HP FC1142SR, FC1242SR manual Physical specifications, Cpu

Page 11

Physical specifications

Table 3 lists the physical specifications.

Table 3 HBA physical specifications

Component

Specification

 

 

Host bus

Complies with:

 

PCI Express Base Specification 1.0a

 

PCI Express Card Electromechanical Specification 1.0

 

PCI Bus Power Management Interface Specification 1.1

 

 

Fibre Channel

Bus type: fiber optic media

 

Bus transfer rate:

 

FC1142SR single channel—4 Gb/s Fibre Channel increases

 

aggregate throughput rate to 800 MB/s in full-duplex mode

 

FC1242SR DC dual channel—4 Gb/s Fibre Channel

 

increases aggregate throughput rate to 1.6 GB/s in

 

full-duplex mode

 

 

Central processing unit

Single-chip design that includes a RISC processor, Fibre Channel

(CPU)

protocol manager, PCI-e DMA controller, integrated

 

serializer/deserializer (SERDES), and electrical transceivers that

 

can auto negotiate a data rate of 1, 2, or 4 Gb/s.

 

 

Memory

1 MB SRAM, 1 MB flash (SPI), and 2 KB NVRAM (SPI)

 

 

Signal voltage

3.3 V (mode 1), 3.3 V/1.5 V (mode 2)

 

 

Distance

1 Gb/s: 500 meters 50/125 µm fiber, 300 meters 62.5/125

 

µm fiber

 

2 Gb/s: 300 meters 50/125 µm fiber, 150 meters 62.5/125

 

µm fiber

 

4 Gb/s: 150 meters 50/125 µm fiber, 70 meters 62.5/125 µm

 

fiber

 

 

Cable

50/125μm multimode fiber, 62.5/125 μm multimode fiber

 

 

Connectors

LC connectors that support non-OFC, multimode fiber optic

 

cabling using a SFF optical transceiver module

 

 

Form factor

Low-profile PCIe: 16.765 cm × 6.89 cm

 

(6.6 in. × 2.713 in.)

 

 

Bracket

Standard: 1.84 cm × 12.08 cm (.73 in. × 4.76 in.)

 

Low-profile: 1.84 cm × 8.01 cm (.73 in. × 3.15 in.)

 

 

Power consumption

~11.0 watts

 

 

FC1142SR and FC1242SR DC 4Gb PCI Express host bus adapters for Linux and Windows installation guide 11

Image 11
Contents Part number AA-RWEQA-TE First edition December Page Contents Index Figures Related documentation About this guideIntended audience Document conventions Convention Element Document conventions and symbolsHelpful web sites Subscription serviceHP technical support Page HBA features Environmental specifications Performance specificationsCPU Physical specificationsHBA features Installation prerequisites, Installation procedure, Installing the HBAsLED indicators Installation prerequisitesInstallation procedure Installing the Windows drivers Click Software and drivers Installing the driver kit, Using the fibreutils RPM, Installing the Linux driversUninstalling the RPM Installing the driver kitUsing the RPM to install drivers Installing the RPMLoading and unloading the qla2300 driver manually Using the fibreutils RPMChanging driver parameters Installing the Linux drivers Troubleshooting Fibre Channel checklist Troubleshooting checklistsHardware checklist System configuration checklistLinux driver events Using the Event ViewerTroubleshooting Configuring the HBAs Running Fast!UTIL Configuration SettingsAdapter Settings Selectable Boot Settings Advanced Adapter Settings Raw Nvram Data Restore Default SettingsSelect Host Adapter Scan Fibre Channel DevicesFibre Disk Utility Loopback Data TestLaser device Regulatory compliance and safetyBsmi notice International notices and statementsCanadian notice avis Canadien European Union noticeJapanese notice Korean notice Electrostatic discharge SafetyIndex Bsmi