York D1EG, D1EE036 warranty DEE Supply Model Stages SIZE1 Motor Ampacity, Amps Breaker FLA

Page 19

036-21411-002-A-0204

TABLE 20: ELECTRICAL DATA COOLING/ELECTRIC HEAT W/ DIRECT DRIVE DEE060

 

 

HEATER

 

SUPPLY

 

ELECTRIC HEATERS

 

MAX.

MAX.

MODEL

POWER

ACCESSORY

 

AIR

 

 

 

 

MINIMUM

FUSE

SIZE

2

 

BLOWER

 

 

 

TOTAL

CIRCUIT

HACR

DEE

SUPPLY

MODEL

 

kW

 

STAGES

SIZE1

 

MOTOR

 

AMPACITY

 

 

 

NUMBER

 

 

 

 

AMPS

AMPS

BREAKER

 

 

 

FLA

 

 

 

 

 

AMPS

 

 

 

 

 

 

 

 

 

 

 

 

2CE04500506

 

 

4.0

 

1

19.1

49.0

80

80

 

 

 

2CE04500706

 

 

5.6

 

1

27.1

49.0

80

80

 

 

208-1-60

2CE04501006

 

8.6

8.0

 

1

38.3

56.1

80

80

 

 

 

 

 

 

 

 

 

 

 

 

 

2CE04501506

 

11.9

 

2

57.4

80.0

90

90

 

 

 

 

 

 

 

 

 

2CE04502006

 

 

15.9

 

2

76.6

103.9

110

110

 

 

 

2CE04503006

 

 

22.2

 

2

106.9

141.9

150

150

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2CE04500506

 

 

5.3

 

1

22.1

49.0

80

80

 

 

 

2CE04500706

 

 

7.5

 

1

31.3

49.0

80

80

 

 

230-1-60

2CE04501006

 

8.6

10.6

 

1

44.2

63.5

80

80

 

 

 

 

 

 

 

 

 

 

 

 

 

2CE04501506

 

15.9

 

2

66.3

91.1

100

100

 

 

 

 

 

 

 

 

 

2CE04502006

 

 

21.2

 

2

88.3

118.7

125

125

 

 

 

2CE04503006

 

 

29.6

 

2

123.3

162.4

175

175

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2CE045005253

 

 

4.0

 

1

11.0

33.0

50

50

 

 

 

2CE045007253

 

 

5.6

 

1

15.6

33.0

50

50

 

 

208-3-60

2CE04501025

6.0

8.0

 

1

22.1

35.9

50

50

 

 

 

 

 

 

 

 

 

 

 

 

 

2CE04501525

 

 

11.9

 

2

33.1

49.7

50

50

 

060

 

2CE04502025

 

 

15.9

 

2

44.2

63.5

70

70

 

 

2CE04503025

 

 

22.2

 

2

61.7

85.4

90

90

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2CE045005253

 

 

5.3

 

1

12.7

33.0

50

50

 

 

 

2CE045007253

 

 

7.5

 

1

18.0

33.0

50

50

 

 

230-3-60

2CE04501025

6.0

10.6

 

1

25.5

40.1

50

50

 

 

 

 

 

 

 

 

 

 

 

 

 

2CE04501525

 

 

15.9

 

2

38.2

56.1

60

60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2CE04502025

 

 

21.2

 

2

51.0

72.0

80

80

 

 

 

2CE04503025

 

 

29.6

 

2

71.2

97.3

100

100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2CE045007463

 

 

6.8

 

1

8.2

17.2

25

25

 

 

 

2CE045010463

 

 

10.1

 

1

12.1

19.3

25

25

 

 

460-3-60

2CE045015463

3.0

13.6

 

1

16.4

24.6

25

25

 

 

 

2CE045020463

 

 

19.5

 

2

23.5

33.4

35

35

 

 

 

2CE045030463

 

 

28.8

 

2

34.6

47.4

50

50

 

 

 

2CE04501058

 

 

10.6

 

1

10.2

16.9

20

20

 

 

575-3-60

2CE04501558

 

2.4

15.9

 

1

15.3

23.2

25

25

 

 

2CE04502058

 

21.2

 

2

20.4

29.6

30

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2CE04503058

 

 

30.4

 

2

29.3

40.7

45

45

 

1.Dual element, time delay type.

2.Standard circuit breakers may be used in Canada and on applications over 60 amps where the heaters are separately fused.

