HP QR516B manual Lpfcdd7xx Lpfcdd732 Lpfc740

Page 50

Example 2 (set up as follows):

LSI 2G FC HBA installed on the HP 3PAR StoreServ Storage

12 ESX hosts attached to a LSI port on the HP 3PAR StoreServ Storage Formula:

510 / 12 = 42.xxx (recommended max target port queue depth = 42)

Setting tgt_queue_depth for Emulex in ESX 3.x (example)

To set the tgt_queue_depth for an Emulex FC HBA in ESX 3.x to something other than the default requires a multistep process:

1.Shut down all of the virtual machines.

2.Log into the ESX service console as root.

3.Make a backup copy of /etc/vmware/esx.conf.

cp /etc/vmware/esx.conf /etc/vmware/esx.conf.orig

4.Identify the Emulex HBA module that is currently loaded.

vmkload_mod –l grep –i lpfc

Depending on the module of the HBA, the module can be one of the following:

lpfcdd_7xx

lpfcdd_732

lpfc_740

5.The target queue depth can now be modified via the command line using VMware supplied binaries.

The example shows the lpfc_740 module. Use the appropriate module based on the outcome of Step 4.

esxcfg-module –s “lpfc_tgt_queue_depth=31” lpfc_740 esxcfg-boot –b

6.You can check to see that the change has been implemented as follows:

esxcfg-module -q

7.Reboot the ESX host for the changes to take effect.

Upon bootup, the ESX host will now be throttled to a maximum of 31 outstanding commands (as in the example shown in Step 5) to the target HP 3PAR StoreServ Storage port).

Setting ql2xmaxdepth for QLogic in ESX 3.x (example)

To set the ql2xmaxdepth for an QLogic FC HBA in ESX 3.x to something other than the default requires a multi step process.

1.Shut down all of the virtual machines.

2.Log into the ESX service console as root.

