York D1EE036, D1EG warranty Electric Heat Correction Factors, Fuse Block Accessory, Nominal Voltage

Page 18

036-21411-002-A-0204

TABLE 17: ELECTRICAL DATA COOLING/ELECTRIC HEAT W/ DIRECT DRIVE DEE048

 

 

 

HEATER

SUPPLY

 

ELECTRIC HEATERS

 

 

 

MAX

MAX.

 

 

 

AIR

 

 

 

 

 

 

MINIMUM

MODEL

POWER

ACCESSORY

 

 

 

 

 

 

FUSE

BLOWER

 

 

 

 

TOTAL

 

CIRCUIT

SIZE

DEE

SUPPLY

MODEL

kW

 

STAGES

 

 

SIZE

1

MOTOR

 

 

AMPS

 

AMPACITY

 

HACR2

 

 

 

NUMBER

 

 

 

 

 

 

 

FLA

 

 

 

 

 

 

 

AMPS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2CE04500506

 

4.0

 

1

 

19.1

38.6

60

 

60

 

 

 

2CE04500706

 

5.6

 

1

 

27.1

39.9

60

 

60

 

 

208-1-60

2CE04501006

5.0

8.0

 

1

 

38.3

54.3

60

 

60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2CE04501506

 

11.9

 

2

 

57.4

77.8

80

 

80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2CE04502006

 

15.9

 

2

 

76.6

101.8

110

 

110

 

 

 

2CE04500506

 

5.3

 

1

 

22.1

38.6

60

 

60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2CE04500706

 

7.5

 

1

 

31.3

45.3

60

 

60

 

 

230-1-60

 

5.0

 

 

 

 

 

 

 

 

 

 

 

2CE04501006

10.6

 

1

 

44.2

61.5

70

 

70

 

 

 

2CE04501506

 

15.9

 

2

 

66.3

89.1

90

 

90

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2CE04502006

 

21.2

 

2

 

88.3

116.7

125

 

125

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2CE045005253

 

4.0

 

1

 

11.0

25.7

40

 

40

 

 

208-3-60

2CE045007253

5.0

5.6

 

1

 

15.6

25.7

40

 

40

 

 

2CE04501025

8.0

 

1

 

22.1

34.0

40

 

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

048

 

 

2CE04501525

 

11.9

 

2

 

33.1

47.5

50

 

50

 

 

2CE04502025

 

15.9

 

2

 

44.2

61.4

70

 

70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2CE045005253

 

5.3

 

1

 

12.7

25.7

40

 

40

 

 

230-3-60

2CE045007253

5.0

7.5

 

1

 

18.0

28.8

40

 

40

 

 

2CE04501025

10.6

 

1

 

25.5

38.0

40

 

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2CE04501525

 

15.9

 

2

 

38.2

54.0

60

 

60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2CE04502025

 

21.2

 

2

 

51.0

70.0

70

 

70

 

 

 

2CE045007463

 

6.8

 

1

 

8.2

13.2

20

 

20

 

 

460-3-60

2CE045010463

2.2

10.1

 

1

 

12.1

17.9

20

 

20

 

 

2CE045015463

13.6

 

1

 

16.4

23.2

25

 

25

 

 

 

 

 

 

 

 

 

 

2CE045020463

 

19.5

 

2

 

23.5

32.1

35

 

35

 

 

 

2CE04501058

 

10.6

 

1

 

10.2

15.5

20

 

20

 

 

575-3-60

 

2.2

 

 

 

 

 

 

 

 

 

 

 

2CE04501558

15.9

 

1

 

15.3

21.9

25

 

25

 

 

 

2CE04502058

 

21.2

 

2

 

20.4

28.2

30

 

30

1.Dual element, time delay type.

2.Standard circuit breakers may be used in Canada and on applications over 60 amps where the heaters are separately fused.

3.These electric heaters DO NOT include a fuse box. If a fuse box is required to meet a local code (e.g. Chicago), the following fuse block accessories are available for field installation (see Table 19).

