HP Cassette Player DDS-3 manual ±2. Setting the Write-Protect Tab on a DDS Tape

Page 31

Using Your DDS Drive

Push￿ tab￿ right for￿￿￿￿￿￿.

Push￿ tab￿ left￿ for

￿￿￿￿￿￿￿￿￿￿￿￿￿.

Figure 2±2. Setting the Write-Protect Tab on a DDS Tape

To protect information on a data cassette from being overwritten, set the write-protect tab to the write-protectposition, as shown in Figure 2±2.

NOTICE: The write-protect tab should always be in the write position for transferring data to a cassette.

2±5

Image 31
Contents HP DDS-3 Tape Drive Users Guide 10 9 8 7 6 5 4 3 2 Contents Troubleshooting and Removal/Replacement Procedures Using the DDS-DC DriveAppendix a Scsi Connector Pinouts Tables FiguresAudience PrefaceFederal Communications Commission FCC Safety and Regulatory StatementsCanadian Department of Communications CDC Emissions Regulations Compliance Electrostatic Discharge ESD PrecautionsRelated Manuals Installation NoticeDocumentation Conventions Questions, Suggestions, or ProblemsLiteral values Chapter ±1. HP DDS-3 Drive General DescriptionVibration Ambient TemperatureDDS-3 Drive Environmental Requirements HumiditySuspended Particles ShockAltitude Transportation±2 describes the physical specifications of the DDS-3 drive DDS-3 Drive Physical SpecificationsOperating System Support Preparing to Install a New DDS-3 DriveVerifying Kit Contents Tools RequiredSetting the SCSI-2 Address Address Jumpers PWR ±4. Switch Settings for Data Compression Operation Mode Usr/sbin/ioscan Return Preparing the System# /etc/shutdown -h Return SCSI-2 Connection and TerminationPowering Off the Workstation and Any Peripherals ±5. Adding a Bezel to the DDS-3 Drive ±6. Removing a Bezel from the DDS-3 Drive ±7. Adding or Removing Expansion Brackets Using the DDS-3 Drive Controls and Features of the DDS-3 Drive Your DDS-3 Drive ConfigurationData Cassettes LEDsCleaning the Tape Heads ±2. Setting the Write-Protect Tab on a DDS Tape Loading and Unloading a Data Cassette Using the DDS-3 DriveMedia Interchangeability Restrictions Verifying the DDS-3 Tape Drive OperationUsr/sbin/ioscan -d stape Return DDS-DC DDS-2 DDS-3 Tape Length Full Height 5 1/4Ordering Information Troubleshooting and Removal/Replacement Procedures Checking the Address Settings for Single-Ended Drives TroubleshootingChecking the Hardware Installation # /etc/shutdown -h Return Man cstm Return Man mstm Return Man xstm Return Rechecking the Address SettingsFollowing screen appears Messages similar to the following appear Cstm verify all ReturnDescription Removal/Replacement ProceduresPowering Off the System Field Replaceable UnitsRemoving and Replacing the DDS-3 Drive ±1. Adding a Bezel to the DDS-3 Drive ±3. Adding or Removing Expansion Brackets Appendix a Index Index-2 HP DDS-3 Tape Drive Users Guide Order Number A1658±90702 Edition