HP AUTOMATIC XT SPAY GUNS 311051D manual Install Air Fittings, Ground System

Page 11

Install Air Fittings

1.Install the supplied 1/4 in. tube fitting into the cylin- der (CYL) air port.

2.Install 3/8 in. tube fittings into the atomization (ATOM) air port and the fan (FAN) air port.

CYL

ATOM

FAN

TI8211a

 

FIG. 4: Air Fittings

Ground System

The following grounding instructions are minimum requirements for a system. Your system may include other equipment or objects that must be grounded. Check your local electrical code for detailed grounding instructions for your area and type of equipment. Your system must be connected to a true earth ground.

Ground Pump/Fluid Supply

Ground the pump by connecting a ground wire and clamp between the fluid supply and a true earth ground as instructed in your separate pump instruction manual.

Ground Air Compressors and Hydraulic Power Supplies

Ground the air compressors and hydraulic power sup- plies according to the manufacturer recommendations.

Ground Spray Gun

Ground the spray gun by mounting the manifold to a properly grounded reciprocator, robot, or stationary mount. Check the electrical resistance between the manifold and a true earth ground. The resistance must be less than 1 megohm.

Installation

Ground Fluid Supply Container

Ground the fluid supply container according to local code.

Ground Object Being Sprayed

Ground the object that is being sprayed according to local code.

Ground Solvent Pails

Ground all solvent pails that are used when flushing according to local code. Use only metal pails, which are conductive. Do not place the pail on a non-conductive surface, such as paper or cardboard, which interrupts the grounding continuity.

311051D

11

Image 11
Contents Automatic XT Spray Guns Related Manuals ContentsCompliant Airspray ModelsOrifice Size In. mm Equipment Misuse Hazard Toxic Fluid or Fumes Hazard Hvlp Spray Gun Assemblies Selection ChartsAirspray Gun Assemblies Compliant Spray Gun Assemblies Air Caps Proper Needle/Nozzle Selection Gun Selection Hvlp Gun Air Cap Pressure Air FlowNon-circulating System InstallationVentilate Spray Booth Configure Gun and ManifoldGround System Install Air FittingsStationary Support Mount GunReciprocating Arm Rod Mount Retrofit Adapter PlateConnect Fluid Hose SetupConnect Air Line Position Air Cap Flush Spray GunCompliant Hvlp and Compliant Gun Limits Adjust Spray PatternAir Pressure Regulator Incorrect Pressure Relief ProcedureOperation Apply FluidDaily Gun Care Perform Pressure Relief Procedure, General System MaintenanceClean and Flush Gun Problem Cause Solution TroubleshootingGeneral Troubleshooting Troubleshooting Spray Pattern Troubleshooting Replace Fluid Packings and Air Seals ServiceItems Needed for Service Alternate Fluid Control Shown Reassembly Exploded View Part No Gun Shown PartsOrifice Size Large PartsAir Caps Part No. Description QtySpray Gun Assemblies all models Manifold with Bottom Fluid Ports Manifold with Side Fluid Ports Description QtySide Fluid Ports and Fan Adjustment Valve RING, Ptfe Accessories Dimensions Manifold Mounting Hole Layout Mounting Hole LayoutRetrofit Adapter Plate Gun with Retrofit Rear Port ManifoldTriggering Speed Technical DataGraco Information Graco Standard Warranty