3.These electric heaters DO NOT include a fuse box. If a fuse box is required to meet a local code (e.g. Chicago), the following fuse block accessories are available for field installation (see Table 19).

Unitary Products Group

19

Image 19
Contents Featuring Flexible Easy to Install Single Package UnitsTechnical Guide Sunline Plus AIR-COOLED AIR Conditioners GeneralTable of Contents Description FeaturesFIELD-INSTALLED Accessories FACTORY-INSTALLED OptionsSunline Plus Component Location Capacity Ratings Cooling / Electric Heating Sound Power RATINGS1Capacity Ratings Cooling / GAS Heating Models DEE/DEG Physical Data Basic UnitEvaporator Sensible CAPACITY1, MBH AIR on Temperature of AIR on Condenser CoilTotal Power Cooling Capacities 3 TON DEE / DEG036Cooling Capacities 4 TON DEE / DEG048 Cooling Capacities 5 TON DEE / DEG060 Flow CFM RPM Watts Model AIR Available External Static Pressure IWG3036-21411-002-A-0204 2500 1059 1560 1077 1590 1095 1630 RESISTANCE, IWG Description CFM Static ResistancesMED LOWBelt MOTOR1 AdjustableMotor and Drive Data BELT-DRIVE Blower Basic Unit W/ DIRECT-DRIVE Electrical DataBasic Unit W/ BELT-DRIVE Electrical Data Electrical Data COOLING/ELECTRIC Heat W/ Direct Drive DEE036 Part Number Volts Fuse Block AccessoryElectric Heat Correction Factors Nominal VoltageAmps Breaker FLA DEE Supply Model Stages SIZE1 Motor AmpacityElectrical Data COOLING/ELECTRIC Heat W/ Belt Drive DEE036 DEE Supply Model Stages Electrical Data COOLING/ELECTRIC Heat W/ Belt Drive DEE060Motor Ampacity Comprssorr Elayand COOLING/HEATINGELECTRONICTHERMOSTAT Singlestage Size DIA Hole KnockoutUnit Dimensions DEG 3, 4, & 5 TON DEE/DEG Unit Clearances DEE/DEG Dimensions Rear View 3, 4, & 5 TON Detail B Unit Dimensions with DAMPER/RAINHOOD Unit Corner Weights Roof Curb Dimensions DEE & DEG 3, 4, & 5 TON Unit WeightsTypical Applications Mechanical Specifications Electrical Requirements Unit Operating CharacteristicsGAS Heating Section DEG Models Electric Heating Section DEE ModelsOther Factory Installed Options Other PRE-ENGINEERED Accessories AVAIL- AbleOptional Outdoor AIR

D1EG, D1EE036 specifications

The York D1EE036 and D1EG are two models of high-performance direct expansion (DX) rooftop air conditioning units designed for commercial applications. These units are known for their efficiency, reliability, and advanced technology.

The D1EE036 model is particularly recognized for its energy efficiency, featuring a high-efficiency scroll compressor. This compressor operates at lower energy consumption levels while providing consistent cooling performance. The unit is equipped with variable speed technology, which adjusts the compressor's speed according to the cooling demand. This feature not only optimizes energy use but also minimizes the sound levels during operation, making it suitable for noise-sensitive environments such as hospitals and schools.

On the other hand, the D1EG model is designed for versatility and offers a range of custom configuration options. It incorporates advanced controls that allow for integration with building management systems, enabling users to monitor and manage their HVAC systems remotely. The D1EG is also notable for its robust construction, with weather-resistant enclosures that ensure durability and longevity in various environmental conditions.

Both models feature an advanced microprocessor control system that provides precise temperature control and enhances overall system efficiency. These controls allow for multiple unit configurations, including staged cooling, which further contributes to energy savings. Additionally, both units come equipped with high-efficiency filters that improve indoor air quality by trapping dust, pollen, and other airborne particles.

From a technological standpoint, the York D1EE036 and D1EG models support environmentally friendly refrigerants, which comply with the latest regulations for reducing ozone depletion potential. The use of these refrigerants not only helps in meeting regulatory requirements but also aligns with global sustainability goals.

In summary, the York D1EE036 and D1EG rooftop units are engineered to deliver excellent performance, adaptability, and energy efficiency for commercial settings. Their combination of innovative technologies, environmentally conscious design, and advanced control features make them a compelling choice for businesses looking to enhance their HVAC systems while reducing operational costs. Whether requiring quiet operation or robust configurability, these units offer solutions that cater to diverse commercial needs.