York D1EE036, D1EG warranty Table of Contents

Page 2

036-21411-002-A-0204

TABLE OF CONTENTS

DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 FACTORY-INSTALLED OPTIONS . . . . . . . . . . . . . . 4 FIELD-INSTALLED ACCESSORIES. . . . . . . . . . . . . 4 MECHANICAL SPECIFICATIONS . . . . . . . . . . . . . 30

 

LIST OF FIGURES

 

Fig.

Pg.

1

SUNLINE PLUS COMPONENT LOCATION

. . 5

2

POWER SUPPLY, POWER WIRING THREE PHASE 22

3

CONTROL WIRING - COOLING ONLY

. 22

4

CONTROL WIRING- COOLING & HEATING

 

 

MULTI-STAGE

. 22

5

POWER SUPPLY, POWER WIRING SINGLE

 

 

PHASE

. 22

6

CONTROL WIRING - COOLING/HEATING

 

 

(24 VOLT THERMOSTAT)

. 22

7

CONTROL WIRING - COOLING/HEATING

 

 

(ELECTRONIC THERMOSTAT)

. 23

8

UNIT DIMENSIONS WITH ECONOMIZER

 

 

RAINHOOD

. 23

9

UNIT DIMENSIONS DEE 3, 4, & 5 TON

. 24

10

ACCESS PANELS AND DISCONNECT

. 24

11

UNIT DIMENSIONS DEG 3, 4, & 5 TON

. 25

12

DEE/DEG DIMENSIONS REAR VIEW -

 

 

3, 4, & 5 TON

. 26

13

DETAIL B UNIT DIMENSIONS WITH DAMPER/

 

 

RAINHOOD

. 27

14

UNIT & CURB APPLICATION

. 27

15

ROOF CURB DIMENSIONS DEE & DEG

 

 

3, 4, & 5 TON

. 28

16

CENTER OF GRAVITY

. 28

17

TYPICAL APPLICATIONS

. 29

18

TYPICAL ROOF TOP INSTALLATION

. 29

 

LIST OF TABLES

 

Tbl.

Pg.

1 CAPACITY RATINGS - COOLING / ELECTRIC HEATING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

2 CAPACITY RATINGS - COOLING / GAS HEATING . . . 7

3 SOUND POWER RATINGS . . . . . . . . . . . . . . . . . . . . . . 7 4 PHYSICAL DATA - BASIC UNIT . . . . . . . . . . . . . . . . . . 8 5 COOLING CAPACITIES - 3 TON (DEE / DEG036) . . . . 9 6 COOLING CAPACITIES - 4 TON (DEE / DEG048) . . . 10 7 COOLING CAPACITIES - 5 TON (DEE / DEG060) . . . 11

8 SUPPLY AIR BLOWER PERFORMANCE -DEE/ DEG036 W/ BELT DRIVE & SIDE DUCT . . . . . . . . . . 12

9 SUPPLY AIR BLOWER PERFORMANCE -DEE/ DEG048 W/ BELT DRIVE & SIDE DUCT . . . . . . . . . . 13

10 SUPPLY AIR BLOWER PERFORMANCE -DEE/ DEG060 W/ BELT DRIVE & SIDE DUCT . . . . . . . . . . 14

11 SUPPLY AIR BLOWER PERFORMANCE - DEE/ DEG036-060 W/ DIRECT DRIVE . . . . . . . . . . . . . . . . . 15

12 STATIC RESISTANCES. . . . . . . . . . . . . . . . . . . . . . . . 15

13MOTOR AND DRIVE DATA - BELT-DRIVE BLOWER 16

14BASIC UNIT W/ DIRECT-DRIVE ELECTRICAL DATA 16

15

BASIC UNIT W/ BELT-DRIVE ELECTRICAL DATA . .

17

16

ELECTRICAL DATA COOLING/ELECTRIC HEAT

 

 

W/ DIRECT DRIVE DEE036

18

17

ELECTRICAL DATA COOLING/ELECTRIC HEAT

 

 

W/ DIRECT DRIVE DEE048

19

18

ELECTRIC HEAT CORRECTION FACTORS

19

19

FUSE BLOCK ACCESSORY

19

20

ELECTRICAL DATA COOLING/ELECTRIC HEAT

 

 

W/ DIRECT DRIVE DEE060

20

21

ELECTRICAL DATA COOLING/ELECTRIC HEAT

 

 

W/ BELT DRIVE DEE036 & 048

21

22

ELECTRICAL DATA COOLING/ELECTRIC HEAT

 

 

