HP AUTOMATIC XT SPAY GUNS 311051D manual Air Pressure Regulator

Page 16

Setup

F

FIG. 13: Air Pressure Regulator

TI01997

3.Test the spray pattern atomization while keeping the gun a consistent distance, about 6 to 8 inches (150 to 200 mm), from the test piece.

Check the atomization quality. Increase the gun atomizing air supply pressure with the air pressure regulator in 5 psi (34 kPa, 0.3 bar) increments until you obtain the desired atomization.

For the best transfer efficiency, use the lowest set- ting needed to achieve desired finish quality.

4.If the spray pattern is too wide or split, reduce the fan air pressure (or slightly close the fan adjustment valve on manifold 288223).

To further control the spray pattern of airspray guns only, use an alternate air cap. For a list of available air caps, refer to Accessories, page 33.

Reducing the fan air pressure to 0 psi (or fully clos- ing the fan adjustment valve) will produce a round pattern.

16

311051D

Image 16
Contents Automatic XT Spray Guns Contents Related ManualsOrifice Size In. mm ModelsCompliant Airspray Equipment Misuse Hazard Toxic Fluid or Fumes Hazard Selection Charts Hvlp Spray Gun AssembliesCompliant Spray Gun Assemblies Airspray Gun AssembliesGun Selection Proper Needle/Nozzle SelectionAir Caps Air Flow Hvlp Gun Air Cap PressureInstallation Ventilate Spray BoothConfigure Gun and Manifold Non-circulating SystemInstall Air Fittings Ground SystemMount Gun Reciprocating Arm Rod MountRetrofit Adapter Plate Stationary SupportConnect Air Line SetupConnect Fluid Hose Flush Spray Gun Position Air CapAdjust Spray Pattern Compliant Hvlp and Compliant Gun LimitsAir Pressure Regulator Pressure Relief Procedure OperationApply Fluid IncorrectDaily Gun Care Clean and Flush Gun General System MaintenancePerform Pressure Relief Procedure, General Troubleshooting TroubleshootingProblem Cause Solution Troubleshooting Spray Pattern Troubleshooting Items Needed for Service ServiceReplace Fluid Packings and Air Seals Alternate Fluid Control Shown Reassembly Parts Exploded View Part No Gun ShownParts Air CapsPart No. Description Qty Orifice Size LargeSpray Gun Assemblies all models Manifold with Bottom Fluid Ports Description Qty Manifold with Side Fluid PortsSide Fluid Ports and Fan Adjustment Valve RING, Ptfe Accessories Dimensions Mounting Hole Layout Manifold Mounting Hole LayoutRear Port Manifold Retrofit Adapter Plate Gun with RetrofitTechnical Data Triggering SpeedGraco Standard Warranty Graco Information