HP 2995 manual Connect AC Line Cord, Close and Seal the Enclosure, Connect to AC Power

Page 11

Figure 8 - Connection diagram for Bodine 230V inverter-duty motors.

Figure 9 - Connection diagram for Bodine 230/460V inverter-duty motors wired for 230V operation.

Table 3 - Direction of Bodine motor driveshaft rotation, viewing end of driveshaft, when connected per the diagrams at the left and with control set for “forward” direction

Bodine Motor Type

Direction

30R2BEPP

CCW

30R4BEPP

CCW

30R2BEPP-D3

CW

30R4BEPP-D3

CW

30R2BEPP-D4

CCW

30R4BEPP-3N

CCW

34R6BEPP-Z2

CCW

34R6BEPP-Z3

CCW

34R6BEPP-Z4

CW

34R4BFPP-E1

CCW

34R4BFPP-E2

CW

34R4BFPP-E3

CCW

34R4BFPP-E4

CW

34R6BFPP

CW

34R6BFYP

CW

42R6BFPP

CCW

42R6BFPP-GB

CW

42R6BFPP-F1

CW

42R6BFPP-F2

CCW

42R6BFPP-F3

CW

42R6BFPP-5N

CCW

42R6BFPP-5H

CCW

48R5BFYP

CCW

Step 6 – Connect AC Line Cord

A cord should be used for the AC power connection in order to properly seal against water through the liquid tight fitting. Connect the hot side of the line to “L1” and the neutral side to “L2.” Connect earth ground to the terminal labeled “CHASSIS GROUND.” Tighten the barrier terminal block screws to 6 lb-in.

Step 7 – Close and Seal the Enclosure

Close the hinged cover and tighten the four screws, one at each corner.

Step 8 - Connect to AC Power

After all other connections are made and the control is closed, connect the AC line cord to the AC power supply.

11

Image 11
Contents Phase AC Motor Speed Control Quick Reference Table of Contents Electrical Ratings Product SpecificationsImportant Safety Precautions Examine before installation InstallationMount Control Choose a Suitable Location Connection Preliminary SetupPage Electrical connections for Model Connect the MotorClose and Seal the Enclosure Connect to AC PowerConnect AC Line Cord Check System Before Starting OperationOperate the Inverter Adjust Trim Pots OptionalMIN Minimum Speed DEC/B Deceleration with 60 Hz or 120 Hz configuration CL Current Limit with I2t Shutdown Abnormality Check Point Countermeasure TroubleshootingOperating LED LED Flash Corrective Type HPP-5337E4 AC Motor Speed Control, Model number Declaration of ConformityBodine Limited Warranty