercial and industrial applications, prioritizing energy efficiency and sustainability.

One of the standout features of the York DH series is its dual-compressor system. This design not only enhances reliability but also contributes to energy savings by allowing the unit to operate at varying loads more effectively. This adaptability ensures that the chillers can maintain optimal performance even during fluctuating demand, reducing energy consumption and associated costs.

The DH series chillers employ a microchannel condenser technology that maximizes heat exchange efficiency. This technology reduces the amount of refrigerant required while also minimizing the footprint of the unit, offering significant advantages in space-constrained environments. Additionally, microchannel coils are less susceptible to corrosion, enhancing the longevity and reliability of the chillers.

Another notable feature is the use of variable-speed drives (VSD) in the compressor system. These drives allow for precise control of the compressor speed, enabling the chillers to adjust to the cooling demands dynamically. This flexibility not only enhances the overall efficiency of the system but also contributes to quieter operation, making the chillers suitable for environments where noise levels are a concern.

York's DH series also integrates advanced controls and monitoring capabilities. The intuitive control system allows for easy programming and operation, providing users with real-time data on system performance and diagnostics. This feature aids in maintenance and troubleshooting, reducing downtime and ensuring that the chillers operate at peak efficiency.

Safety is paramount in the design of the York DH chillers. Each model is equipped with multiple safety features, including pressure relief valves and temperature monitoring systems, to protect the unit during operation. This commitment to safety not only safeguards the equipment but also ensures compliance with industry standards.

In conclusion, the York DH 078, 90, and 102 chillers exemplify modern HVAC technology with their dual-compressor systems, microchannel condenser technology, variable-speed drives, and advanced control systems. These features combine to deliver efficient, reliable, and sustainable cooling solutions for a wide variety of applications. The York DH series represents a significant advancement in chiller design and functionality, making it a preferred choice for many professionals in the field.