TABLE 6: COOLING CAPACITIES - 4 TON (DEE / DEG048)

AIR ON

 

 

 

 

 

 

TEMPERATURE OF AIR ON CONDENSER COIL

 

 

 

 

 

 

 

 

 

 

 

85°F

 

 

 

 

 

 

 

 

 

95°F

 

 

 

 

 

EVAPORATOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SENSIBLE CAPACITY1, MBH

 

 

 

 

 

SENSIBLE CAPACITY1, MBH

 

COIL

 

TOTAL

POWER

 

 

TOTAL

POWER

 

 

 

 

 

ENTERING DRY BULB, °F

 

 

 

ENTERING DRY BULB, °F

 

 

 

 

CAP.1

INPUT2

 

 

CAP.1

INPUT2

 

 

 

CFM

 

WB

MBH

kW

86

83

 

80

77

74

71

68

MBH

kW.

 

86

83

 

80

77

74

71

68

 

 

°F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

72

64

3.9

45

39

 

33

27

21

-

-

60

4.2

 

44

38

 

32

26

20

-

-

2000

 

67

57

3.8

55

49

 

43

37

31

25

19

53

4.1

 

53

47

 

41

35

29

23

17

 

62

54

3.8

54

54

 

53

47

41

35

29

50

4.0

 

50

50

 

50

44

38

32

26

 

 

 

 

 

 

 

57

54

3.8

54

54

 

54

48

42

36

30

50

4.0

 

50

50

 

50

46

40

34

28

 

 

72

62

3.9

42

36

 

31

25

20

-

-

58

4.2

 

41

35

 

30

24

19

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1800

 

67

55

3.8

51

46

 

40

35

30

24

19

52

4.1

 

50

44

 

39

34

28

23

18

 

 

62

52

3.8

52

52

 

49

44

39

33

28

49

4.1

 

49

49

 

47

42

37

31

26

 

 

57

52

3.8

52

52

 

51

45

40

35

29

49

4.1

 

49

49

 

49

44

38

33

27

 

 

72

59

3.9

38

33

 

29

24

19

-

-

57

4.2

 

38

33

 

28

23

18

-

-

1600

 

67

54

3.8

48

43

 

38

33

29

24

19

52

4.2

 

47

42

 

37

32

28

23

18

 

 

62

50

3.7

50

50

 

46

41

36

32

27

47

4.1

 

47

47

 

45

40

35

31

26

 

 

57

50

3.7

50

50

 

47

42

38

33

28

47

4.1

 

47

47

 

46

41

37

32

27

 

 

72

58

3.8

35

31

 

27

23

18

-

-

55

4.2

 

34

30

 

26

22

17

-

-

1400

 

67

52

3.8

44

39

 

35

31

27

22

18

49

4.2

 

42

38

 

34

30

26

21

17

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

62

49

3.7

48

47

 

43

39

34

30

26

46

4.1

 

46

45

 

42

37

33

29

25

 

 

57

49

3.7

49

48

 

44

40

36

31

27

46

4.1

 

46

46

 

43

38

34

30

26

 

 

72

57

3.8

32

29

 

25

21

17

-

-

53

4.2

 

31

28

 

24

20

16

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1200

 

67

50

3.8

40

36

 

32

29

25

21

17

47

4.2

 

38

35

 

31

27

23

20

16

 

 

62

48

3.7

47

44

 

40

36

33

29

25

45

4.1

 

45

42

 

38

34

31

27

23

 

 

57

48

3.7

48

45

 

41

37

34

30

26

45

4.1

 

45

43

 

39

35

32

28

24

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AIR ON

 

 

 

 

 

 

TEMPERATURE OF AIR ON CONDENSER COIL

 

 

 

 

 

 

 

 

 

 

 

105°F

 

 

 

 

 

 

 

 

 

115°F

 

 

 

 

 

EVAPORATOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SENSIBLE CAPACITY1, MBH

 

 

 

 

 

SENSIBLE CAPACITY1, MBH

 

COIL

 

TOTAL

POWER

 

 

TOTAL

POWER

 

 

 

 

 

ENTERING DRY BULB, °F

 

 

 

ENTERING DRY BULB, °F

 

 

 

 

CAP.1

INPUT2

 

 

CAP.1

INPUT2

 

 

 

CFM

 

WB

MBH

kW.