50 Configuring the Host for a Fibre Channel Connection

Image 50
Contents HP 3PAR VMware ESX Implementation Guide Acknowledgments Contents Target Configuring the Host for an iSCSI ConnectionAllocating Storage for Access by the ESX Host Support and Other ResourcesDocumentation feedback Required Supported ConfigurationsIntroduction RequiredHP 3PAR OS Upgrade Considerations Audience# showport -par Configuring the HP 3PAR StoreServ Storage for Fibre ChannelSetting Up the Ports Creating the Host Definition # showhost -listpersona# showhost # showhost -persona# controlport persona 7 nodeslotport Setting Up and Zoning the Fabric # createhost ESXserver1 10000000C9724AB2 10000000C97244FEConfiguration Guidelines for Fabric Vendors HP 3PAR CoexistenceTarget Port Limits and Specifications AdminportcfgfillwordHP 3PAR Priority Optimization Persistent Ports Persistent Ports Setup and Connectivity Guidelines # showportUnsupported Configurations Persistent Ports Limitations# controlport config iscsi # showport Configuring the HP 3PAR StoreServ Storage for iSCSISetting Up the Ports for an iSCSI Connection Software iSCSI Support# controliscsiport ping 10.1.1.10 # showport -iscsi# vmkping ESX1 Setting Up and Configuring Chap Authentication Chap Authentication in ESX Chap Credentials in ESX/ESXi 4.x or ESX/ESXi For ESX 4.x Hardware iSCSI Support # showhost -chapSetting a Static IP Address Showiscsisession Chap Configuration for One-Way Chap Chap Configuration for Mutual Chap Target Port Limits and Specifications HP 3PAR Priority Optimization# showport -i 031 Configuring the HP 3PAR StoreServ Storage for FCoE# controlport config fcoe # showport 031 # showport -fcoeTurn off the iSCSI ports # controlport offline ShowportCreating the Host Definition Target Port Limits and Specifications # esxcli brocade bcu --command=port --list Configuring the Host for a Fibre Channel ConnectionInstalling the HBA and Drivers # esxcli brocade bcu --command=vhba --query 1/0Installing Virtual Machine Guest Operating System Http//kb.vmware.comMultipath Failover Considerations and I/O Load Balancing # cat /etc/rc.localConfiguring the Host for a Fibre Channel Connection Multipath Failover Considerations and I/O Load Balancing LUN Set to Round Robin Vmwpsprr Vmwpspfixed Vmwpspmru ESX/ESXi 4.0 GA 4.0 Ux To remove the above Alua custom Satp ruleESX/ESXi 4.1 GA 4.1 Ux ESXiSatp Info Commands Default Satp Rules and Their Current Default PSP# esxcli nmp satp listrules grep -i 3par Satp Custom Rules and Associated Defined ParametersShow Device Information # esxcli storage nmp device list naa.50002ac0000a0124# esxcli nmp device list naa.50002ac000b40125 # esxcli storage nmp device list -d naa.50002ac0005800ac# esxcli nmp device list -d naa.50002ac0005800ac Performance Considerations for Multiple Host ConfigurationsVMware ESX Releases through ESX 3.5 Update # esxcli storage core device list VMware ESX Release 3.5 Update 4 through ESX 4.x and ESXiVMware ESXi Release Esxcli storage core device list --device devicename497 / 16 = 31.xxx recommended max target port queue depth = Lpfcdd7xx Lpfcdd732 Lpfc740 VStorage APIs for Array Integration Vaai ESX/ESXi 4.1, ESXi 5.x Additional Feature ConsiderationsStorage I/O Control HP 3PAR Vaai Plugin 1.1.1 for ESXi HP 3PAR Vaai Plugin 2.2.0 for ESXiOut-of-Space Condition for ESX 4.1 and ESXi # cd /vmfs/volumes/volune-nameUnmap Space Reclaim Storage Hardware Support for ESXi # mount -t ext4 -o discard /dev/sda2 /mnt# showalert Vaai and New Feature Support Table Additional New Primitives Support on ESXi# esxcfg-scsidevs -l naa.50002ac0002200d7 Vaai Plugin Verification# esxcli storage core plugin list Vaai Status supported# esxcfg-scsidevs -l naa.50002ac003da00eb # esxcli storage core plugin list Plugin name Plugin classVMware All Paths Down Hardware Acceleration for HP 3PAR devicesConfiguring the FCoE Switch Using system Bios to configure FCoEConfiguring FCoE Configuring the PCI Slots Configuring Initiator FCoE to FC Target Exiting the Bios UtilityConfiguring Initiator FCoE to Target FCoE Initiator FCoE to FC TargetInitiator FCoE to Target FCoE Configuring the Host for an iSCSI Connection Installing iSCSI on VMware ESXConfiguring the Host for an iSCSI Connection Creating a VMkernel Port Configuring the Host for an iSCSI Connection Click OK to complete Click Next Configuring the Host for an iSCSI Connection Page Configuring the VMware iSCSI Initiator Configuring the VMware iSCSI Initiator Configuring the Host for an iSCSI Connection Configuring the VMware iSCSI Initiator # showhost ESX/ESXi Additional Feature Considerations Using the HP 3PAR Management Console Allocating Storage for Access by the ESX HostCreating Virtual Volumes for HP 3PAR OS 2.2.4 and Later Using the HP 3PAR OS CLI# createaldvv options vvname.index sizegGtT Creating Virtual Volumes for HP 3PAR OS 2.2.3 or EarlierExporting LUNs to an ESX Host # createaldvv -cnt 5 TESTLUNs 5G# createvlun options VVname VVset LUN hostname/set Creating a Vlun for Export# createvlun options VVname VVset LUN nodeslotport # createvlun options VVname VVset LUN nodeslotport/hostnameRemoving Volumes Discovering LUNs on VMware ESX HostsHost and Storage Usage Eventlog and Host Log MessagesHost and Storage Usage Page HP 3PAR documentation Support and Other ResourcesContacting HP Reference Storage Physical Planning Typographic conventions HP 3PAR branding informationDocumentation feedback