HP B.06.X manual Return Values, Options

Page 74

PPU Manpages

ppuconfig (1M) Manpage

Options

ppuconfig recognizes the following command-line options and arguments:

-mmeter Specifies the utility meter that the Pay Per Use system should use for reporting. The meter can be specified as a fully qualified hostname or IP address. A non-blank value is required.

-pproxy[:port] Specifies the proxy server that should be used by this system for HTTPS transmission if a proxy server is required. Optionally, a port number can be appended to the proxy server specification. Proxy configuration can be cleared by specifying an empty string (“”) as the proxy server value.

-ssystem_id

Specifies the system identifier that the Pay Per Use

 

system should use when reporting. This can be any

 

value that helps you to identify this system (for

 

example, a tracking number, asset number, physical

 

location, etc). Until a system identifier is specified, the

 

hostname will be used by default.

-h

Specifies that the hostname should be used as the

 

system identifier for the Pay Per Use system, when

 

reporting usage information.

-u

Starts an interactive session to allow setting a

 

username and password for the proxy server, if

 

required by the proxy server. These values can be

 

cleared by pressing Enter when prompted for a

 

username.

-t

Perform communication test between Pay Per Use

 

software and the configured utility meter.

RETURN VALUES

ppuconfig exits with one of these values:

0Success.

>0

Failure; error message sent to STDERR

74

Appendix D

Image 74
Contents Pay Per Use PPU User’s Guide for Versions B.06.x Fifth EditionCopyright Notices WarrantyRestricted Rights Legend Trademark Notices Publication History Docs.hp.comUser input Ls -a -iPage Contents Using the PPU Software About this guide Welcome How to Use this GuideIntroduction HP On Demand Solutions Program ICODOverview System OverviewHttps Client Utility Meter Usage Database PPU Supported Hardware Platforms Most Recent PPU Version and Supported PlatformsHttp//software.hp.com Locating the PPU User’s Guide for versions B.06.x PPU InformationPPU User’s Guide History ManpagesPPU Information Chapter Understanding PPU RequirementsPPU Program Requirements For PPU Versions B.06.x on HP-UX 11i PPU Software RequirementsHP-UX 11i v2 Requirements HP-UX 11i v1 Requirements Required Patches for PPU on HP-UX 11iPPU System Move Requirements PPU System Move Requirements Chapter Installing and Configuring PPU SoftwareUsr/sbin/ppuconfig -t Getting StartedStep Usr/bin/ps -e grep ppudFor HP-UX 11i v1 or 11i v2 Installing from the OE Installing PPU SoftwareHow To Find The Latest Patches MediaMount -r /dev/dsk/c1t2d0 /cdrom For HP-UX 11i v1 or 11i v2 Installing from the ARSwinstall -s /cdrom T2351AA Software Depot For HP-UX 11i v1 or 11i v2 Installing from the HPSwinstall -s \ Var/tmp/T2351AAB.06.04 HP-UXB.11.2332+64.depot ’*’Usr/sbin/ppuconfig -m meter Configuring PPU SoftwareConfiguring the Utility Meter required Usr/sbin/ppuconfig -p proxyport Configuring the Proxy Server if necessaryConfiguring the System Identifier if desired Usr/sbin/ppuconfig -uVerifying the https Connection Viewing the System SettingsUsr/sbin/ppuconfig Manually Starting the ppud Daemon Sbin/init.d/ppu startRe-installing PPU Software Usr/sbin/swlist grep T2351AA Un-installing PPU SoftwareUsr/sbin/swremove -x enforcescripts=false T2351AA Using the PPU Software PPU Web Portal PPU Usage Report Example 4-1 PPU 6.x Usage ReportCPUID5/CPUID PPU Usage Report PercentCPUUsage63.000/PercentCPUUsage UsageEntry -UsageEntry CPUID4/CPUID Administration for nPartitions for details Understanding Utilization CappingNew Partition Creation New Partition Creation Chapter Troubleshooting Troubleshooting the PPU Software Usr/sbin/swverify T2351AAPPU Executable and Configuration Files Troubleshooting the PPU Software Chapter Frequently Asked Questions Is pay per use the same as leasing? What is pay per use?Pay Per Use Program Pay Per Use Software What software product is required for PPU systems?When is information sent by the PPU software? How many usage reports are retained on the PPU system?Open Source and Licenses Open Source Components Curl Mitx License PPU software is released under the following licenseOpenSSL License Following license applies to OpenSSL with libcryptoOpenSSL License OpenSSL License Special Considerations Export Issues Reboot -R -H Shutdown -R -H Inactive Partitions in PPU SystemsInactive Partitions in PPU Systems Verifying PPU Utilization Information Usr/bin/nice --10 /usr/sbin/sar -o /tmp/sarOut 300Usr/sbin/sar -uM /tmp/sarOut /tmp/sarOut.report Glossary Configured processors PPU TerminologyPay per use PPU Terminology Appendix C PPU Manpages Ppu 5 Manpage DescriptionPpud 1M Manpage Ppuconfig 1M, ppu Ppuconfig 1M Manpage Return Values OptionsFiles Ppuconfig 1M Manpage Appendix D Index Index