86

83

 

80

77

74

71

68

MBH

kW.

 

86

83

 

80

77

74

71

68

 

 

°F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

72

56

4.7

42

36

 

30

25

19

-

-

53

5.2

 

41

35

 

29

23

17

-

-

2000

 

67

50

4.6

50

45

 

39

33

28

22

16

47

5.1

 

47

44

 

38

32

26

20

14

 

62

47

4.5

47

47

 

47

41

35

29

23

44

5.0

 

44

44

 

44

38

32

26

20

 

 

 

 

 

 

 

57

47

4.5

47

47

 

47

44

38

32

26

44

5.0

 

44

44

 

44

42

36

30

24

 

 

72

54

4.7

39

34

 

29

23

17

-

-

51

5.1

 

38

33

 

27

22

17

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1800

 

67

49

4.6

47

43

 

37

32

27

21

16

46

5.1

 

45

41

 

36

31

25

20

14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

62

46

4.5

46

46

 

45

40

34

29

23

43

5.0

 

43

43

 

43

37

32

26

21

 

 

57

46

4.5

46

46

 

46

42

36

31

26

43

5.0

 

43

43

 

43

40

34

29

24

 

 

72

53

4.7

36

31

 

27

22

17

-

-

49

5.1

 

35

30

 

25

21

16

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1600

 

67

48

4.6

45

40

 

35

31

26

21

16

44

5.1

 

43

39

 

34

29

24

19

15

 

 

62

44

4.6

44

44

 

43

38

33

29

24

41

5.0

 

41

41

 

41

36

31

26

22

 

 

57

44

4.5

44

44

 

44

39

34

30

25

41

5.0

 

41

41

 

41

37

32

28

23

 

 

72

51

4.7

33

29

 

25

21

16

-

-

48

5.1

 

32

28

 

24

20

15

-

-

1400

 

67

46

4.6

41

37

 

33

28

24

20

16

43

5.0

 

40

35

 

31

27

23

19

14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

62

43

4.5

43

42

 

40

36

31

27

23

40

5.0

 

40

40

 

38

34

30

25

21

 

 

57

43

4.5

43

43

 

41

37

32

28

24

40

5.0

 

40

40

 

39

35

31

26

22

 

 

72

50

4.7

30

27

 

23

19

16

-

-

47

5.1

 

30

26

 

22

18

15

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1200

 

67

44

4.6

37

33

 

30

26

22

19

15

42

5.0

 

36

32

 

29

25

21

18

14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

62

42

4.5

42

41

 

37

33

29

26

22

39

5.0

 

39

39

 

35

32

28

24

21

 

 

57

42

4.5

42

41

 

38

34

30

27

23

39

5.0

 

39

39

 

36

33

29

25

22

1.These capacities are gross ratings. For net capacity, determine the kW of the supply air blower motor from Table 9 or 11, multiply this value by 3.425 MBH/kW to determine the motor heat, and deduct this heat from the gross capacity of the unit.

2.These ratings include the compressor and the condenser fan motors but not the supply air blower motor. The total condenser fan motor power input is 0.36kW. Refer to Tables 9 or 11 for the kW of the supply air blower motor.

