Figure 8 - Connection diagram for Bodine 230V inverter-duty motors.
Figure 9 - Connection diagram for Bodine 230/460V inverter-duty motors wired for 230V operation.
Table 3 - Direction of Bodine motor driveshaft rotation, viewing end of driveshaft, when connected per the diagrams at the left and with control set for “forward” direction
Bodine Motor Type | Direction |
30R2BEPP | CCW |
30R4BEPP | CCW |
CW | |
CW | |
CCW | |
CCW | |
CCW | |
CCW | |
CW | |
CCW | |
CW | |
CCW | |
CW | |
34R6BFPP | CW |
34R6BFYP | CW |
42R6BFPP | CCW |
CW | |
CW | |
CCW | |
CW | |
CCW | |
CCW | |
48R5BFYP | CCW |
Step 6 – Connect AC Line Cord
A cord should be used for the AC power connection in order to properly seal against water through the liquid tight fitting. Connect the hot side of the line to “L1” and the neutral side to “L2.” Connect earth ground to the terminal labeled “CHASSIS GROUND.” Tighten the barrier terminal block screws to 6
Step 7 – Close and Seal the Enclosure
Close the hinged cover and tighten the four screws, one at each corner.
Step 8 - Connect to AC Power
After all other connections are made and the control is closed, connect the AC line cord to the AC power supply.