TABLE 18: ELECTRIC HEAT CORRECTION FACTORS

NOMINAL VOLTAGE

VOLTAGE

kW CAP. MULTIPLIER

208

208

1.00

240

230

0.92

480

460

0.92

600

575

0.92

TABLE 19: FUSE BLOCK ACCESSORY

PART NUMBER

VOLTS

2FB04700425

208/240 Volts

2FB04700546

460 Volts

18

Unitary Products Group

Image 18
Contents General Flexible Easy to Install Single Package UnitsTechnical Guide Sunline Plus AIR-COOLED AIR Conditioners FeaturingTable of Contents Features DescriptionFACTORY-INSTALLED Options FIELD-INSTALLED AccessoriesSunline Plus Component Location Sound Power RATINGS1 Capacity Ratings Cooling / Electric HeatingCapacity Ratings Cooling / GAS Heating Physical Data Basic Unit Models DEE/DEGCooling Capacities 3 TON DEE / DEG036 AIR on Temperature of AIR on Condenser CoilTotal Power Evaporator Sensible CAPACITY1, MBHCooling Capacities 4 TON DEE / DEG048 Cooling Capacities 5 TON DEE / DEG060 Model AIR Available External Static Pressure IWG3 Flow CFM RPM Watts036-21411-002-A-0204 2500 1059 1560 1077 1590 1095 1630 LOW Static ResistancesMED RESISTANCE, IWG Description CFMBasic Unit W/ DIRECT-DRIVE Electrical Data MOTOR1 AdjustableMotor and Drive Data BELT-DRIVE Blower BeltBasic Unit W/ BELT-DRIVE Electrical Data Electrical Data COOLING/ELECTRIC Heat W/ Direct Drive DEE036 Nominal Voltage Fuse Block AccessoryElectric Heat Correction Factors Part Number VoltsDEE Supply Model Stages SIZE1 Motor Ampacity Amps Breaker FLAElectrical Data COOLING/ELECTRIC Heat W/ Belt Drive DEE036 Electrical Data COOLING/ELECTRIC Heat W/ Belt Drive DEE060 DEE Supply Model StagesMotor Ampacity Comprssorr Elayand COOLING/HEATINGELECTRONICTHERMOSTAT Singlestage Hole Knockout Size DIAUnit Dimensions DEG 3, 4, & 5 TON DEE/DEG Unit Clearances DEE/DEG Dimensions Rear View 3, 4, & 5 TON Detail B Unit Dimensions with DAMPER/RAINHOOD Roof Curb Dimensions DEE & DEG 3, 4, & 5 TON Unit Weights Unit Corner WeightsTypical Applications Mechanical Specifications Electric Heating Section DEE Models Unit Operating CharacteristicsGAS Heating Section DEG Models Electrical RequirementsOther PRE-ENGINEERED Accessories AVAIL- Able Other Factory Installed OptionsOptional Outdoor AIR

D1EG, D1EE036 specifications

The York D1EE036 and D1EG are two models of high-performance direct expansion (DX) rooftop air conditioning units designed for commercial applications. These units are known for their efficiency, reliability, and advanced technology.

The D1EE036 model is particularly recognized for its energy efficiency, featuring a high-efficiency scroll compressor. This compressor operates at lower energy consumption levels while providing consistent cooling performance. The unit is equipped with variable speed technology, which adjusts the compressor's speed according to the cooling demand. This feature not only optimizes energy use but also minimizes the sound levels during operation, making it suitable for noise-sensitive environments such as hospitals and schools.

On the other hand, the D1EG model is designed for versatility and offers a range of custom configuration options. It incorporates advanced controls that allow for integration with building management systems, enabling users to monitor and manage their HVAC systems remotely. The D1EG is also notable for its robust construction, with weather-resistant enclosures that ensure durability and longevity in various environmental conditions.

Both models feature an advanced microprocessor control system that provides precise temperature control and enhances overall system efficiency. These controls allow for multiple unit configurations, including staged cooling, which further contributes to energy savings. Additionally, both units come equipped with high-efficiency filters that improve indoor air quality by trapping dust, pollen, and other airborne particles.

From a technological standpoint, the York D1EE036 and D1EG models support environmentally friendly refrigerants, which comply with the latest regulations for reducing ozone depletion potential. The use of these refrigerants not only helps in meeting regulatory requirements but also aligns with global sustainability goals.

In summary, the York D1EE036 and D1EG rooftop units are engineered to deliver excellent performance, adaptability, and energy efficiency for commercial settings. Their combination of innovative technologies, environmentally conscious design, and advanced control features make them a compelling choice for businesses looking to enhance their HVAC systems while reducing operational costs. Whether requiring quiet operation or robust configurability, these units offer solutions that cater to diverse commercial needs.