NOMINAL RATING

ALL SENSIBLE CAPACITY

Unitary Products Group

9

Image 9
Contents Technical Guide Sunline Plus AIR-COOLED AIR Conditioners Flexible Easy to Install Single Package UnitsGeneral FeaturingTable of Contents Description FeaturesFIELD-INSTALLED Accessories FACTORY-INSTALLED OptionsSunline Plus Component Location Sound Power RATINGS1 Capacity Ratings Cooling / Electric HeatingCapacity Ratings Cooling / GAS Heating Models DEE/DEG Physical Data Basic UnitTotal Power AIR on Temperature of AIR on Condenser CoilCooling Capacities 3 TON DEE / DEG036 Evaporator Sensible CAPACITY1, MBHCooling Capacities 4 TON DEE / DEG048 Cooling Capacities 5 TON DEE / DEG060 Flow CFM RPM Watts Model AIR Available External Static Pressure IWG3036-21411-002-A-0204 2500 1059 1560 1077 1590 1095 1630 MED Static ResistancesLOW RESISTANCE, IWG Description CFMMotor and Drive Data BELT-DRIVE Blower MOTOR1 AdjustableBasic Unit W/ DIRECT-DRIVE Electrical Data BeltBasic Unit W/ BELT-DRIVE Electrical Data Electrical Data COOLING/ELECTRIC Heat W/ Direct Drive DEE036 Electric Heat Correction Factors Fuse Block AccessoryNominal Voltage Part Number VoltsAmps Breaker FLA DEE Supply Model Stages SIZE1 Motor AmpacityElectrical Data COOLING/ELECTRIC Heat W/ Belt Drive DEE036 Electrical Data COOLING/ELECTRIC Heat W/ Belt Drive DEE060 DEE Supply Model StagesMotor Ampacity Comprssorr Elayand COOLING/HEATINGELECTRONICTHERMOSTAT Singlestage Size DIA Hole KnockoutUnit Dimensions DEG 3, 4, & 5 TON DEE/DEG Unit Clearances DEE/DEG Dimensions Rear View 3, 4, & 5 TON Detail B Unit Dimensions with DAMPER/RAINHOOD Unit Corner Weights Roof Curb Dimensions DEE & DEG 3, 4, & 5 TON Unit WeightsTypical Applications Mechanical Specifications GAS Heating Section DEG Models Unit Operating CharacteristicsElectric Heating Section DEE Models Electrical RequirementsOther PRE-ENGINEERED Accessories AVAIL- Able Other Factory Installed OptionsOptional Outdoor AIR

D1EG, D1EE036 specifications

The York D1EE036 and D1EG are two models of high-performance direct expansion (DX) rooftop air conditioning units designed for commercial applications. These units are known for their efficiency, reliability, and advanced technology.

The D1EE036 model is particularly recognized for its energy efficiency, featuring a high-efficiency scroll compressor. This compressor operates at lower energy consumption levels while providing consistent cooling performance. The unit is equipped with variable speed technology, which adjusts the compressor's speed according to the cooling demand. This feature not only optimizes energy use but also minimizes the sound levels during operation, making it suitable for noise-sensitive environments such as hospitals and schools.

On the other hand, the D1EG model is designed for versatility and offers a range of custom configuration options. It incorporates advanced controls that allow for integration with building management systems, enabling users to monitor and manage their HVAC systems remotely. The D1EG is also notable for its robust construction, with weather-resistant enclosures that ensure durability and longevity in various environmental conditions.

Both models feature an advanced microprocessor control system that provides precise temperature control and enhances overall system efficiency. These controls allow for multiple unit configurations, including staged cooling, which further contributes to energy savings. Additionally, both units come equipped with high-efficiency filters that improve indoor air quality by trapping dust, pollen, and other airborne particles.

From a technological standpoint, the York D1EE036 and D1EG models support environmentally friendly refrigerants, which comply with the latest regulations for reducing ozone depletion potential. The use of these refrigerants not only helps in meeting regulatory requirements but also aligns with global sustainability goals.

In summary, the York D1EE036 and D1EG rooftop units are engineered to deliver excellent performance, adaptability, and energy efficiency for commercial settings. Their combination of innovative technologies, environmentally conscious design, and advanced control features make them a compelling choice for businesses looking to enhance their HVAC systems while reducing operational costs. Whether requiring quiet operation or robust configurability, these units offer solutions that cater to diverse commercial needs.