HP AUTOMATIC XT SPAY GUNS 311051D manual Technical Data, Triggering Speed

Page 37

Technical Data

Technical Data

Maximum Working Fluid Pressure

100 psi (0.7

MPa, 7 bar)

Maximum Working Air Pressure

100 psi (0.7

MPa, 7 bar)

Maximum HVLP Inbound Air Pressure

35 psi (25 kPa, 2.5 bar)

Maximum Compliant Gun Inlet Pressure

30 psi (21 kPa, 2.1 bar)

Maximum Working Fluid Temperature

120° F (49° C)

Minimum Air Cylinder Actuation Pressure

50 psi (0.34

MPa, 3.4 bar)

Weight

1.5 lbs (992 g)

Wetted Parts

Stainless Steel, Ultra High Molecular Weight Polyethyl-

 

ene, Chemically Resistant Fluoroelastomer, Acetal,

 

PTFE, PEEK

Loctite® is a registered trademark of the Loctite Corporation.

Triggering Speed

These values apply to a new gun with a 12 ft. (3.6 m), 1/4 in. (6.3 mm) OD cylinder air line and a 0.055 in. nozzle. These values will vary slightly with use and with variations in equipment.

Cylinder Air Pressure

Fluid Pressure

Air Pressure

 

 

psi (kPa, bar)

psi (kPa, bar)

psi (kPa, bar)

msec to fully open

msec to fully close

 

 

 

 

 

50 (0.35, 3.5)

50 (0.35, 3.5)

100 (0.7, 7.0)

58.4

50.4

 

 

 

 

 

Sound Data (dBa)

 

 

Atomizing Air

 

 

 

Air Cap

Nozzle Part No.

Pressure

Fan Air Pressure

Sound Pressure

Sound Power

Part No.

and Size

psi (kPa, bar)

psi (kPa, bar

dB(A)†

dB(A)‡

 

 

 

 

 

 

288134

234744, 0.055 in.

35 (250, 2.5)

35 (250, 2.5)

85.9

86.7

100 (0.7, 7.0)

100 (0.7, 7.0)

97

92.8

 

 

 

 

 

 

 

 

Sound pressure measured 3.28 ft. (1 m) from equipment.

‡ Sound power measured per ISO 9614-2.

311051D

37

Image 37
Contents Automatic XT Spray Guns Related Manuals ContentsOrifice Size In. mm ModelsCompliant Airspray Equipment Misuse Hazard Toxic Fluid or Fumes Hazard Hvlp Spray Gun Assemblies Selection ChartsAirspray Gun Assemblies Compliant Spray Gun AssembliesGun Selection Proper Needle/Nozzle SelectionAir Caps Hvlp Gun Air Cap Pressure Air FlowVentilate Spray Booth InstallationConfigure Gun and Manifold Non-circulating SystemGround System Install Air FittingsReciprocating Arm Rod Mount Mount GunRetrofit Adapter Plate Stationary SupportConnect Air Line SetupConnect Fluid Hose Position Air Cap Flush Spray GunCompliant Hvlp and Compliant Gun Limits Adjust Spray PatternAir Pressure Regulator Operation Pressure Relief ProcedureApply Fluid IncorrectDaily Gun Care Clean and Flush Gun General System MaintenancePerform Pressure Relief Procedure, General Troubleshooting TroubleshootingProblem Cause Solution Troubleshooting Spray Pattern Troubleshooting Items Needed for Service ServiceReplace Fluid Packings and Air Seals Alternate Fluid Control Shown Reassembly Exploded View Part No Gun Shown PartsAir Caps PartsPart No. Description Qty Orifice Size LargeSpray Gun Assemblies all models Manifold with Bottom Fluid Ports Manifold with Side Fluid Ports Description QtySide Fluid Ports and Fan Adjustment Valve RING, Ptfe Accessories Dimensions Manifold Mounting Hole Layout Mounting Hole LayoutRetrofit Adapter Plate Gun with Retrofit Rear Port ManifoldTriggering Speed Technical DataGraco Information Graco Standard Warranty