W/ BELT DRIVE DEE060

22

23

UTILITIES ENTRY DATA

25

24

DEE/DEG UNIT CLEARANCES

26

25

ACCESSORY’S WEIGHT

29

26

UNIT WEIGHTS

29

2

Unitary Products Group

Image 2
Contents General Flexible Easy to Install Single Package UnitsTechnical Guide Sunline Plus AIR-COOLED AIR Conditioners FeaturingTable of Contents Features DescriptionFACTORY-INSTALLED Options FIELD-INSTALLED AccessoriesSunline Plus Component Location Capacity Ratings Cooling / GAS Heating Sound Power RATINGS1Capacity Ratings Cooling / Electric Heating Physical Data Basic Unit Models DEE/DEGCooling Capacities 3 TON DEE / DEG036 AIR on Temperature of AIR on Condenser CoilTotal Power Evaporator Sensible CAPACITY1, MBHCooling Capacities 4 TON DEE / DEG048 Cooling Capacities 5 TON DEE / DEG060 Model AIR Available External Static Pressure IWG3 Flow CFM RPM Watts036-21411-002-A-0204 2500 1059 1560 1077 1590 1095 1630 LOW Static ResistancesMED RESISTANCE, IWG Description CFMBasic Unit W/ DIRECT-DRIVE Electrical Data MOTOR1 AdjustableMotor and Drive Data BELT-DRIVE Blower BeltBasic Unit W/ BELT-DRIVE Electrical Data Electrical Data COOLING/ELECTRIC Heat W/ Direct Drive DEE036 Nominal Voltage Fuse Block AccessoryElectric Heat Correction Factors Part Number VoltsDEE Supply Model Stages SIZE1 Motor Ampacity Amps Breaker FLAElectrical Data COOLING/ELECTRIC Heat W/ Belt Drive DEE036 Motor Ampacity Electrical Data COOLING/ELECTRIC Heat W/ Belt Drive DEE060DEE Supply Model Stages Comprssorr Elayand COOLING/HEATINGELECTRONICTHERMOSTAT Singlestage Hole Knockout Size DIAUnit Dimensions DEG 3, 4, & 5 TON DEE/DEG Unit Clearances DEE/DEG Dimensions Rear View 3, 4, & 5 TON Detail B Unit Dimensions with DAMPER/RAINHOOD Roof Curb Dimensions DEE & DEG 3, 4, & 5 TON Unit Weights Unit Corner WeightsTypical Applications Mechanical Specifications Electric Heating Section DEE Models Unit Operating CharacteristicsGAS Heating Section DEG Models Electrical RequirementsOptional Outdoor AIR Other PRE-ENGINEERED Accessories AVAIL- AbleOther Factory Installed Options

D1EG, D1EE036 specifications

The York D1EE036 and D1EG are two models of high-performance direct expansion (DX) rooftop air conditioning units designed for commercial applications. These units are known for their efficiency, reliability, and advanced technology.

The D1EE036 model is particularly recognized for its energy efficiency, featuring a high-efficiency scroll compressor. This compressor operates at lower energy consumption levels while providing consistent cooling performance. The unit is equipped with variable speed technology, which adjusts the compressor's speed according to the cooling demand. This feature not only optimizes energy use but also minimizes the sound levels during operation, making it suitable for noise-sensitive environments such as hospitals and schools.

On the other hand, the D1EG model is designed for versatility and offers a range of custom configuration options. It incorporates advanced controls that allow for integration with building management systems, enabling users to monitor and manage their HVAC systems remotely. The D1EG is also notable for its robust construction, with weather-resistant enclosures that ensure durability and longevity in various environmental conditions.

Both models feature an advanced microprocessor control system that provides precise temperature control and enhances overall system efficiency. These controls allow for multiple unit configurations, including staged cooling, which further contributes to energy savings. Additionally, both units come equipped with high-efficiency filters that improve indoor air quality by trapping dust, pollen, and other airborne particles.

From a technological standpoint, the York D1EE036 and D1EG models support environmentally friendly refrigerants, which comply with the latest regulations for reducing ozone depletion potential. The use of these refrigerants not only helps in meeting regulatory requirements but also aligns with global sustainability goals.

In summary, the York D1EE036 and D1EG rooftop units are engineered to deliver excellent performance, adaptability, and energy efficiency for commercial settings. Their combination of innovative technologies, environmentally conscious design, and advanced control features make them a compelling choice for businesses looking to enhance their HVAC systems while reducing operational costs. Whether requiring quiet operation or robust configurability, these units offer solutions that cater to diverse commercial needs.